Instruction Manual for Skinner models including: BCTB Stainless Steel Band Clamp, BCTB, Stainless Steel Band Clamp, Steel Band Clamp, Band Clamp, Clamp, BCTB Stainless Steel Band Clamp

The Skinner Company

Skinner

Skinner Company Skinner Seal BCEC BCFC BCSB BCDB BCTB Stainless Steel Band Clamp IOM I&M Manual - BriceBarclay

Manual - Skinner Company, Skinner Seal, Model BCEC, BCFC, BCSB, BCDB, BCTB, Stainless Steel Band Clamp IOM, I&M

The Skinner Company Stainless Steel Full Circle Wrap Band Repair Clamp (Model BCFC) - BriceBarclay


File Info : application/pdf, 1 Pages, 58.12KB

PDF preview unavailable. Download the PDF instead.

Skinner Company Skinner Seal BCEC BCFC BCSB BCDB BCTB Stainless Steel Band Clamp IOM IM Manual
The Skinner Company
1519 Evans Pond Road Greenwood, South Carolina 29649
USA
877-923-7700 (Ph) 864-953-9724 (Fx) www.skinnerco.com
INSTALLATION PROCEDURE

BAND CLAMPS:
The Skinner Band Clamps are designed for use on Steel, Ductile and Cast Iron pipes to repair pit holes, splits, and corrosion leaks. This clamp can be used on pipes for Gas, Water, Oil, or Ammonia. Sizes and pressure ratings are as follows:

Model
BC-EC BC-EC BC-FC BC-FC BC-SB
BC-SB
BC-DB
BC-DB

Sizes
0.75" ­ 1.50" 2.00" ­ 8.00" 0.75" ­ 1.50" 2.00" 2.00" ­ 12.00"
2.00" ­ 12.00"
4.00"­ 8.00"
10.00"­12.00"

Widths
3" & 6" 3" & 6" 3" & 6" 3" & 6" 7.5" & 12.5" 7.5" & 12.5" 7.5" & 12.5" 10" & 12.5"

Bolt Torque
25 ft/lb 35 ft/lb 25 ft/lb 35 ft/lb 55 ft/lb on ½" bolts 95 ft/lb on 3/4" bolts 55 ft/lb on ½" bolts 95 ft/lb on 3/4" bolts

Max Working Pressure 100 psi 100 psi 100 psi 100 psi 150 psi
150 psi
300 psi
300 psi

Applications
Small pin hole leaks Small pin hole leaks Full circle gasket Full circle gasket All Stainless, single band.
All Stainless, single band.
All Stainless, double band.
All Stainless, double band.

Installation Procedure:

Step #1
Step #2
Step #3
Step #4 Step #5 Step #6 Step #7

Thoroughly clean the damaged area with a wire brush. Remove all pipe scale, rust, and foreign material. This will help insure a "bubble tight" seal. Back off the ends of the bolts, but do not remove them. Separate halves and fit around pipe. Center the gasket over the area of the leak. Make sure the gasket extends past the damaged area. Relocate the bolt heads securely into their receiving lugs. Tighten the bolts evenly to the recommended torque shown above. Pressure test the complete installation for leaks. Check for leaks before leaving repair site.

GASKET Material: Buna-N (Nitrile Rubber) rated at 250 F Max to -20 F Min Temp.