User Manual for HTC models including: PM-6175 Manometer, PM-6175, Manometer
Get Manometer PM-6115 Online Now | HTC Instrument
3 4. Specification unit PM-6102 PM-6105 PM-6115 Range Resolution Range Resolution Range Resolution inH2O ±55.40 0.01 ±138 0.1 ±415.2 0.1
File Info : application/pdf, 12 Pages, 3.41MB
DocumentDocumentUser's Manual HTC Manometer Please read this user's manual thoroughly before using this unit and keep it properly for your future reference. Contents 1. Safety........................................................................................... 1 2. Introduction............................................................................... 2 3. Error Warning............................................................................ 2 4. Specification .............................................................................. 3 5. Meter Description .................................................................... 5 6. LCD display ................................................................................ 6 7. Operation steps ........................................................................ 6 8. Buttons function....................................................................... 6 9. Notes ........................................................................................... 8 10. Accessories .............................................................................. 8 1. Safety Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. Environment conditions: 1) RH90Non-Condensation 2) Operating Temperature-040 Maintenance and cleaning 1) Repairs or servicing not covered in this manual should only be performed by qualified personnel. 2) Wipe the unit with a dry soft cloth. Do not use solvents or detergents on this instrument. Safety Symbol Comply with EMC 1 2. Introduction This product is aimed to measure different pressure values, here are some units for Choice: inH2O, psi ,bar, mbar , kPa, inHg, mmHg ,ozin2 ,,ftH2O, cmH2O ,kgcm2.equipped with simple Tube connection. It is widely used in measurement of ventilation and air conditioning system, clean room or any gas pressure system troubleshooting .Easy operation and clear reading. 3. Error Warning When internal diagnostic test fails, an error message will appear on the LCD display. error1 max pressure error2 below min pressure 2 4. Specification unit inH2O Psi Mbar KPa inHg mmHg PM-6102 PM-6105 PM-6115 Range ±55.40 ±2.000 ±137.8 Resolution 0.01 0.001 0.1 Range ±138 ±5.000 ±344.7 Resolution 0.1 0.001 0.1 Range ±415.2 ±15.00 ±1034 Resolution 0.1 0.01 1 ±13.79 ±0.407 ±103.4 0.01 0.001 0.1 ±34.47 ±1.018 ±258.5 0.01 0.001 0.1 ±103.4 ±30.54 ±775.7 0.1 0.01 0.1 ozin² ±32.00 0..01 ±80 1 ±240.0 0.1 ftH2O ±4.612 0.001 ±11.53 0.01 ±34.60 0.01 cmH2O ±140.6 0.1 ±351.5 0.1 kgcm² ±0.140 0.001 ±0.351 0.001 bar ±0.137 0.001 ±0.344 0.001 Maximum Pressure Psi 10 Psi 20 Psi Accuracy Linearity/Hysteresis Repeatability Pressure connector Working temperature ±0.3%FS ±0.1%FS ±0.25%FS 1/83.18mmquick connector 040/32104 Storage temperature -1060/14140 Over range indication Work current ERR1 or ERR2 9V battery ±1055 1 ±1.055 0.001 ±1.034 0.001 100 Psi 3 unit PM-6130 PM-6175 Range Resolution Resolution Range inH2O ±830 Psi ±30.00 Mbar ±2608 KPa ±206.8 inHg ±61.08 mmHg ±1551 ozin² ±480.0 ftH2O ±69.2 cmH2O ±2109 kgcm² ±2.109 bar ±2.068 Maximum Pressure Psi 1 0.01 1 0.1 0.01 1 0.1 0.01 1 0.001 0.001 100Psi ±2078 ±75.00 ±5168 ±517.1 ±15.00 ±3878 ±1200 ±173.0 ±5272 ±5.250 ±5.138 100Psi 1 0.01 1 0.1 0.01 1 0.1 0.01 1 0.001 0.001 accuracy Linearity/Hysteresis Repeatability Pressure connector Working temperature Storage temperature Over range indication Work current ±0.3%FS ±0.1%FS ±0.25%FS 1/83.18mmquick connector 040/32104 -1060/14140 ERR1 or ERR2 9V battery 4 5. Meter Description Air intake LCD Display Power key Backlight key Unit key Hold button record key 6. LCD display Data record Record mode Max Min, Avg Readings Unit Low battery indication Memory time 5 7. Operation steps 7.1 Open battery cover and install a 9-volt battery in the battery compartment. Press power key to start measuring 7.2 press UNITS keychoosing proper unit 7.3 connect Tube 7.4 read the testing values on LCD display Note when the meter is on, no gas pressure input, the meter will not necessarily be zero, you need to reset by yourself. 8. Buttons function 8.1 Keyit can turn on and turn off the meterpress" ", open manometer, the screen will display about 2 seconds, and then enter normal measurement model. 8.2 Keyafter power on the meterpressing this button can turn on and turn off the backlight. 8.3 Keyin measurement modepress" ", it can review Max ,Min, Avg values. In this mode, other button functions are locked not operated. Press 6 " "for three secondsthe meter exits record model. 8.4 keyafter power on the meterpress" "it can convert the units of measurementbar,mmHg,Ozin2,Kgcm2,psi,inH2O,Kpa,ft H2O,inHg,cmH2O,mbar. 8.5 key 8.5.1 After the meter power onpress" "button oncethe screen will be locked, press" "againit will cancel this function. 8.5.2 After power on the meterno gas pressure inputpress" "for three secondsLCD screen display"----"the meter reset. 8.6 Automatically power on/off the meter will automatically turn off after approx. 25 minutes of inactivity. It can save battery's life. If you do not want to turn off, first press ,then press ,"ON "will appear on the LCD display, it indicates that power off function is disabled. 7 9. Notes 1. Do not use it in high temperature and humidity 2. Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage. 3. Replace new batteries when the low battery icon " " appears. 10. Accessories Manual Canvas ba 6F22 9V battery 4.5mm mental gas mouth 2 PCS 5.0mm*30mm soft Tube 2PCS 5.0mm*30mm hard Tube 2PCS www.htcinstrument.com 8