Instruction Manual for DURATECH models including: DVP050 Vision Pro Moonlight, DVP050, Vision Pro Moonlight, Pro Moonlight, Moonlight

PRO Manual EN

Duratech |


File Info : application/pdf, 24 Pages, 1.37MB

PDF preview unavailable. Download the PDF instead.

1678704523PRO-Manual EN
Manual
DVP050 DVP100 DVP170

Visit www.duratech.be for other available languages

Pro

06-03-23

2

Table of contents
Technical specifications Remarks Box contents Installation instructions Installation specialties Wiring instructions setup 1 Wiring instructions setup 2 Wiring remarks Synchronizing Color programs Troubleshooting

Page 4 Page 5-6 Page 7 Page 10-11 Page 12-13 Page 14-15 Page 16-17 Page 18-19 Page 20 Page 21 Page 22
3

ENG

Technical specifications

Lamp Type DVP050-RGBW DVP100-RGBW DVP170-RGBW

Description
All colours and Tunable white
All colours and Tunable white
All colours and Tunable white

Voltage Power Color temp

10-14 VAC 33 W

n.a.

Luminous flux*
1200 lm

10-14 VAC 85 W

n.a.

3500 lm

10-14 VAC 180 W

n.a.

7000 lm

(*) Propulsion systems remains a tolerance of +/- 10% on luminous flux measurements @ 25°C ; 12VAC

For operation only with a safety isolation transformer

Minimum input voltage: (at lamp terminals)
Nominal input voltage: (at lamp terminals)
Maximum input voltage: (at lamp terminals)

10 VAC 50/60 Hz 12 VAC 50/60 Hz 14 VAC 50/60 Hz

IEC Protection Class III

Operation on DC voltages is NOT allowed

Maximum water temperature: +40°C
Lamps have to be kept out of ice zones

Ingress protection rate:

IP68
measured at 3m max depth = 3m

4

ENG

Remarks

Water conditions
Prevent damage to your pool lamps and wires due to unstable water conditions. Your local government may have enacted guidelines for your pool water conditions to apply by. If not we strongly advise the following parameter specifications to be applied:

pH level Free Chlorine Combined chlorine Water temperature

6,8 - 7,6 max. 3ppm max. 1 ppm max +40°C and lamps need to be kept out of ice zones

Always adhere to the instructions provided by your chemical brand/supplier for the correct use and application of pool chemicals.

Salt water pools, or pools fitted with a salt water chlorine generator contain salt in the pool water. Salt is a corrosive material. Overdosage and/or consistent levels of salt increase the possibility of deterioration of your pool lamps and cables. As a rule of thumb, a concentration of 35gr/l salt can be accepted when pH values are between 7,2-7,4. In any case, we urge proper use, care and maintenance of your installation, in order to minimize the effect of corrosion and deterioration.

Please be aware that pool lamps and cables with defects caused due to abnormalities in the water condition are not covered by our factory warranty.

5

Installation/maintenance The luminaire is maintenance free If the luminaire needs to be replaced, it needs to be completely removed from the water
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively
! replaced by the manufacturer or his service agent or a similar qualified person in order
to avoid hazard VISION Pro Pool lamps must be completely submerged into water during operation.
! Fixing the lamps with adhesives or silicone kit into a niche is not allowed
Not following these instructions, will void warranty.
6

ENG

Box contents

VISION Pro lamp (50, 100 or 170 mm)

Connection Kit*

2m Cable**

Manual

Retrofit Kit (only for 170mm models)

* Lamp type ** DVP050-RGBW
DVP100-RGBW
DVP170-RGBW

Connection kit 513-0480 ; 1 washer for fixnut ; blue cable gasket 513-0636 ; 2 washers for fixnut ; orange cable gasket 513-0393 ; 3 washers for fixnut; green cable gasket

Cable 1 mm2 1,5 mm2 2,5 mm2

7

Installation instructions
Installing faceplate
Toolset ( not included ) Contact your local distributor for a toolset (513-0151)
Lamp
Face Plate
8

ENG

Installation instructions
Installing connector DVP050-RGBW
2m Cable

DVP100-RGBW

Washer Fix Nut

Silicone Gasket Connector

!
Installation: Page 10 & 11

DVP170-RGBW

9

Connector installation

1

2

3

10

ENG

4

5

6

11

Installation specialties
DVP050 & PZA-WG For installations with DVP050 & PZA-WG-S or PZA-WG-G: Please make sure to only use 1 silicone washer for the Fix nut
PZA-WG-G

Fix nut

12

ENG

DVP050 Removal tool When DVP050 needs to be removed from the PZA-WG wall conduits, a special tool is needed (513-0491)* 1. Insert the tool over the lamp,
straight into the wall conduit 2. Twist the tool counter clockwise
the lamp should be snapped into the 3 hooks of the tool 3. Pull the lamp straight out of the wall conduit
* Available separately
13

Wiring instructions Setup 1
For new installations Each lamp is connected to the transformer by a separate cable
Pool
Pool house

SELECT CABLE SECTION & MAXIMUM LENGTH

2m cable included in lamp package Separate cable ( not included )

! Always use a toroïdal transformer

14

ENG

LAMP TYPE

SELECT CABLE SECTION & MAXIMUM LENGTH
1,5mm2 2,5mm2 4,0mm2 6,0mm2 10mm2 VA TRANSFORMER (12VAC)*

DVP050-RGBW

23m 35m 60m 95m 155m

43 VA

DVP100-RGBW

9m 15m 24m 35m 60m

111 VA

DVP170-RGBW

4m 7m 11m 17m 29m

234 VA

STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE
* The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps. These cable lenghts are calculated with worst case voltage drops in the electrical wiring.
15

