Owner's Manual for Senseair models including: tSENSE CO2 Temperature and RH Sensor with Colour Touch Display, tSENSE, CO2 Temperature and RH Sensor with Colour Touch Display, Colour Touch Display, CO2 Temperature and RH Sensor, RH Sensor, Sensor

Download hier de technische fiche

SenseAir tSense Disp | EURO-INDEX

tSENSE (Disp) - EURO-INDEX

Wijzigingen voorbehouden EURO-INDEX VL 18001 Het Bluetooth woord- en beeldmerk zijn eigendom van Bluetooth SIG, Inc. Gebruik van deze merken door EURO-INDEX geschiedt onder licentie. Service van EURO-INDEX EURO-INDEX verleent service op alle meetinstrumenten uit haar leveringspakket en biedt de faciliteiten, kennis en


File Info : application/pdf, 3 Pages, 794.39KB

PDF preview unavailable. Download the PDF instead.

senseair-tsense-disp-ds-en-vl
tSENSE (Disp)

CO2, Temperature and RH Sensor with colour touch display
tSENSE is an advanced and versatile 3-in-1 sensor designed for installation in the air-conditioned zone. It measures CO2 concentration, temperature and humidity in the ambient air accurately without need for additional compensation ­ true read. The data transmits to a BMS system or stand-alone controller using industry standard output signals and communication protocols.
tSENSE combines all the necessary elements for effective climate control in commercial office buildings, hospitals, hotels, schools and other facilities. Using CO2monitoring for demand control ventilation (DCV) allows healthy, comfortable and cost-effective environment for the occupants. tSENSE is flexible in design with temperature control in combination with humidity control optional. Though suitable for use in many different energyefficient ventilation strategies, Senseair welcomes any discussions for specific needs.
Complies with ASHRAE standard 189.1 (±50ppm @ 1000ppm of measured CO2 value)

Standard specification
Measured gas Operating principle
Measurement range OUT1 CO2 OUT2 Temperature OUT3 Relative Humidity Relay CO2
Accuracy (CO2) Dimensions [mm] Dimensions display [mm] Life expectancy Operation temperature range Power supply Communication

Carbon dioxide (CO2) Non-dispersive infrared (NDIR) 0­2000ppm 0­10VDC, 0­2000ppm 0­10VDC, 0­50°C 0­10VDC, 0­100%RH On 1000 ppmvol Off 900ppmvol ±30 ppm ±3% of reading 125 x 85 x 22 49 x 37 >15 years 0­50°C 12VDC, 24VAC/DC Modbus (MB) or BACnet (BAC) protocol over RS485

Key benefits
· Maintenance free · Three sensors in one housing: CO2, temp and RH · Colour touch display with possibility of customisable GUI · PIN codes for access to display and meter settings · Improved housing design for effective measurement

Document: PSH0109

Rev: 18

©2019 Senseair AB. All rights reserved.
Page 1/2

An Asahi Kasei Group Company.

tSENSE (Disp) Technical Specification

General Performance:
Storage Temperature Range Sensor Life Expectancy Maintenance Interval 1 Self-Diagnostics Display (Disp) Buttons Warm-up Time Operating Temperature Range Operating Humidity Range Operating Environment

-30­70°C >15 years Maintenance free Complete function-check of the sensor module Configurable colour LCD with CO2 [ppm], Temperature [°C] and Humidity [%RH] Touch display (Disp) 1min.(@ full specs 15min ) 0­50°C 0­95%RH, non condensing humidity environment Residential, commercial

Electrical / Mechanical:
Power Input Power Consumption Peak Power Consumption Wiring Connections
CO Measurement: 2 Sensing Method Sampling Method Response Time (T1/e) Measurement Range Accuracy 2
Pressure Dependence Measurement Interval

12VDC, 24VDC or 24VAC (50­60Hz) ±20% <0.35W average non-display version, <0.6W display version <2W Screw terminal, max 1.5mm2, Containing: Power, GND, Out1, Out2, Out3, RS485. Option: passive temperature or relay
Non-dispersive infrared (NDIR) waveguide technology Diffusion <3min 0­2000ppmvol. ±50ppm (@1000ppmvol, 17­28°C and 30­60%RH) Typical full range: ±30ppm +3% of measured value 3, 4 +1.58% reading per kPa deviation from normal pressure, 101.3kPa 15s

Temperature Measurement:
Measurement Range (T) Accuracy 5 Repeatability Response Time Measurement Interval

0­50°C ±0.5°C (@ 17­28°C), ±1.0°C (outside 0­50°C) ±0.25°C (@ 17­28°C) <6min (Air velocity of 0.15m/s) 15s

