Owner's Manual for Danfoss models including: KDG5V Proportional Two Stage Valve, KDG5V, Proportional Two Stage Valve, Two Stage Valve, Stage Valve, Valve
File Info : application/pdf, 19 Pages, 3.87MB
DocumentDocumentTechnical Catalog Vickers by Danfoss Proportional Two Stage Directional Valves without Electrical Feedback KDG5V-5-*-10 KDG5V-7-*-20 KDG5V-8-*-20 KDG5V-10-*-11 by Danfoss BC451469581724en-000102 Introduction Vickers KDG5V-5/7/8/10 are solenoid operated directional control non-feedback type proportional valves. Two-stage proportional directional control valves in which the main-stage spool is positioned according to the output from an integrally mounted proportional, solenoid-operated , pressure-reducing valve. Direction of main-spool travel depends upon which of the two solenoids of the pilot valve is energized and the amount of travel is dependent upon the current input to the solenoid. At any intermediate position of the main spool, a force balance exists between the controlled, reduced pilot pressure acting on the spool end and the opposing centering spring, plus the action of flow forces. There is no electrical feedback of the main-stage spool position. This range of valves offers effective and economic solutions for applications having repetitive load conditions throughout each operating cycle, e.g. mold closure/opening in plastics molding machinery. Valve sizes 5,7 & 8 are available with integral amplifiers. Features and Benefits D These global products, manufactured to world-class quality standards, are sold and serviced throughout the world. D These valves open up expanded application opportunities as a cost effective alternative to feedback-type proportional and servo valves. D Vickers flexible design approach provides a wide variety of matching electronic amplifiers, valve options, and spool ratings. Typical Section Views KDG5V-7 shown with "EX" or "X" (With integral pilot pressure reducer) KDG5V-7 shown without "EX" or "X" (Without integral pilot pressure reducer) B.2 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.2 Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.2 Typical section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.2 Functional Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.4 Model Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.5 Spool Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.7 Operating Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.8 Performance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.9 Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.13 Mounting Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.16 Electrical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.17 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.18 B.3 Functional Symbols ~x:A:1B1vo XI P T I Y Simplified symbol KDG5V models (Spool type "2" shown) ! -----------1' --------- 7 I b q I I'' '------;-----, I'' i P ,~-7 B AT i L=-- I L I I ___L' __ ----<iL--- P -----~," ---~ B -=-t-_j'_____________7 ~A--:~T ~~-=-----~ : ! I__ J ! i L __ ___________________J_ i X P AB T Y Typical Schematic Symbol-Size 10 * Internal plug shown, for external pilot supply (via port X). For internal pilot supply (from port P) plug is not fitted. Port X should be blocked at mounting interface, or otherwise plugged at subplate or manifold block. See "Model Code". ZInternal plug shown, for external pilot drain (via port Y). For internal pilot drain (via port T) plug is not fitted. Port Y should be blocked at mounting interface, or otherwise plugged at subplate or manifold block. See "Model Code". See also "Pilot Drain Application" notes. PT BA Pilot stage. Solenoids identified "A"/"B" according to "Model Code" designation. * AX P T BA I I I I I I I I ------'s; -- I _ _J 1 I I ---©---~ Z I P T--~Y!