Midea Dehumidifier User Manual

Model: US-OSK103

Power Source: 115V, 60Hz

Table of Contents

Safety Precautions

Before Operation and Installation:

To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage.

WARNING: This symbol indicates the possibility of personnel injury or loss of life.

CAUTION: This symbol indicates the possibility of property damage or serious consequences.

General Warnings:

Additional Precautions:

Preparation

Identification of Parts

NOTE: All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail. The unit can be controlled by the unit control panel.

Parts: Air outlet grille, Control panel, Handle, Quick glance light (some units), Water bucket, Casters (some units), Air intake grille, Air filter (behind the grille).

Installation Instructions

  1. Take out the dehumidifier from the package.
  2. Hold the handle and lift the dehumidifier up, pull out the power cord, and rotate 90° counterclockwise.
  3. Place the dehumidifier into the water bucket gently according to the ALIGN label until it clicks in place. Do never install it rudely.

NOTE: During the operation, it is normal if you press the top cover and the dehumidifier shakes slightly.

Storage Instructions

  1. Press in the convex piece in the water bucket.
  2. Lift the dehumidifier body handle, rotate 90° clockwise.
  3. Install the power cord into the in-line slot, put the dehumidifier into the package to store.

Caster installation and disassembly instructions (some units)

Installation:

  1. Attach the caster to the bottom of the unit.
  2. Use a block to fix it as shown in the picture.

Disassembly:

  1. To remove the caster, use a screwdriver to prop up the block, then take it down.
  2. Then remove the caster.

Design Notice

In order to ensure the optimal performance of our products, the design specifications of the unit are subject to change without prior notice.

Positioning the unit

Clearances: 40cm or more on sides, 20cm or more on front and back, 40cm or more above the air outlet.

Casters (At four points on the bottom of unit):

When using the unit

NOTE: When the water in the bucket reaches a certain level, please be careful to move the machine to avoid it falling down.

Operating Instructions

Control Panel Features

NOTE: The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly different according to the models. Your machine may not contain some indicators or buttons. The actual shape shall prevail.

Indicator Lights and Functions:

Indicator Function Indicator Function
Wireless light Wireless light Filter clean light Filter clean light
Bucketless Mode Bucketless Mode Pump light (for pump model only) Pump light (for pump model only)

When you push the button to change operation modes, the unit will make a beep sound to indicate that it is changing modes.

Buttons and Functions:

Display

Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the actual (±5% accuracy) room % humidity level in a range of 30% RH (Relative Humidity) to 90% RH (Relative Humidity).

Error Codes:

Protection Codes:

NOTE: When one of the above malfunctions occurs, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact the manufacturer or its service agents or a similar qualified person for service.

Other features

Note:

  1. The Dryer/MAX (model dependent) mode must be operated in a closed room; do not open the door and window.
  2. To make the best effective dehumidification, please first dehydrate the wet clothes.
  3. Make sure to direct airflow at the wet clothes.
  4. For thick and heavy wet clothes, the dehumidification may not be the best effective.

Bucketless mode (on some models): The dehumidifier can be used without a bucket when in bucketless mode. The unit will not remind you when the water is full, therefore, it is suggested that:

  1. Check if the tube is properly connected.
  2. Link the other end of the tube to a place with unlimited capacity, such as a sink or a basin.
  3. Do not place the other end of the tube in a container with limited capacity, otherwise the water may overflow to the floor.

Exit the bucketless mode:

  1. Press FILL LEVEL and UP to exit.
  2. Turn off the power.

NOTE: It may cause an unexpected exit from the bucketless mode when the tank float touches the micro switch (at the bottom of the unit). So please check whether the bottom of the unit is clear under the bucketless mode.

Note:

  1. Please make sure the unit is placed on a flat, horizontal table to prevent toppling and sliding. The tilt angle needs to be less than 1 degree.
  2. Please make sure the tube is properly connected to the drain before entering the bucketless mode.
  3. The overall height of the tube should be lower than the drain to avoid water backflow and ensure smooth discharge.

NOTE: At the Bucketless mode, the height of the table must be more than 10cm.

Place the end of the hose into the drain area or the container to catch the water.

Continuous draining: Water can be automatically emptied into a floor drain by attaching the unit with a water hose (not included). Remove the cover located on the back of the water bucket, then remove the rubber plug. Attach a drain hose and lead it to the floor drain or a suitable drainage facility.

Make sure the hose is secure so there are no leaks. Direct the hose toward the drain area, making sure that there are no kinks that will stop the water flowing. Place the end of the hose into the drain area and make sure the end of the hose is level or downwards to let the water flow smoothly. Do never let it up. Make sure the hose is lower than the drain hose outlet. Select the desired humidity setting and fan speed on the unit for continuous draining to start. Note: When the continuous drain feature is not being used, remove the drain hose from the outlet, reinstall the rubber plug and cover.