Relative Humidity Measurement:
Measurement Range Accuracy 5 Hysteresis Annual Drift Repeatability Response Time Measurement Interval

0­100%RH ±5%RH (@ 20­80%RH) ±1%RH (@ 20­80%RH) <±0.5%RH ±0.25%RH (@ 17­28°C) <6min (Air velocity of 0.15m/s) 15s

Outputs:
Linear Analog Outputs:
Protection Output Conversion Accuracy Output Signal Output Resolution Out1: CO2 6 Out2: Temperature (T) 7
Out3: Relative Humidity (RH) 7
Digital Output:
Relay (RL) 6
Input Source

PTC-fuses (auto reset), short-circuit safe ±2% of reading ±20mV Voltage output 0­10V, Rout <100, Load: >5k 10-bits, 10mV steps, 0.1% steps of full ppm/°C/%RH range 0­10V, corresponds to 0­2000 ppmvol, at screw terminal 0­10V, corresponds to 0­50°C, at screw terminal
0­10V, corresponds to 0­100%RH, at screw terminal
On 1000 ppmvol CO2, Off 900ppmvol, CO2, at screw terminal Form C / DPDT, Imax: 1A/50VAC/24VDC CO2 / T / RH (configurable via touch display)

Note 1: Note 2: Note 3:
Note 4: Note 5: Note 6:

No maintenance required in normal indoor air as ABC (Automatic Baseline Correction) is used.
In normal IAQ applications, accuracy is defined after minimum three (3) ABC-pe riods of continuous operation with ABC.
Accuracy is specified over operating temperature range. Specification is refer enced to certified calibration mixtures. Uncertainty of calibration gas mixtures (±1% currently) is to be added to the specified accuracy for absolute measurements.
Repeatability is included. Uncertainty of calibration gases (±1%) is added to the specified accuracy.
Depending on display brightness setting.
Can be configured with PC software UIP (version 5 or later). See information at senseair.com

Document: PSH0109

Rev: 18

©2019 Senseair AB. All rights reserved.
Page 2/2

An Asahi Kasei Group Company.

Service van EURO-INDEX

EURO-INDEX verleent service op alle meetinstrumenten uit haar leveringspakket en biedt de faciliteiten, kennis en hoog gekwalificeerd personeel voor (preventief) onderhoud, reparatie en kalibratie van uw meetinstrumenten.

Geautoriseerd Service Centrum ................................................................. EURO-INDEX is van alle vertegenwoordigde merken een Geautoriseerd Service Centrum.

Dit betekent dat uw instrumenten worden behandeld door goed opgeleid en

kundig personeel, dat beschikt over de juiste gereedschappen en software.

Er worden uitsluitend originele onderdelen gebruikt en de garantie van uw

instrument, evenals de certificering (ATEX, EN50379, etc.) blijven intact.

MEER INFO

Service- en kalibratielaboratorium ................................................................

EURO-INDEX beschikt over een bijzonder modern service- en kalibratie-

laboratorium met RvA accreditatie naar NEN-EN-ISO/IEC 17025. Deze accreditatie

geldt voor verschillende grootheden, zoals gespecificeerd in de scope bij accreditatienummer K105.

MEER INFO

Bekijk de video op ons YouTube kanaal en ontdek alles over KWS

KWS® ............................................................................................................

KWS is een een uniek servicesysteem voor uw meetinstrumenten met periodiek

onderhoud en kalibratie. Veel zaken worden voor u geregeld, zodat u zonder

zorgen gebruik kunt maken van uw meetinstrumenten. De kosten zijn laag en voorspelbaar.

MEER INFO

Digitale toegang tot uw kalibratiecertificaten met Mijn KWS .........................

Via het Mijn KWS webportal heeft u altijd en overal toegang

tot uw kalibratiecertificaten en gerelateerde documenten.

MEER INFO

Verhuur van meetinstrumenten ....................................................................

Uitgebreid assortiment

Deskundig advies

Instrumenten worden geleverd met accessoirepakket en herleidbaar kalibratiecertificaat

MEER INFO

EURO-INDEX Academy ....................................................................................

Producttrainingen (individueel en klassikaal)

Seminars

Demonstratie- en instructievideo's

MEER INFO

Servicebalie

Kalibratie rookgasanalyse

Seminars en workshops

Kalibratie thermografie

Wijzigingen voorbehouden EURO-INDEX® VL 18001
Het Bluetooth® woord- en beeldmerk zijn eigendom van Bluetooth SIG, Inc. Gebruik van deze merken door EURO-INDEX geschiedt onder licentie.



References

Adobe InDesign 16.2 (Windows) Adobe PDF Library 15.0