__,_B_J Typical Schematic Symbol-Sizes 5/7/8 Pressure reducer module, see "Model Code" Main-stage. Spool type "2C" shown B.4 Model Codes KD G5 V 12 345 -* -********* 6 7 -(**) -(T) -(*) 8 9 10 -(V) -M -******* 11 12 13 -1 -1* 14 15 1 Valve Type Proportional Valve K 2 Control Type D Directional Valve Mounting 3 G Subplate mounted Operation Pilot Operated 4 5 Pressure Rating Pressure rating 350 5 V bar (5000 psi) on P, A & B ports 6 Mounting interface size (ISO 4401) 5 NFPA D05, CETOP 5 7 NFPA D07, CETOP 7 8 NFPA D08, CETOP 8 10 NFPA D10, CETOP 10 7 Spool type, flow rating and metering See "Functional Symbol" on page 6. p = 5 bar (72 psi) per metering flow path, e.g. B to T. Symmetric Spools For KDG5V-5 2C90N 33C80N For KDG5V-7 2C230N 33C230N 36C185N For KDG5V-8 2C330N 33C330N For KDG5V-10 2C550N 12C550N 33C550N 133C550N 90 L/min (24 USgpm) 80 L/min (21 USgpm) 230 L/min (61.3 USgpm) 230 L/min (61.3 USgpm) 185 L/min (48.9 USgpm) 330 L/min (87.2 USgpm) 330 L/min (87.2 USgpm) 550 L/min (145 USgpm) 550 L/min (145 USgpm) 550 L/min (145 USgpm) 550 L/min (145 USgpm) Asymmetric Spools First figure (***N) is flow rating P-A, or A-T ("A" port flow); last figure (N***) is flow rating P-B, or B-T ("B" port flow) For KDG5V-5 2C70N45 33C60N35 For KDG5V-7 2C230N140 33C230N140 For KDG5V-8 33C330N200 133C330N200 2C330N200 For KDG5V-10 2C310N550 2C550N310 33C310N550 33C550N310 133C550N310 733C550N310 70 L/min (18.5 USgpm), "A" port flow 45 L/min (12 USgpm), "B" port flow 60 L/min (15.8 USgpm), "A" port flow 35 L/min (9.2 USgpm), "B" port flow 230L/min (61.3 USgpm), "A" port flow 140L/min (37.3 USgpm), "B" port flow 230L/min (61.3 USgpm), "A" port flow 140L/min (37.3 USgpm), "B" port flow 330 L/min (87.2 USgpm), "A" port flow 200 L/min (52.8 USgpm), "B" port flow 330 L/min (87.2 USgpm), "A" port flow 200 L/min (52.8 USgpm), "B" port flow 330 L/min (87.2 USgpm), "A" port flow 200 L/min (52.8 USgpm), "B" port flow 310 L/min (82 USgpm), "A" port flow 550 L/min (145 USgpm), "B" port flow 550 L/min (145 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow 310 L/min (82 USgpm), "A" port flow 550 L/min (145 USgpm), "B" port flow 550 L/min (145 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow 550 L/min (145.3 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow 550 L/min (145.3 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow B.5 8 Pilot Supply Models without integral, fixed pilot pressure reducer module E External pilot supply Blank Internal pilot supply Models with integral, fixed pilot pressure reducer module X Internal pilot supply EX External pilot supply For system pressures less than 200 bar (2900 psi) the pilot pressure reducing module is optional. For system pressures above 200 bar (2900 psi) the pilot pressure reducing module must be fitted. 