Haier Outdoor Units for Multi-Split Air Conditioning Systems
This document provides detailed specifications for Haier's range of outdoor units designed for multi-split air conditioning systems. The units offer various cooling and heating capacities to suit different needs.
Product Range Overview
Haier offers a selection of outdoor units with capacities ranging from 4.0 kW to 12.5 kW, suitable for multi-split configurations. The available models are designed with inverter technology for efficient operation.
Performance Data and Specifications
MODEL | 2U40S2SM1FA | 2U50S2M1FA-3 | 3U55S2SR5FA | 3U70S2SR5FA | 4U75S2SR5FA | 4U85S2SR5FA | 5U90S2SS5FA | 5U105S2SS5FA | 5U125S2SN1FA | 3U55S2WR1FA | 4U70S2WR1FA |
---|---|---|---|---|---|---|---|---|---|---|---|
Output power - COOLING (nom) kW | 4,0 (1,10-4,50) | 4,60 (1,30-6,00) | 5,50 (2,10-7,00) | 7,00 (2,40-7,60) | 7,50 (2,40-8,70) | 8,50 (3,20-9,50) | 9,00 (3,20-11,00) | 10,00 (3,20-11,00) | 12,50 (3,20-13,80) | 5,40 | 7,00 |
Output power - HEATING (nom) kW | 4,40 (1,50-4,80) | 5,20 (1,60-6,50) | 6,80 (1,70-7,60) | 7,60 (2,90-8,50) | 8,60 (3,10-10,00) | 9,60 (4,40-10,50) | 10,40 (4,40-11,50) | 10,50 (4,40-11,50) | 12,70 (4,40-14,30) | 6,30 | 7,00 |
Absorbed power - COOLING (nom) kW | 0,89 (0,30-1,65) | 1,07 (0,35-2,01) | 1,35 | 1,84 | 1,97 | 2,50 | 2,79 | 3,47 | 3,87 | 1,34 | 1,8 |
Absorbed power - HEATING (nom) kW | 0,98 (0,38-1,80) | 1,21 (0,52-2,00) | 1,66 | 1,85 | 2,15 | 2,40 | 2,79 | 2,82 | 3,40 | 1,68 | 2,0 |
EER W/W | 4,50 | 4,3 | 4,00 | 3,81 | 3,80 | 3,40 | 3,23 | 2,88 | 3,23 | 4,05 | 3,90 |
COP W/W | 4,50 | 4,3 | 4,10 | 4,10 | 4,00 | 4,00 | 3,73 | 3,73 | 3,73 | 4,20 | 4,30 |
COOLING Pdesign (35 °C) kW | 4,00 | 4,60 | 5,50 | 7,00 | 7,50 | 8,00 | 9,00 | 10,00 | 12,50 | 5,4 | 7,0 |
HEATING Pdesign (-10 °C) kW | 3,70 | 3,80 | 4,70 | 6,00 | 5,0 | 6,0 | 7,00 (A++) | 7,00 (A++) | 7,10 (A++) | 7,00 (A++) | 7,10 (A++) |
SEER | 8,50 (A+++) | 8,50 (A+++) | 8,50 (A+++) | 7,50 (A++) | 7,00 (A++) | 8,5 (A+++) | 8 (A++) | 8 (A++) | 8,5 (A+++) | 7,00 (A++) | 7,10 (A++) |
SCOP | 4,60 (A++) | 4,60 (A++) | 4,00 (A+) | 4,20 (A+) | 4,00 (A+) | 4,00 (A+) | 4,00 (A+) | 4,00 (A+) | 4,05 (A+) | 4,6 (A++) | 4,3 (A+) |
Annual Energy Consumption - COOLING kWh/a | 165 | 189 | 227 | 332 | 379 | 456 | 457 | 537 | 622 | 240 | 320 |
Annual Energy Consumption - HEATING kWh/a | 1126 | 1157 | 1678 | 2012 | 2179 | 2503 | 2441 | 2889 | 3346 | 1680 | 1922 |
Outdoor Unit Specifications
2U40S2SM1FA | 2U50S2M1FA-3 | 3U55S2SR5FA | 3U70S2SR5FA | 4U75S2SR5FA | 4U85S2SR5FA | 5U90S2SS5FA | 5U105S2SS5FA | 5U125S2SN1FA | 3U55S2WR1FA | 4U70S2WR1FA | |
---|---|---|---|---|---|---|---|---|---|---|---|
Power supply Ph/V/Hz | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 | 1/220~240/50/60 |
Power cable N x mm2 | 3 x 2,5 | 3 x 2,5 | 3 x 4,0 | 3 x 4,0 | 3 x 4,0 | 3 x 4,0 | 3 x 4,0 | 3 x 4,0 | 3 x 4,0 | 3 x 4,0 | 3 x 4,0 |
Interconnection cable N x mm2 | 4 x 1,0 | 4 x 1,0 | 4 x 2,5 | 4 x 2,5 | 4 x 2,5 | 4 x 2,5 | 4 x 2,5 | 4 x 2,5 | 4 x 2,5 | 4 x 2,5 | 4 x 2,5 |
Air volume m³/h | 2200 | 2400 | 3000 | 3000 | 4000 | 4000 | 4200 | 4200 | 4200 | 3000 | 3000 |
