Instruction Manual for LIGHTWARE models including: Smart IP Driver, IP Driver, Driver
Lightware Advanced Room Automation (LARA)
File Info : application/pdf, 11 Pages, 735.61KB
DocumentDocumentGenelec Smart IP driver for LARA Page 2 TABLE OF CONTENTS 1. INTRODUCTION ..................................................................................................................................................... 3 2. INSTALLATION AND CONFIGURATION ................................................................................................................... 3 2.1. INSTALLATION ........................................................................................................................................................... 3 2.2. CONFIGURATION........................................................................................................................................................ 4 2.2.1. Starting LARA, Uploading Configuration ...................................................................................................... 4 3. DASHBOARD CONTENT.......................................................................................................................................... 4 4. DEFINED PARAMETERS .......................................................................................................................................... 4 5. DEFINED EVENTS ................................................................................................................................................... 5 5.1. HEARTBEAT_PRIOD: ................................................................................................................................................... 5 5.2. SPEAKERERROR: ........................................................................................................................................................ 5 5.3. ERROR: .................................................................................................................................................................... 5 5.4. RESPONSERECEIVED: .................................................................................................................................................. 5 5.5. DEFINED STATUS VARIABLES: ....................................................................................................................................... 5 6. DEFINED METHODS ............................................................................................................................................... 7 6.1. PUT, POST, GET, DEL ................................................................................................................................................... 7 6.2. HEARTBEAT ............................................................................................................................................................... 7 6.3. SETMUTE ................................................................................................................................................................. 7 6.4. SETVOLUME.............................................................................................................................................................. 7 6.5. SETPOWERSATE......................................................................................................................................................... 7 6.6. GETDEVICEINFO......................................................................................................................................................... 7 6.7. GETAOIPIDENT ......................................................................................................................................................... 7 6.8. GETAOIPDATA .......................................................................................................................................................... 7 6.9. GETMEASUREMENTDATA ............................................................................................................................................ 8 6.10. GETPROFILELIST ................................................................................................................................................... 8 6.11. SETPROFILEID...................................................................................................................................................... 8 6.12. GETNETWORKCONFIG ........................................................................................................................................... 8 6.13. GETAUDIOINPUTDATA .......................................................................................................................................... 8 6.14. IDENTIFICATION.................................................................................................................................................... 8 6.15. SETLEDINTENSITY ................................................................................................................................................ 8 7. DEFINED RULES IN THE TEST LOGIC MODULE ........................................................................................................ 9 7.1. RULES FOR SETTING PARAMETERS OF THE LOUDSPEAKER:................................................................................ 9 7.2. RULES FOR GETTING DATA FROM THE LOUDSPEAKER ....................................................................................... 