9 Pilot drain T Blank Internal pilot drain External pilot drain 10 Manual Override Blank Plain overrides H Water-resistant overrides Z No overrides 11 Solenoid identity V Solenoid "A" at port A end of pilot valve, solenoid "B" at B end. (Energizing "A" gives main-stage flow from port B; energizing "B" gives flow from port A): German practice. Blank Solenoid "A" energized for main-stage flow from port A; solenoid "B" energized for main-stage flow from port B: USA ANSI B93./NFPA standard. 12 Heading electrical flag symbol M Features and options for pilot valve 13 Electrical data and connection type Plug connector type to ISO 4400 (DIN 43650). For coil characteristics see "Operating Data" table (page B.8): U-G For use with amplifier with 12V DC supply U-GP For use with 12V power U-H For use with amplifier with 24V DC U-HA supply For use with 24V power plug U-HR For use with 800 mA power supply 14 Pilot drain pressure 1 Standard (See Pilot Drain Application Notes, page B.9) 15 Design number, ** series Subject to change. Installation dimensions unaltered for design numbers 10 to 19 respectively. 20 design only for size 7. B.6 Spool Data Spool Symbols Simplified symbols including transient flow conditions {dotted line). Spool Types and Flow Ratings Symmetric Spools Flow ratings for flow through P-A-8-T at ~p = 5 bar (72 psi) per flow path, e.g. P-A, or B-T. For other pressure drop values see "Flow Gain" curves on page B.10. Spool type 2C I~x1:nA~B~~1::~I PT Spool type 7C AB ~X l½l)f-{11~111 PT Spool type 12C AB $fE~*lf~~ PT Spool code For KDG5V-5 valves: 2C90N 33C80N For KDG5V-7 valves: 2C230N 33C230N 36C185N For KDG5V-8 valves: 2C330N 33C330N For KDG5V-10 valves: 2C550N 12C550N 33C550N 133C550N Main stage spool symbol 2C 33C 2C 33C 36C 2C 33C 2C 12C 33C 133C Flow rating 90 L/min (24 USgpm) 80 L/min (21 USgpm) 230 L/min (61.3 USgpm) 230 L/min (61.3 USgpm) 185 L/min (48.9 USgpm) 330 L/min (87.2 USgpm) 330 L/min (87.2 USgpm) 550 L/min (145 USgpm) 550 L/min (145 USgpm) 550 L/min (145 USgpm) 550 L/min (145 USgpm) Spool type 33C AB SpSopoolotlytpyepe333C6C Spool type 133C, with typical regenerative circuit p T Full flow Restricted flow Asymmetric Spools Figure preceding metering type designator, "N" (e.g. 2C***N) is flow rating P-A, or A-T ("A" port flow); figure after "N" (N***) is flow rating P-8, or B-T (''B" port flow). Spool code Main stage spool symbol Flow rating For KDG5V-5 valves: 2C70N45 33C60N40 2C 70 L/min (18.5 USgpm), "A" port flow 45 L/min (12 USgpm), "B" port flow 33C 60 L/min (15.85 USgpm), "A" port flow 40 L/min (10.56 USgpm), "B" port flow For KDG5V-7 valves: 2C230N140 33C230N140 2C 230L/min (61.3 USgpm), "A" port flow 140 L/min (37.3 USgpm), "B" port flow 33C 230L/min (61.3 USgpm), "A" port flow 140 L/min (37.3 USgpm), "B" port flow For KDG5V-8 valves: 33C330N200 133C330N200 2C330N200 For KDG5V-10 valves: 2C310N550 2C550N310 33C310N550 33C550N310 133C550N310 733C550N310 33C 133C 2C 2C 2C 33C 33C 133C 7 33C 330 L/min (87.2 USgpm), "A" port flow 200 L/min (52.8 USgpm), "B" port flow 330 L/min (87.2 USgpm), "A" port flow 200 L/min (52.8 USgpm), "B" port flow 330 L/min (87.2 USgpm), "A" port flow 200 L/min (52.8 USgpm), "B" port flow 310 L/min (82 USgpm), "A" port flow 550 L/min (145 USgpm), "B" port flow 550 L/min (145 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow 310 L/min (82 USgpm), "A" port flow 550 L/min (145 USgpm), "B" port flow 550 L/min (145 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow 550 L/min (145.3 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow 550 L/min (145.3 