Instruction Manual for Pepperl Fuchs models including: FB4202B2 HART Output Isolator, FB4202B2, HART Output Isolator, Output Isolator, Isolator
Part Number | HART Output Isolator | Pepperl Fuchs | MISUMI
Pepperl Fuchs-HART Output Isolator-FB4202B2-27 V, 87 mA, 575 mW - 220087 | ISC Sales
File Info : application/pdf, 3 Pages, 508.05KB
DocumentDocumentHART Output Isolator FB4202B2 < 1-channel < Output Ex ia < Installation in suitable enclosures in Zone 1 < Module can be exchanged under voltage (hot swap) < Analog output module for 0/4 mA ... 20 mA < HART communication via field bus or service bus < Simulation mode for service operations (forcing) < Line fault detection (LFD) < Permanently self-monitoring Release date: 2021-11-16 Date of issue: 2021-11-16 Filename: 220087_eng.pdf P I HART COM Function The device drives positioners, proportional valves, I/P converters, or local indicators. Open and short-circuit line faults are detected. The output is galvanically isolated from the bus and the power supply. Connection 6 543+ 2+ 1 I Zone 0, 20 Technical Data Slots Occupied slots Supply Connection Rated voltage Power dissipation Power consumption Internal bus Connection Interface Analog output Number of channels Zone 1 1 backplane bus Ur 12 V DC , only in connection with the power supplies FB92** 0.8 W 0.95 W backplane bus manufacturer-specific bus to standard com unit 1 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com USA: +1 330 486 0002 pa-info@us.pepperl-fuchs.com Germany: +49 621 776 2222 pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 1 HART Output Isolator Technical Data FB4202B2 Suitable field devices Field device Proportional Valve Field device [2] I/P converters Field device [3] on-site display Connection channel I: 2/3+, 4/5- Current 0 ... 25 mA short-circuit protected Line fault detection can be switched on/off for each channel via configuration tool , configurable via configuration tool Short-circuit No Open-circuit deviation of preset output value > 0.5 mA Load 750 max. HART communication yes HART secondary variable MODBUS: yes; all other bus systems: no Watchdog within 0.5 s the device goes in safe state, e.g. after loss of communication Transfer characteristics Deviation After calibration 0.1 % of the signal range at 20 °C (68 °F) Influence of ambient temperature 0.1 %/10 K of the signal range Refresh time 100 ms Indicators/settings LED indication Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1) red: line fault (lead breakage or short circuit) Coding optional mechanical coding via front socket Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Conformity Electromagnetic compatibility NE 21:2007 Degree of protection IEC 60529:2000 Environmental test EN 60068-2-14:2009 Shock resistance EN 60068-2-27:2009 Vibration resistance EN 60068-2-6:2008 Damaging gas EN 60068-2-42:2003 Relative humidity EN 60068-2-78:2001 Ambient conditions Ambient temperature -20 ... 60 °C (-4 ... 140 °F) Storage temperature -25 ... 85 °C (-13 ... 185 °F) Relative humidity 95 % non-condensing Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 (module) , a separate housing is required acc. to the system description Connection removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) Mass approx. 350 g Dimensions 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch) Data for application in connection with hazardous areas EU-type examination certificate BVS 12 ATEX E 015 X Release date: 2021-11-16 Date of issue: 2021-11-16 Filename: 220087_eng.pdf Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com USA: +1 330 486 0002 pa-info@us.pepperl-fuchs.com Germany: +49 621 776 2222 pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 2 HART Output Isolator Technical Data Marking Output Voltage Current Power Galvanic isolation Output/power supply, internal bus Directive conformity Directive 2014/34/EU International approvals ATEX approval General information System information Supplementary information Assembly Front view FB4202B2 1 II 2(1) G Ex d [ia Ga] IIC T4 Gb 1 II (1) D [Ex ia Da] IIIC Uo 27 V Io 87 mA Po 575 mW (linear characteristic) safe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-11:2012 BVS 12 ATEX E 015 X The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Power LED green Status LED red Diagnostic LED red/white Space for labelling 6 5 4 3 Socket for 2 removable plug 1 blue (accessory) Release date: 2021-11-16 Date of issue: 2021-11-16 Filename: 220087_eng.pdf Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com USA: +1 330 486 0002 pa-info@us.pepperl-fuchs.com Germany: +49 621 776 2222 pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 3