Pump draining (on some models): Water can be automatically emptied into a floor drain or a suitable drainage facility by attaching the pump drain outlet with a pump drain hose (Φod=1/4", supplied).

Install the pump hose into the pump hose intake of the unit, and rotate it. Install the pump drain hose into the pump drain hose outlet for depth of 15mm at least, then lead the water hose to the floor drain or a suitable drainage facility. Put the dehumidifier on the bucket again. Press and hold the Up/Down buttons for 2 seconds to initiate PUMP feature. When the PUMP is activated, the bucket capacity is at the 4th fill level and cannot be selected. The PUMP works only if the bucket is full of water at the 4th fill level. Select the desired humidity setting and fan speed on the unit for pump draining to start.

Note: The pump operation light blinks at 1Hz when the pump is operational failure. Please turn off the unit and plug the power cord out. Check the following:

Note: Do not use this operation when the outdoor temperature is equal to or less than 0 °C (32°F), otherwise water will become ice that will cause the water hose to be blocked up and the unit to fail. Make sure to empty the bucket once a week when using the pump draining feature. When the pump draining feature is not being used, remove the pump drain hose from the outlet.

Press the pump drain hose outlet in and take the pump drain hose out from it. Take the pump hose out from the unit. Make sure do not let the water in the pump hose drip to the floor.

Note: The pump may cause loud noise when it starts to work for 3~5 minutes. It is a normal phenomenon.

Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing. Place the end of the hose into the drain and make sure the end of the hose is level or down to let the water flow smoothly. Do never let it up.

Care and Maintenance

Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.

Clean the Grille and Case

Clean the bucket

Every few weeks, clean the bucket to prevent the growth of mold, mildew, and bacteria. Partially fill the bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty and rinse.

Note: Do not use a dishwasher to clean the bucket. After cleaning, the bucket must be in place and securely seated for the dehumidifier to operate.

Clean the air filter

The air filter behind the two flanks grille should be checked and cleaned at least every two weeks or more often if necessary.

NOTE: DO NOT RINSE OR PUT THE FILTER IN AN AUTOMATIC DISHWASHER.

To remove: Grip the handle on the filter and pull it outward.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

To attach: Insert the air filter back into the unit.

CAUTION: DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance.

Note: The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleansers, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the unit.

Troubleshooting Tips

Before calling for service, review the chart below first yourself.

Problem What to check
Unit does not start
  • Make sure the dehumidifier's plug is pushed completely into the outlet.
  • Check the house fuse/circuit breaker box.
  • Dehumidifier has reached its preset level or bucket is full.
  • Water bucket is not in the proper position.
Dehumidifier does not dry the air as it should
  • Did not allow enough time to remove the moisture.
  • Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier.
  • The humidity control may not be set low enough.
  • Check that all doors, windows and other openings are securely closed.
  • Room temperature is too low, below 5 °C (41° F).
  • There is a kerosene heater or something giving off water vapor in the room.
The unit makes a loud noise when operating
  • The air filter is clogged.
  • The unit is tilted instead of upright as it should be.
  • The floor surface is not level.
Frost appears on the coils. This is normal. The dehumidifier has Auto defrost feature.
Water on floor
  • Hose to connector or hose connection may be loose.
  • Intend to use the bucket to collect water, but the back drain plug is removed.
EH60, EH61, EH0b, Eb or P2 appear in the display These are error codes and protection codes. See the CONTROL PADS ON THE DEHUMIDIFIER section.

When not using the unit for long time periods:

App Instructions

Declaration of Conformity

We hereby declare that this Dehumidifier is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

Specification of Wireless Module

Model US-OSK103 Dimensions 41 x 24 x 5 (mm)
Standard IEEE 802.11 b/g/n Operation Temperature 0°C ~ 45°C / 32°F ~ 113°F
Antenna Type External omnidirectional Antenna Operation Humidity 10% ~ 85%
Frequency 2.4 GHz (wireless) Power Input DC 5V/300 mA
Maximum Transmitted Power 19.8 dBm Max

Precautions

  1. Supports operating systems: iOS 7+ or Android 4+.
  2. In the event of an OS update, there may be a delay between the update of the OS and a related software update during which your OS may or may not be supported until a new version is released. Your specific mobile phone or problems in your network may prevent the system from working and Midea will not be responsible for any problems that could be caused by incompatibility or network issues.
  3. This Smart Dehumidifier only supports WPA-PSK/WPA2-PSK (recommended) encryption.
  4. To ensure proper scanning of the QR code, your smartphone must have at least a 5-megapixel camera.
  5. Due to unstable network connectivity, requests may time out. If this happens, re-run the network configuration.
  6. Due to unstable network connectivity, commands may time out. If this happens, the smartphone app and the actual product may display conflicting information. The information displayed on the actual product is always the most accurate available. Refresh the app to re-sync.