USgpm), "A" port flow 310 L/min (82 USgpm), "B" port flow B. 7 Operating Data Data is typical: With fluid at 36 cSt (168 SUS) and 50_C (122_F). Using recommended Vickers by Danfoss amplifier to drive KDG5V models. KDG5V valves Installation and Start-up Guidelines Max. solenoid current Coil type: U-G U-GP U-H U-HA U-HR Coil resistance Coil type: U-G U-GP U-H U-HA U-HR Coil inductance measured at 1000 Hz and 150 mV Coil type: U-G U-GP U-H U-HA U-HR Hysteresis Size 5/7/8 Size 10 Repeatability: Size 5/7/8 Size 10 Relative duty factor Type of electrical protection, with electrical plugs fitted correctly Electrical connection Recommended drive amplifier ML-B-9044 3.5A 3.0A 1.6A 0.94A 0.8A At 20_C (68_F) 1.65 2.0 7.3 22.1 19.1 2.66 3.1 11.3 34.6 29.9 Max. operating Shift under max. operating 4 mH 6 mH 19 mH 55 mH 51 mH "4% of rated max. flow Size 5/7/8 <6% of rated max. flow Size 10 <3% 8% Continuous rating (ED = 100%) IEC 144 Class IP65 ISO 4400 (DIN 43650) Vickers Eurocard type: EEA-PAM-523-A-33 B.8 Performance Characteristics Data is typical with fluid at 36 cSt (168 SUS) and 50_C (122_F), using Vickers by Danfoss recommended amplifier to drive KDG5V models. Minimum Pressure For full flow performance pilot pressure w45 bar (650 psi), i.e.: Pressure at port P for internal pilot supply ("X" or omit in model code). Pressure at port X for external pilot supply ("E" or "EX" in model code). Pilot Drain Application Notes External pilot drain is to recommended configuration. Internal pilot drain is possible where a stable "T" port pressure, not exceeding 8 bar (116 psi), can be guaranteed. Any pressure surges at the "T" port (drain) will cause the main spool to move and change the valve output. This possibility is eliminated by the use of an external drain. Maximum Pressures, bar (psi) For models without integral pilot pressure reducer Model Pilot Pressure Source Model code 7 P,A,B KDG5V-5 KDG5V-7/8 KDG5V-10 External Internal External Internal External Internal E Omit E Omit E Omit 315 (4500) 200D (2900) 350 (5000) 200D (2900) 350 (5000) 200 (2900) Ports T X 210 (3000) 210 (3000) 350 (5000) 350 (5000) 350 (5000) 350* (5000) 200 (2900) z 200 (2900) z 210 (3000) z YG 8 (116) 8 (116) 8 (116) 8 (116) 8 (116) 8 (116) For models with integral pilot pressure reducer KDG5V-5 External EX 315 (4500) Internal X KDG5V-7/8 External EX Internal X KDG5V-10 External EX 315 (4500) 350 (5000) 315D (4500) 350 (5000) Internal X 315 (4500) 210 (3000) 210 (3000) 350 (5000) 350 (5000) 350* (5000) 350 (5000) 315 (4500) z 315 (4500) z 315 (4500) z 8 (116) 8 (116) 8 (116) 8 (116) 8 (116) 8 (116) zWhen using internal pilot pressure, port X should be plugged at the subplate or manifold face (e.g. manifold not drilled for connection to port X). D The maximum pressure for ports A and B is: 315 bar (4500 psi) for size 5; 350 bar (5000 psi) for sizes 7, 8 and 10. G See "Pilot Drain Application" note. *Pilot must be externally drained, otherwise "Y" port pressure applies. B.9 Performance Curves Flow Gain Flow gain curves at stated values of total valve pressure drop, for flow P-A-B-T, or P-B-A-T. KDG5V-5-2C90N USgpm L/min 80 300 KDG5V-5-33C80N USgpm L/min 80 300 100 bar (1450 psi) 60 200 50 bar (725 psi) 60 200 40 100 20 30 bar (435 psi) 20 bar (290 psi) 10 bar (145 psi) 40 100 20 100 bar (1450 psi) 50 bar (725 psi) 30 bar (435 psi) 20 bar (290 psi) 10 bar (145 psi) Flow rate Flow rate 0 0 20 40 60 80 100 % of demand signal 0 0 20 40 60 80 100 % of demand signal KDG5V-7-2C230N @ 10 bar (145 psi) A-T P-B ""- :s: 0 u::: -1 00 -80 Umin 300 I 25 0 I 20 0 I "'' \ 15 0 I 10 0 I " 50 .......