Sound power dB | 62 | 63 | 64 | 66 | 68 | 68 | 70 | 70 | 73 | 63 | 63 |
Sound pressure dB(A) | 56 | 56 | 51 | 53 | 55 | 55 | 55 | 55 | 58 | 53 | 53 |
Running current cooling/heating Max A | 7,4/8,2 | 9,0/8,9 | 10,8/9,5 | 11,9/9,7 | 14,7/13,5 | 15,5/14,6 | 18,2/14,6 | 18,2/14,6 | 23,0/18,7 | 12,6/11,5 | 13/12 |
Starting current cooling/heating Max A | 1,0/1,0 | 1,0/1,0 | 4,0/4,0 | 4,0/4,0 | 5,0/5,0 | 5,0/5,0 | 5,0/5,0 | 5,0/5,0 | 5,0/5,0 | 4,0/4,0 | 4,0/4,0 |
Net dimensions WxDxH mm | 800x280x550 | 800x280x550 | 890x340x700 | 890x340x700 | 890x340x700 | 890x340x700 | 920x372x765 | 920x372x765 | 1010x455x835 | 890x340x700 | 890x340x700 |
Packaging dimensions WxDxH mm | 908x405x625 | 908x405x625 | 1010x455x835 | 1010x455x835 | 1010x455x835 | 1010x455x835 | 1045x488x890 | 1045x488x890 | 1050x485x1170 | 1010x455x875 | 1045x488x890 |
Net/gross weight kg | 34,0/37,0 | 36,0/39,0 | 50,0/59,0 | 54,0/63,0 | 61,0/70,0 | 66,0/77,0 | 79,0/91,0 | 55/65 | 56/66 | 55/65 | 56/66 |
Compressor type | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary Inverter | Twin Rotary (DC inverter) | Twin Rotary (DC inverter) |
Installation Data
2U40S2SM1FA | 2U50S2M1FA-3 | 3U55S2SR5FA | 3U70S2SR5FA | 4U75S2SR5FA | 4U85S2SR5FA | 5U90S2SS5FA | 5U105S2SS5FA | 5U125S2SN1FA | 3U55S2WR1FA | 4U70S2WR1FA | |
---|---|---|---|---|---|---|---|---|---|---|---|
Refrigerant | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
Liquid pipe Ø mm (inch) | 2×6,35 (3x1/4) | 2×6,35 (3x1/4) | 3×6,35 (3x1/4) | 3×6,35 (3x1/4) | 4×6,35 (4x1/4) | 4×6,35 (4x1/4) | 5×6,35 (5x1/4) | 5×6,35 (5x1/4) | 5×6,35 (5x1/4) | 3*06,35 (3x1/4) | 4*06,35 (4x1/4) |
Gas pipe Ø mm (inch) | 2x9,52 (3x3/8) | 2x9,52 (3x3/8) | 3×9,52 (3x3/8) | 3×9,52 (3x3/8) | 3×9.52+1×12,70 (3x3/8+1x1/2) | 3×9.52+1×12,70 (3x3/8+1x1/2) | 3×9,52+2×12,70 (3x3/8+2x1/2) | 3×9.52+2×12,70 (3x3/8+2x1/2) | 3×9.52+2×12,70 (3x3/8+2x1/2) | 3*09,52 (3x3/8) | 4*09,52 (3x3/8) |
Standard pipe length without refrigerant charge m | 20 | 20 | 30 | 30 | 40 | 40 | 40 | 40 | 50 | 30 | 30 |
Maximum pipe length m | 20 (single) 30 (double) | 20 (single) 30 (double) | 50 | 50 | 70 | 70 | 80 | 80 | 100 | 50 | 50 |
Maximum IU - OU elevation m | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Maximum IU - IU elevation m | 7,5 | 7,5 | 7,5 | 7,5 | 7,5 | 7,5 | 7,5 | 7,5 | 7,5 | 7,5 | 7,5 |
Refrigerant charge in the factory kg | 1,00 | 1,10 | 1,40 | 1,60 | 1,60 | 2,20 | 2,40 | 2,40 | 2,50 | 1,8 | 1,9 |
Refrigerant charge in the factory TCO2eq | 0,68 | 0,74 | 0,95 | 1,08 | 1,08 | 1,49 | 1,62 | 1,62 | 1,69 | 1,22 | 1,28 |
Additional ref. charge over std length g/m | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Operating limits - COOLING (in/out) °C | -10~43°C | -10~43°C | -10~46°C | -10~46°C | -10~46°C | -10~46°C | -10~46°C | -10~46°C | -10~46°C | -10~46°C | -10~46°C |
Operating limits - HEATING (in/out) °C | -15~24°C | -15~24°C | -15~24°C | -15~24°C | -15~24°C | -15~24°C | -15~24°C | -15~24°C | -15~24°C | -15~24°C | -15~24°C |
Note: Data combination based on Haier Expert Unit. Data may vary with other indoor units. The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.