Wiring instructions Setup 2
For existing or other installations All lamps are connected to the transformer via 1 cable

Pool

Pool house

SELECT CABLE SECTION & MAXIMUM LENGTH

2m cable included in lamp package Separate cable ( not included )

! Always use a toroïdal transformer

16

ENG

LAMP TYPE DVP050-RGBW DVP100-RGBW DVP170-RGBW

SELECT CABLE SECTION & MAXIMUM LENGTH
QTY 2,5mm2 4,0mm2 6,0mm2 10mm2

VA TRANSFORMER (12VAC)

1

35m

60m

95m

155m

43

2

18m

30m

48m

78m

86

3

12m

20m

32m

52m

129

4

9m

10m

24m

39m

172

1

15m

24m

35m

60m

111

2

8m

12m

18m

30m

221

3

5m

8m

12m

20m

332

4

4m

6m

9m

15m

442

1

7m

11m

17m

29m

234

2

4m

6m

9m

15m

468

3

2m

4m

6m

10m

702

4

2m

3m

4m

7m

936

STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE
17

Wiring remarks

For installations with LINK Controller or LINK Master
Third party equipment such as frequency inverters and electric motors can generate excessive noise on the 230VAC / 400VAC power line.
This noise might be injected into the adjacent 12VAC power line and disturb the power line communication towards the VISION Pro RGBW lights.

To prevent this, please take care of the following:

!

Keep 230VAC / 400VAC power line cables at least 50cm separated over their full length from the 12VAC power line towards any RGB lights

!

Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable trays

18

ENG

Pool

Pool house

12VAC to lamps

(**)
230VAC

Min. 50cm 230VAC / 400VAC to third party equipment

(**) Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable trays

19

Synchronizing
With LinkTouch + LINK Controller (PLP-REM or PLP-REM-350)* + LINK Master (DLM450 or DLM600)
First make sure the LinkTouch is paired (see manual LinkTouch) Turn the lamps on and spin the color wheel on the LinkTouch until the lamps react. If the lamps do not react, turn them off and back on untill they react to the color wheel. As soon as the lamps follow the color wheel: wait 1 minute. The lamps are now synced.
With Transmitter + LINK Controller (PLP-REM or PLP-REM-350)*
Turn the lamps on and push the UP button 10 times. Wait for 20 seconds, then turn the lamps off. Repeat this process until the lamps react to the remote. As soon as the lamps follow the remote: wait 1 minute. The lamps are now synced.
Manual synchronization (without DURALINK control products) 1. Switch ON the 12 VAC line voltage and make sure that all lamps light up. 2. Switch OFF the 12 VAC line voltage and wait for at least 1 minute 3. Switch ON 4. The lamps should now all be on color program 1: Blue
*PLP-REM or PLP-REM-350 need to have firmware V6.7 (29-07-20) or newer
20

ENG

Color programs
RGBW LAMPS

1 DEEP BLUE SEA

Saturated blue

2 DAYLIGHT BLUE

Light blue

3 SUNSET

Slow animation orange - red

4 LOVE IS IN THE AIR 55 FOREST SPRING

Red Green

6 THINK PINK 7 SUNSHINE 8 JUNGLE BEACH 9 VOODOO

Pink Yellow Slow animation blue & green tints Slow animation red & purple tints

10 DISCO

Fast animation lila-pink-peach-yellow-green blue

11 PARTY

Fast animation blue-green-red-pink-yellow-green

12 WARM WHITE

3000K

13 NEUTRAL WHITE 14 SUN WHITE

6000K 10.500K

fixed colors dynamic colors white tints

*all color programs are dimmable if LINK Touch, LINK Controller or LINK Master are used (in PLC mode)

21

Troubleshooting
PROBLEM
. The pool light is flickering
. Several pool lights in the pool show different color programs
. The lamp is flashing red
22

SOLUTION
1. Switch the lamps ON and select Cold white color program 2. Remove the lamp from the water, unscrew the fix nut,
pull back the gasket and the black cable jacket, so you can reach the brass contacts inside the connector block (do not remove the connector block) 3. Measure the voltage at the lamp terminals (while the lamp is still ON) 4. The voltage at the lamp should be at least 10VAC 50/60Hz. If the measured line voltage is below 10VAC:
A. Check the output voltage at the transformator terminals. This voltage should be between 12VAC and 14VAC. Verify that the used transformator VA rating is sufficient for powering all connected lamps
B. If the transformator output voltage is ok, then install a thicker cable between the transformator and the lamp. (wiring instructions p. 14-19)
Make sure that all lamps are connected to the same 12VAC power line. Execute the synchronization as explained on p.20
The lamp is exposed to an overvoltage. Consult an electrician to verify the installation and to make sure the voltage at the lamp side is below 14VAC.

ENG

Declaraction of Conformity
Declarations of conformity covering this product are available for download from the House of Duratech website: www.duratech.be

VISION Moonlight VISION Spectra VISION Adagio Pro VISION Pro VISION Wall Conduits VISION Face Plates VISION Specials

HEAT Hot Splash HEAT Sun Spring HEAT Dura V HEAT Dura Vi HEAT Dura +i HEAT Dura Pro HEAT Accessories

FLOW Inverter FLOW Cartridge Filter

COVER Tube COVER Motor COVER Wall Duct COVER Cable Duct COVER Hanging System

LINK Driver LINK Touch LINK Controller LINK Cover LINK Master LINK Accessoires

23

Contact details
Propulsion Systems bv Dooren 72
1785 Merchtem, Belgium Tel +32 2 461 02 53 www.duratech.be
info@propulsionsystems.be