--- I0 -60 -40 -20 0 i..,.-IP' i,_.., 20 40 % of demand signal P-A B-T l/4 1/ ~, 60 80 100 KDG5V-7-33C230N @ 10 bar (145 psi) Umin -- A-T I - P-B I A v,::: P-A B-T a, :s: u0::: Iv A /4 t1/ V I -A Io I ~' I 0,_ i...- 1,./ -100 -80 -60 -40 -20 0 20 40 60 80 100 % of demand signal KDG5V-7-36C18SN @ 10 bar (145 psi) Umin A-T P-B ::::::: 2 :s: u0::: -100 30 0 I 25 0 I 20 0 I , "'I". i,,,. ..... 150 I 100 I '-4. ....... 50 0 / i,...-... _i,..-" -80 -60 -40 -20 0 20 40 % of demand signal P-A V V B-T v V / 60 80 100 KDGSV-8-2C330N Umin 800 700 600 2 500 I 400 d'. 300 200 100 0 I 0 -- ---- - -i.-- 20 40 60 80 % of demand signal - 10 bar (145 psi) 100 KDGSV-8-33C330N Umin 800 700 600 2 500 400 d'. 300 200 100 0 0 -- ~--- - ....--- L-,..-- - 10 bar (145 psi) - 20 40 60 80 100 % of demand signal B.10 Performance Curves Asymmetric Spools KDGSV-5-2C70N45 @ 5 bar ti P Umin 150 125 2 100 ;: 75 0 U::: 50 25 0 0 -- -------- / ..... ---- t.----""""" P-A,A-T P-B , B-T 20 40 60 80 100 % of demand signal KDGSV-5-33C60N35 @ 5 bar ti P Umin 150 125 2 100 ;: 75 0 U::: 50 I 25 0 0 - --- -- -- i---- P-A,A -T - i-- P-B, B-T 20 40 60 80 100 % of demand signal KDGSV-7-33C230N140 @ 10 bar (145 psi) U min 300 I 250 A-T r---- I 200 I ""' ' P-B r--r---......... ...... 150 I r----1r"--'..-........_F:1::50:IE00 ::k / P-A V /v .,,,,,. B-T ,_,/ / V V V-V ,, - -- - 0 _,:::::::i:;--- ~ ·--- -1 00 -80 -60 -40 -20 0 20 40 60 80 100 % of demand signal KDGSV-8-2C330N200 @ 5 bar delta P Umin 800 700 I 600 2 500 I ;: 400 ct'. 300 200 100 0 I 0 -- --- - P-A -- - L--- --- - - -~ P-B 20 40 60 80 100 % of demand signal KDGSV-8-33C330N200 @ 5 bar delta P Umin 800 700 600 2 500 ;: 400 ct'. 300 200 100 0 --- ---- -- -- - -- - P-A P-8 0 20 40 60 80 100 % of demand signal KDGSV-8-133C330N200 @ 5 bar delta P L/min 800 700 I 600 I 2 500 ;: 400 ct'. 300 200 100 I 0 I 0 -- ----L..-- - -~ i--- c-- - P-A P-8 20 40 60 80 100 % of demand signal B.11 Flow rate KDG5V-10 USgpm L/min 400 1600 300 1200 200 800 100 600 0 200 0 100 bar (1500 psi) V 50 bar (725 psi) V V / V / // / V 20 bar (290 psi) /v/ / / / I/ / 1/ V / / / ,..-::-::::-,,,,:::::.1/~ 10 bar (145 psi) 20 40 60 80 100 % of maximum solenoid current Power Capacity Envelopes Flow through P-A-B-T or P-B-A-T bar 350 300 250 ea. "O !':' 200 :, Ln > I Ln l9 ""!':''' 0 a. 150 (1) ..::: 100 I' 00 > I Ln > I Ln l9 l9 0 0 50 0 0 200 Typical Step Response Test conditions: No pressure reducer module Flow P-A-B-T Total valve Dp = 10 bar (145 psi) Pilot pressure = 50 bar (725 psi) "Response" = Time, from step response signal, until output reaches 90% of step change value Input signal step change 0 to 100% 100% to 0 10% to 90% 90% to 10% 25% to 75% 75% to 25% 90% to 90% 0% to 75% 75% to 0% 0% to 50% 50% to 0% 0% to 25% 25% to 0% 400 600 Flow rate 800 1000 Umin Subject to maximum pressure limitations according to model type; see "Maximum Pressures". Spool response times (ms) KDG5V-5 KDG5V-7 KDG5V-8 KDG5V-10 48 61 38 43 42 58 50 58 30 47 50 58 70 87 80 206 40 182 66 54 49 66 98 170 175 160 160 124 124 B.12 Pilot flow required to achieve above response times: KDG5V-5 2,7 L/min (0.7 USgpm) KDG5V-7 4,2 L/min (1.1 USgpm) KDG5V-8 7,5 L/min (2.0 USgpm) KDG5V-10 18,75 L/min (5.0 USgpm) Installation Dimensions KDG5V Models with "EX" or "X" (With integral pilot pressure reducer) The illustration is correct for KDG5V-7 valves Dimensions are shown in mm (inches) 0 E e> 4.