NOTICE

Midea will not be responsible for any problems that could be caused by incompatibility or network issues, your wireless router and mobile phone.

System Overview

Devices required to use the Smart Dehumidifier:

  1. Smart Phone with compatible iOS or Android system.
  2. Wireless Router
  3. Smart Dehumidifier

Download and Install the App

Scan to download app.

You can also go to Google Play or App Store and search for Midea Air.

NOTICE

All the images in this manual are for reference only, your product and app may look slightly different. The actual product and app instructions have to be considered.

Create Your Account

1. Press "Sign Up”.

2. Enter your email address and password.

3. Press “Registration”.

4. If you forget your password, press “Forgot password?” on the main menu and enter your email address. Then press “Reset Password”.

NOTICE

Additional App and Smart Home Functions: For additional instructions regarding the features of the app and Smart Home skill capabilities, scan the QR code below.

WARRANTY

These products have been made to quality standards and are guaranteed for domestic use against manufacturing faults.

One (1) year full warranty from original purchase date and limited 2nd through 5th year sealed system warranty if used for normal domestic purposes.

This warranty does not affect your statutory rights. In case of any malfunction of your product (failure, missing part, etc.), please contact one of our service technicians at our toll-free service line at 1-866-646-4332 from 8 AM to 6 PM EST, Monday to Friday, and 8 AM to 4 PM EST, Saturday. Midea reserves the right to repair or replace the defective product, at its discretion.

Any warranty is invalid if the product has been overloaded or subject to neglect, improper use or an attempted repair other than by an authorized agent. Heavy-duty or daily professional/commercial usage are not guaranteed. Due to continuous product improvement, we reserve the right to change product specifications without prior notice.

For instructions on how to properly drain Freon, please contact our customer service at 1-866-646-4332. Thank you.

Models: US-OSK103 CUBE Dehumidifier, US-OSK103, CUBE Dehumidifier, Dehumidifier

File Info : application/pdf, 40 Pages, 41.45MB

PDF preview unavailable. Download the PDF instead.

CUBE-dehumidifier-manual Acrobat Distiller 9.0.0 (Windows)

Related Documents

Preview Midea Cube Dehumidifier MAD User Manual
User manual for the Midea Cube Dehumidifier, model series MAD. This guide provides instructions on setup, operation, care, and troubleshooting for Midea dehumidifiers.
Preview Midea Dehumidifier User Manual: CDDOE-10DEN7-QA3 & CDDOE-12DEN7-QA3
Comprehensive user manual for Midea dehumidifiers, models CDDOE-10DEN7-QA3 (EU) and CDDOE-12DEN7-QA3 (EU). Includes safety precautions, operating instructions, maintenance, troubleshooting, and specifications.
Preview Midea Dehumidifier MDP Series User Manual
Comprehensive user manual for the Midea MDP series dehumidifiers, including models MDP30SR71, MDP50SR71, MDP70SR71, and MDP70PR71. Covers safety precautions, unit specifications, operating instructions, installation, care and cleaning, and troubleshooting.
Preview Midea MMP-20GC3D Microwave Oven User Manual
Comprehensive user manual for the Midea MMP-20GC3D Mirror Plus microwave oven, covering safety instructions, operating procedures, automatic menus, troubleshooting, and specifications.
Preview Midea MAD Dehumidifier User Manual
Comprehensive user manual for the Midea MAD series dehumidifier, covering setup, operation, maintenance, troubleshooting, and app integration.
Preview Midea Dehumidifier User Manual: MAD22C1AWS, MAD35C1AWS, MAD50C1AWS, MAD50P1AWS
Comprehensive user manual for Midea dehumidifiers (models MAD22C1AWS, MAD35C1AWS, MAD50C1AWS, MAD50P1AWS), covering safety precautions, specifications, operating instructions, app control, cleaning, maintenance, and troubleshooting.
Preview Midea Dehumidifier MAD User Manual
Comprehensive user manual for the Midea Dehumidifier MAD series, covering safety precautions, unit specifications, installation, operation, app control, troubleshooting, and warranty information.
Preview Midea Dishwasher MDWPS1401KSS User Manual
Comprehensive user manual for the Midea Dishwasher, model MDWPS1401KSS, providing detailed instructions on operation, safety, features, maintenance, and troubleshooting.