10 Genelec Smart IP driver for LARA Page 3 1. Introduction Smart IP LARA module is for controlling Genelec Smart IP loudspeakers using REST style communication with a reduced set of HTTP/1.1 protocol. Smart IP API documentation can be downloadad from here: https://www.genelec.com/smart-ip-api 2. Installation and Configuration 2.1. Installation Minimum equipment requirement for the solution: Lightware UCX series Universal Matrix Switcher (FW: v2.12.0b3) or UCX-BD series Universal Matrix Switcher (FW: v2.14.0b3) with built DSP Smart IP device, in this example: Genelec 4410 loudspeaker (FW: 44x0-1.4.0) Ethernet network switch Cables Before you start, please setup Genelec active speaker as an audio device using Smart IP Manager. Further information can be found here: https://www.genelec.com/smart-ip-manager Before uploading any LARA module, or configuration, please download the latest Firmware from https://lightware.com/. Upgrade your UCX series Universal Matrix Switcher and activate LARA. For further information please refer to the user manuals: https://lightware.com/pub/media/lightware/filedownloader/file/UserManual/Taurus_UCX_series_Users_Manual.pdf https://lightware.com/lara/ https://lightware.com/pub/media/lightware/filedownloader/file/User-Manual/LARA_Users_Manual.pdf Genelec Smart IP driver for LARA Page 4 2.2. Configuration 2.2.1. Starting LARA, Uploading Configuration Start a new browser window typing : https://192.168.1.88/lara where the IP address is : UCX series matrix device Choose: UPLOAD CONFIGURATION For detailed information please find chapter 5.7. Lightware Advanced Room Automation (LARA) in this document: https://lightware.com/pub/media/lightware/filedownloader/file/UserManual/Taurus_UCX_series_Users_Manual.pdf 3. Dashboard Content The following status indicator is displayed on the Status board in the row of the instance: Connection state of the device Product data ( Device type, FW version ) Power status, Mute status, Volume level, Zone information, Device information 4. Defined parameters ipAddressOrHost: The IP address or the host name of the Genelec Smart IP device, hereinafter loudspeaker in this example Username: defined in Smart IP Manager Password: defined in Smart IP Manager Min / Max Volume level can be defined. These are converted to status variables for future use in the logic module. Log messages can be enabled in the log section of LARA GUI. Genelec Smart IP driver for LARA Page 5 5. Defined Events 5.1. Heartbeat_priod: This event is dispatched, after every 5000 ms. This means that the dashboard information is refreshed in every five seconds. 5.2. Speakererror: This event is emitted in case of connection loss between the UCX and the Genelec speaker. 5.3. error: e.g. Problem in the data transmission, e.g. wrongly set frame delimiter. `errormessage` parameter is defined in this event for the error code. 5.4. responseReceived: The received string; `string` parameter is defined in this event. It can be used to analyse the content of the response received from the device. 5.5. Defined Status Variables: maxVolume minVolume speakerCommunicationStable identificationActive profileList Genelec Smart IP driver for LARA networkData measurementData audioInputData danteIPData danteIdentity versionString muteState volumeValue powerstate Page 6 Content of these status variables based on the Genelec Smart IP API interface's description. Please refer to this API manual, and find some examples in the next chapter. Genelec Smart IP driver for LARA Page 7 6. Defined Methods 6.1. put, post, get, del Common rest api methods 6.2. heartbeat Periodically queries data for the dashboard of LARA from the loudspeaker. 6.3. setMute Sets the Mute State of the loudspeaker. It the parameter is "true" the speaker is muted, in case of "false" the spekaer is unmuted. 6.4. setVolume Sets the loudspeaker's volume level via the "level" Parameter, wich can be within this range: -133 .. 0 dB 6.5. setPowerSate Sets the Power State of the loudspeaker. It the parameter is "ACTIVE" the device is powered on, in case of "STANDBY" the device is on standby mode. 6.6. getDeviceInfo Gets the following device information: Versionstring: { fwId: '44x0-1.4.0-202405311152', build: '7f915d', baseId: '1.0.0', hwId: '', model: '4420', category: 'SAM_2WAY', technology: 'SAM_IP', upgradeId: 10, apiVer: 'v1' } 6.7. getAoIPIdent Gets the AV over IP ( Dante ) information: Dante information: { id: '001dc1fffe829b26', name: 'Genelec-829b26', fname: 'Genelec-829b26', mac: '00:1D:C1:82:9B:26' } 6.8. getAoIPData Gets the AV over IP ( Dante ) network parameters: Dante information: { ip: '192.168.5.70', mask: '255.255.252.0', gw: '192.168.7.254' } Genelec Smart IP driver for LARA 6.9. getMeasurementData Gets the measured parameters from the loudspeaker. [2024-06-25 14:12:23.399] - TEST_logic - Measurement data: { uptime: '23h 44m 6s', bsLevel: -197.900009, twCoilT: 53, twLevel: -185.5, inLevel: -116.800003, nwInKbps: 76, cpuLoad: 69, cpuT: 53.6000023 } 6.10. getProfileList Gets list of profiles stored in the loudspeaker Profile list: { selected: 0, startup: 0, list: [] } 6.11. setProfileID Restore profile from flash and set it as an active profile. 6.12. getNetworkConfig Gets the network configuration. Network data: { hostname: '4420-200502', mode: 'auto', ip: '192.168.5.68', mask: '255.255.252.0', gw: '192.168.7.254', volIp: '0.0.0.0', volPort: 0, auth: 'admin:admin' } 6.13. getAudioInputData Gets the list of selected inputs. Audio input information: { input: [ 'A', 'AoIP01', 'AoIP02' ] } 6.14. identification Identify the speaker by flashing front LED 6.15. setLEDIntensity Sets the speaker's front LED brightness Genelec Smart IP driver for LARA Page 8 7. Defined Rules in the Test Logic Module There are two kinds of Rules defined in the TEST logic module. To test the system please find the QR code link button in the Control Panel section: Page 9 After pushing it the new browser window will open with a simple menu bar. In this menu bar Speaker Control submenu opens the operational panel: 7.1. Rules for setting parameters of the loudspeaker: setVolume, Power On, Standby, speaker Mute pressed, profile button pressed These Rules are triggered by events emitted by the Control panel ( button press, slider move ) Genelec Smart IP driver for LARA Page 10 7.2. Rules for getting data from the loudspeaker Rules are triggered by changes of the corresponding Status Variables of Speaker Module e.g. gives feedback for changing the volume value for the speaker. Genelec Smart IP driver for LARA Page 11 The actions made in these Rules are very simple just they log out the content of the given Status Variable if the logging is enabled in the parameter section. Rev. v1.0.0 v1.1.0 Release date 02-07-2028 22-08-2024 Changes Initial version setLedIntensity, min/max Volume, UCX-BD series built DSP control added Editor Péter Szabó 3 Péter Szabó 3 Genelec Smart IP driver for LARA