§.0(1 .81 ) ci g, 0 C. M 0 LL @-E} 3rd angle projection 233.8 9.2 (Max. length of KDG5V-5 model s) r- 219.3 ~ 65.0 2.6 _ _J For coil removal -11A.ldQd _(QM)_ for manual - 1 override : options I I I I I I I I I ---- I Cl i --1-- @!@ I: 13 :I PORT A C j D E F B "G" dimension is depth of bolt holes. (On KDG5V-7 only, this coincides with the height to the center line of the main-stage spool). KDG5V Models with "E" or No Symbol (Without integral pilot pressure reducer) Model KDG5V-5 KDG5V-7 KDG5V-8 A1 215,0 (8.47) 215,4 (8.48) 255,0 (10.1) A2 175,0 (6.9) 176,9 (6.9) 215,0 (8.47) B 70, (2.77) 92 (3.62) 114,8 (4.52) C 94,4 (3.72) 105 (4.13) 118,4 (4.66) D 27,0 (1.06) 50,0 (1.97) 77,0 (3.03) I I I I I I ,I , ,I I I I I E 98, (3.86) 122,2 (4.8) 185,0 (7.28) F 217,0 (8.54) 269,0 (10.6) 332,0 (13.1) G 30,0 (1.18) 33,0 (1.3) 59,0 (2.32) H 87,3 (3.4) 95,0 (3.7) 127,2 (5.0) B.13 KDG5V-10 Models with "EX" or "X" (With integral pilot pressure reducer) Dimensions are shown in mm (inches) -$--8 3rd angle projection 76,2 (3.00) ------ 190,5 (7.50) I --+-----1 -- 79,2 (3.12) t t 196,8 (7.75) 98,6 (3.88) ~' 1-------------- 158,8 (6.25) 194,3 (7.65) l40,0 (1.57) I t 284,5 (11.2) 193,5 @ (7.62) @ @ _j ------i 196,8 (7.75) 516,9 (20.35) -85,3 (3.36) 7 125,2 (4.93) i .I B.14 Pilot Supply and Drain Plugs KDG5V-5 models Viewed from port B end of main-stage M5 plug, part no. 471119. Remove for internal pilot supply \Pilot connections PT M5 plug, part no. 471119. Remove for internal pilot drain KBDG5V-7 Models Viewed from port A end of main stage MS plug, part no. 471119. Remove for interna l Pilot supp ly MS plug, part no. 471119. Remove for internal Pilot drain * Internal plug shown, for external pilot supply (via port X). For internal pilot supply (from port P) plug is not fitted. Port X should be blocked at mounting interface, or otherwise plugged at subplate of manifold block. See "Model Code". KDG5V-8 models Section through port P of main-stage M5 plug, part no. 471119. Remove for internal pilot drain KDG5V-10 models Plug, part no. 7074. Remove for internal pilot drain 1/16 NPT plug, part no. 113000. Remove for internal pilot supply P Plug, part no. 30560 for internal pilot drain, part no. 7074 for external pilot drain. Plug, part no. 30560. Remove for internal pilot drain B.15 Views on Mounting Faces All O-seals supplied KDG5V-5 mounting face KDG5V-7 mounting face T AB T A B X Y P 4 holes for mounting bolts Ø 7,02 (0.27Ø ) spotfaced to Ø 11,0 (0.43 Ø) A B Y T P X 6 holes for mounting bolts 4 x Ø 11,0 (0.43 Ø) c'bored Ø 17,5 (0.68 Ø) 2 x Ø 6,4 (0.25 Ø) c'bored Ø 11,0 (0.43 dia) KDG5V-8 mounting face X T A B P Y 6 holes for mounting bolts Ø 13,5 (0.53 Ø) spotfaced to Ø 20,0 (0.78 Ø) KDG5V-10 mounting face A X WT B P Y 6 holes for mounting bolts B.16 Electrical information Eurocard Power Amplifier Recommended to use Vickers by Danfoss Eurocard amplifiers with KDG5V valves. Electrical Block Diagram EEA-PAM-523-A-33 -, I L_ ,., MP2 _J Wiring Connections Amplifier model 523 for KDG5V-5,7,8,10 t=-='-"-)--+-------------------7 -- I I £-==-==~----=----=-==171: I -- I :I I I~ Customer's protective ground connection B.17 Application Data Hydraulic fluids