Instruction Manual for LIGHTWARE models including: Smart IP Driver, IP Driver, Driver

Jens Wäling

Lightware Advanced Room Automation (LARA)

Genelec Smart IP driver for LARA


File Info : application/pdf, 11 Pages, 735.61KB

PDF preview unavailable. Download the PDF instead.

Genelec Smart IP Driver Manual v1.1.0
Genelec Smart IP driver for LARA

Page 2
TABLE OF CONTENTS
1. INTRODUCTION ..................................................................................................................................................... 3 2. INSTALLATION AND CONFIGURATION ................................................................................................................... 3
2.1. INSTALLATION ........................................................................................................................................................... 3 2.2. CONFIGURATION........................................................................................................................................................ 4
2.2.1. Starting LARA, Uploading Configuration ...................................................................................................... 4 3. DASHBOARD CONTENT.......................................................................................................................................... 4 4. DEFINED PARAMETERS .......................................................................................................................................... 4 5. DEFINED EVENTS ................................................................................................................................................... 5
5.1. HEARTBEAT_PRIOD: ................................................................................................................................................... 5 5.2. SPEAKERERROR: ........................................................................................................................................................ 5 5.3. ERROR: .................................................................................................................................................................... 5 5.4. RESPONSERECEIVED: .................................................................................................................................................. 5 5.5. DEFINED STATUS VARIABLES: ....................................................................................................................................... 5 6. DEFINED METHODS ............................................................................................................................................... 7 6.1. PUT, POST, GET, DEL ................................................................................................................................................... 7 6.2. HEARTBEAT ............................................................................................................................................................... 7 6.3. SETMUTE ................................................................................................................................................................. 7 6.4. SETVOLUME.............................................................................................................................................................. 7 6.5. SETPOWERSATE......................................................................................................................................................... 7 6.6. GETDEVICEINFO......................................................................................................................................................... 7 6.7. GETAOIPIDENT ......................................................................................................................................................... 7 6.8. GETAOIPDATA .......................................................................................................................................................... 7 6.9. GETMEASUREMENTDATA ............................................................................................................................................ 8 6.10. GETPROFILELIST ................................................................................................................................................... 8 6.11. SETPROFILEID...................................................................................................................................................... 8 6.12. GETNETWORKCONFIG ........................................................................................................................................... 8 6.13. GETAUDIOINPUTDATA .......................................................................................................................................... 8 6.14. IDENTIFICATION.................................................................................................................................................... 8 6.15. SETLEDINTENSITY ................................................................................................................................................ 8 7. DEFINED RULES IN THE TEST LOGIC MODULE ........................................................................................................ 9 7.1. RULES FOR SETTING PARAMETERS OF THE LOUDSPEAKER:................................................................................ 9 7.2. RULES FOR GETTING DATA FROM THE LOUDSPEAKER ....................................................................................... 10
Genelec Smart IP driver for LARA

Page 3
1. Introduction
Smart IP LARA module is for controlling Genelec Smart IP loudspeakers using REST style communication with a reduced set of HTTP/1.1 protocol. Smart IP API documentation can be downloadad from here: https://www.genelec.com/smart-ip-api
2. Installation and Configuration
2.1. Installation
Minimum equipment requirement for the solution:  Lightware UCX series Universal Matrix Switcher (FW: v2.12.0b3) or UCX-BD series Universal Matrix Switcher (FW: v2.14.0b3) with built DSP  Smart IP device, in this example: Genelec 4410 loudspeaker (FW: 44x0-1.4.0)  Ethernet network switch  Cables
Before you start, please setup Genelec active speaker as an audio device using Smart IP Manager. Further information can be found here: https://www.genelec.com/smart-ip-manager Before uploading any LARA module, or configuration, please download the latest Firmware from https://lightware.com/. Upgrade your UCX series Universal Matrix Switcher and activate LARA. For further information please refer to the user manuals: https://lightware.com/pub/media/lightware/filedownloader/file/UserManual/Taurus_UCX_series_Users_Manual.pdf https://lightware.com/lara/ https://lightware.com/pub/media/lightware/filedownloader/file/User-Manual/LARA_Users_Manual.pdf
Genelec Smart IP driver for LARA

Page 4
2.2. Configuration
2.2.1. Starting LARA, Uploading Configuration
Start a new browser window typing : https://192.168.1.88/lara where the IP address is : UCX series matrix device Choose: UPLOAD CONFIGURATION
For detailed information please find chapter 5.7. Lightware Advanced Room Automation (LARA) in this document: https://lightware.com/pub/media/lightware/filedownloader/file/UserManual/Taurus_UCX_series_Users_Manual.pdf
3. Dashboard Content
The following status indicator is displayed on the Status board in the row of the instance:
 Connection state of the device  Product data ( Device type, FW version )  Power status, Mute status, Volume level, Zone information, Device information
4. Defined parameters
 ipAddressOrHost: The IP address or the host name of the Genelec Smart IP device, hereinafter loudspeaker in this example
 Username: defined in Smart IP Manager  Password: defined in Smart IP Manager  Min / Max Volume level can be defined. These are converted to status variables for future use in the logic module.  Log messages can be enabled in the log section of LARA GUI.
Genelec Smart IP driver for LARA