and fluid cleanliness Recommendations on contamination control methods and the selection of products to control fluid condition are included in Hydraulic Fluid Recommendations. For products in this catalog the recommended levels are: 0 to 70 bar (1000 psi) 18/16/13 70 + bar (1000 + psi) 17/15/12 Hydraulic fluids Materials and seals used in these valves are compatible with anti-wear hydraulic oils, and non-alkyl-based phosphate esters. The extreme operating viscosity range is 500 to 13cSt (2270 to 70 SUS) but the recommended running range is 54 to 13cSt (245 to 70 SUS). For further technical information about fluids see "Technical Information" leaflet B-920 or I-286S. Installation The proportional valves in this catalog can be mounted in any attitude, but it may be necessary in certain demanding applications, to ensure that the solenoids are kept full of hydraulic fluid. Good installation practice dictates that the tank port and any drain port are piped so as to keep the valves full of fluid once the system start-up has been completed. Mounting bolt kits Pilot with reducer metric inch BK464125M BK870017 KDG5V-5 Mainstage metric inch BKDG01633M BKDG01633 KDG5V-7 Mainstage metric inch BKDG7858918 BK590724 KDG5V-8 Mainstage metric inch BKDG8-655M BKDG06-635 KDG5V-10 Mainstage metric inch BKDG10636M BKDG10636 If not using Vickers recommended bolt kits, bolts used should be to ISO 898, 12.9 or better. Mounting bolt torques Recommended torques with threads lubricated For KDG5V-5 M6 or 1/4 " -20 UNC bolts: To 210 bar (3000 psi) 14 Nm (10.3 lbf ft) To 315 bar (4500 psi) 20 Nm (14.75 lbf ft) For KDG5V-7 M10 or 3/8" -16 UNC bolts: 49 to 59 Nm (36 to 43 lbf ft) plus M6 or 1/4" -20 UNC bolts: 9 to 14 Nm (6.6 to 10.3 lbf ft) For KDG5V-8 M12 or 1/2"-13 UNC bolts: 103 to 127 Nm (76 to 93 lbf ft) For KDG5V-10 M20 or 3/4"-10 UNC-2B bolts: 185-220 Nm (250-300 lbf ft) Seal Kits Pilot including M8 cap 5986617-001 Reducer 870739 KDG5V-5 Mainstage 565143 Complete valve 5986818-001 KDG5V-7 Mainstage 565144 Complete valve 5986819-001 KDG5V-8 Mainstage 5986821-001 Complete valve 5986820-001 KDG5V-10 Mainstage Mainstage Complete valve 02-441686 02-441691 Mass (Weight) Approx. for models with integral pilot pressure reducing module ("X" or "EX"see mode code). KDG5V-5 9,5 kg (21 lb) KDG5V-7 11,8 kg (26.0 lb) KDG5V-8 20,2 kg (44.5 lb) KDG5V10 54,5 kg (120.0 lb) For models without integral pressure reducing module (No symbol, or "E", see model code), deduct 1,2 kg (2.6 lb). Service information The products from this range are preset at the factory for optimum performance; disassembling critical items would destroy these settings. It is therefore recommended that should any mechanical or electronic repair be necessary they should be returned to the nearest Danfoss repair center. The products will be refurbished as necessary and retested to specification before return. B.18 by Danfoss Danfoss 14615 Lone Oak Road Eden Prairie, MN 55344-2287 USA Tel: (+1) 952 937-9800 Fax: (+1) 952 974-7722 Danfoss 20 Rosamond Road Footscray Victoria 3011 Australia Tel: (+61) 3 9319 8222 Fax: (+61) 3 9318 5714 © 2023 Danfoss Corporation All Rights Reserved Printed in USA Document No. 5052/EN/1097/A - rev2 Asset ID: BC451469581724en-000102 May 2023 Danfoss 46 New Lane, Havant Hampshire PO9 2NB England Tel: (+44) 23 9248 6451 Fax: (+44) 23 9248 7110Danfoss A/S GPL Ghostscript 10.03.1