Page 5
5. Defined Events
5.1. Heartbeat_priod:
This event is dispatched, after every 5000 ms. This means that the dashboard information is refreshed in every five seconds.
5.2. Speakererror:
This event is emitted in case of connection loss between the UCX and the Genelec speaker.
5.3. error:
e.g. Problem in the data transmission, e.g. wrongly set frame delimiter. `errormessage` parameter is defined in this event for the error code.
5.4. responseReceived:
The received string; `string` parameter is defined in this event. It can be used to analyse the content of the response received from the device.
5.5. Defined Status Variables:
maxVolume minVolume speakerCommunicationStable identificationActive profileList
Genelec Smart IP driver for LARA

networkData measurementData audioInputData danteIPData danteIdentity versionString muteState volumeValue powerstate

Page 6

Content of these status variables based on the Genelec Smart IP API interface's description. Please refer to this API manual, and find some examples in the next chapter.

Genelec Smart IP driver for LARA

Page 7
6. Defined Methods
6.1. put, post, get, del
Common rest api methods
6.2. heartbeat
Periodically queries data for the dashboard of LARA from the loudspeaker.
6.3. setMute
Sets the Mute State of the loudspeaker. It the parameter is "true" the speaker is muted, in case of "false" the spekaer is unmuted.
6.4. setVolume
Sets the loudspeaker's volume level via the "level" Parameter, wich can be within this range: -133 .. 0 dB
6.5. setPowerSate
Sets the Power State of the loudspeaker. It the parameter is "ACTIVE" the device is powered on, in case of "STANDBY" the device is on standby mode.
6.6. getDeviceInfo
Gets the following device information: Versionstring: {
fwId: '44x0-1.4.0-202405311152', build: '7f915d', baseId: '1.0.0', hwId: '', model: '4420', category: 'SAM_2WAY', technology: 'SAM_IP', upgradeId: 10, apiVer: 'v1' }
6.7. getAoIPIdent
Gets the AV over IP ( Dante ) information: Dante information: {
id: '001dc1fffe829b26', name: 'Genelec-829b26', fname: 'Genelec-829b26', mac: '00:1D:C1:82:9B:26' }
6.8. getAoIPData
Gets the AV over IP ( Dante ) network parameters: Dante information: { ip: '192.168.5.70', mask: '255.255.252.0', gw: '192.168.7.254' }
Genelec Smart IP driver for LARA

6.9. getMeasurementData
Gets the measured parameters from the loudspeaker.
[2024-06-25 14:12:23.399] - TEST_logic - Measurement data: { uptime: '23h 44m 6s', bsLevel: -197.900009, twCoilT: 53, twLevel: -185.5, inLevel: -116.800003, nwInKbps: 76, cpuLoad: 69, cpuT: 53.6000023
}

6.10.

getProfileList
Gets list of profiles stored in the loudspeaker Profile list: { selected: 0, startup: 0, list: [] }

6.11. setProfileID
Restore profile from flash and set it as an active profile.

6.12.

getNetworkConfig
Gets the network configuration.
Network data: { hostname: '4420-200502', mode: 'auto', ip: '192.168.5.68', mask: '255.255.252.0', gw: '192.168.7.254', volIp: '0.0.0.0', volPort: 0, auth: 'admin:admin'
}

6.13.

getAudioInputData
Gets the list of selected inputs. Audio input information: { input: [ 'A', 'AoIP01', 'AoIP02' ] }

6.14. identification
Identify the speaker by flashing front LED
6.15. setLEDIntensity
Sets the speaker's front LED brightness

Genelec Smart IP driver for LARA

Page 8

7. Defined Rules in the Test Logic Module
There are two kinds of Rules defined in the TEST logic module. To test the system please find the QR code link button in the Control Panel section:

Page 9

After pushing it the new browser window will open with a simple menu bar. In this menu bar Speaker Control submenu opens the operational panel:

7.1. Rules for setting parameters of the loudspeaker: setVolume, Power On, Standby, speaker Mute pressed, profile button pressed These Rules are triggered by events emitted by the Control panel ( button press, slider move )
Genelec Smart IP driver for LARA

Page 10
7.2. Rules for getting data from the loudspeaker Rules are triggered by changes of the corresponding Status Variables of Speaker Module e.g. gives feedback for changing the volume value for the speaker. Genelec Smart IP driver for LARA

Page 11
The actions made in these Rules are very simple just they log out the content of the given Status Variable if the logging is enabled in the parameter section.

Rev. v1.0.0 v1.1.0

Release date 02-07-2028 22-08-2024

Changes
Initial version
setLedIntensity, min/max Volume, UCX-BD series built DSP control added

Editor Péter Szabó 3 Péter Szabó 3

Genelec Smart IP driver for LARA

