Honeywell MultiRAE
Portable Six-Gas Monitor with Advanced VOC Detection Capability
The MultiRAE is the most advanced portable chemical detector on the market. The MultiRAE offers the widest range of class-leading PID sensors and the versatility to support 25 interchangeable smart sensor options (including PID, NDIR for combustibles and CO₂, ammonia, chlorine, formaldehyde, and phosphine) to fully meet the monitoring needs in a variety of applications, including industrial hygiene, personal protection, leak detection, and hazardous material response.
The optional wireless capability of the MultiRAE enhances safety by providing commanders and safety officers with real-time access to instrument readings and alarm status from any location¹ for improved situational awareness and faster incident response.
Applications
Industrial hygiene, personal protection, and leak detection in industries such as:
- Aviation (wingtankentry)
- Oil and gas
- Transportation/marine
- Hazardous materials response
- Illicit drug laboratories
Features and Benefits
- Highly versatile and customizable
- Best-in-class PID (0 to 5,000 ppm range, 0.1 ppm resolution)
- Real-time remote wireless man-down alarm notification
- Complies with MIL-SPEC-810G performance standard
- Fully automatic bump test and calibration with AutoRAE 2
- Extensive onboard continuous datalogging (190 VOCs, 6 months of data for 5 gases, 24x7)
- Large display in its class with Honeywell SafetySuite device management
Specifications
Instrument Specifications
- Size: 7.6" high x 3.8" wide x 2.6" deep (193 x 96.5 x 66 mm)
- Weight: 31 oz (31 g)
- Sensors: 25 interchangeable field-replaceable smart sensors, including PID for VOCs, electrochemical sensors for toxic gases and oxygen, LEL and combustible NDIR sensors, and CO₂ NDIR sensor
- Battery Options: Rechargeable Li-ion (~12 hours runtime, <6 hours recharge), Extended life Li-ion (~18 hours runtime, <9 hours recharge), Alkaline adapter with 4 AA batteries (~6 hours runtime)
- Monitor Display: Monochrome graphic LCD (128 x 160) with backlight. Automatic screen "flip" function.
- Display Readings: Real-time gas concentrations; Gas PID reading and correction factor; Man-down alarm enabled/disabled; visual compliance indicator; battery status; datalogging enabled/disabled; wireless enabled/disabled and reception quality. STEL, TWA, Peak, and Min values.
- Keypad Buttons: 3 operation and programming keys (Mode, Y/+, and N/-)
- Sampling: Built-in pump. Average flow rate: 250 cc/min. Auto shut-off in low flow conditions.
- Calibration: Automatic with AutoRAE 2 test and calibration system or manual.
- Alarms: Wireless remote alarm notification; audible (95 dB @ 30 cm), vibrating, visible (bright red flashing LEDs) and on-screen indication of alarm conditions - Man-down alarm with pre-alarm and real-time remote wireless notification¹
- Datalogging: Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7) - User-configurable datalogging intervals (1 to 3,600 seconds)
- Communication and Data Download: Data download and instrument configuration and update via desktop charger and PC communication base, travel charger, or AutoRAE 2 test and calibration system - Wireless data and alarm status transmission via built-in RF modem (optional)
- Wireless Network: ProRAE Guardian real-time wireless safety system or EchoView host-based closed-loop system
- Wireless Range (Typical): MultiRAE to RAELink3 Mesh Modem ~330 ft (100 m) MultiRAE to EchoView Host, RAEMesh Reader, or RAEPoint ~660 ft (200 m) MultiRAE to Wi-Fi access point ~330 ft (100 m)
- Operating Temperature: -4° to 122°F (-20° to 50°C)
- Humidity, Dust, and Water: 0% to 95% relative humidity (non-condensing) IP-65 rating (dust-tight and protected against water jets from all directions)
- Enclosure: Meets MIL-STD-810G and 461F. LEL CSA C22.2 No. 152; ISA-12.13.01
- Certifications: ATEX: 0575 II 1G Ex ia IIC T4 Ga 2G Ex ia d IIC T4 Gb with IR sensor installed I M1 Ex ia I Ma IECEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR sensor installed I M1 Ex ia I Ma IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR sensor installed Ex ia I Ma
- Languages: German, Arabic, Czech, Danish, Spanish, French, Indonesian, English, Italian, Japanese, Dutch, Polish, Portuguese, Russian, Swedish, and Turkish
- Warranty: Four years on Liq O₂ sensors; Three years on CO and H₂S sensors; Two years on non-consumable components and catalytic LEL sensors; One year on all other sensors, pumps, batteries, and other consumables
- Wireless Frequency: ISM license-free band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
- Wireless Approvals: FCC Part 15, CE R&TTE, Others ⁶
Sensor Specifications
Sensor Type | Range | Resolution |
---|---|---|
VOC 10.6 eV (EXT. RANGE) | 0 to 5,000 ppm | 0.1 ppm |
LEL NDIR CATALYTIC (0-100% LEL METHANE) | 0 to 100% LEL | 1% LEL |
NDIR (0-100% VOL. METHANE) | 0 to 100% Vol. | 0.1% Vol. |
CARBON DIOXIDE (CO₂) NDIR | 0 to 50,000 ppm | 100 ppm |
AMMONIA (NH³) | 0 to 100 ppm | 1 ppm |
CARBON MONOXIDE (CO) | 0 to 500 ppm | 1 ppm |
CARBON MONOXIDE (CO), EXT. RANGE | 0 to 2,000 ppm | 10 ppm |
CARBON MONOXIDE (CO), H₂ COMP.² | 0 to 2,000 ppm | 10 ppm |
CARBON MONOXIDE (CO) + | 0 to 500 ppm | 1 ppm |
HYDROGEN SULFIDE (H₂S) COMBO 2 | 0 to 200 ppm | 0.1 ppm |
SULFUR HYDROGEN (H₂S) | 0 to 50 ppm | 0.1 ppm |
CHLORINE (CL²) | 0 to 10 ppm | 0.03 ppm |
CHLORINE DIOXIDE (CLO²) | 0 to 100 ppm | 0.5 ppm |
ETHYLENE OXIDE (ETO-A) | 0 to 10 ppm | 0.1 ppm |
ETHYLENE OXIDE (ETO-B) | 0 to 10 ppm | 0.05 ppm |
FORMALDEHYDE (HCHO) | 0 to 50 ppm | 0.5 ppm |
HYDROGEN CYANIDE (HCN) | 0 to 100 ppm | 0.1 ppm |
SULFUR HYDROGEN (H₂S) | 0 to 10 ppm | 0.1 ppm |
METHYL MERCAPTAN (CH³SH) | 0 to 250 ppm | 0.5 ppm |
NITRIC OXIDE (NO) | 0 to 20 ppm | 0.1 ppm |
NITROGEN DIOXIDE (NO²) | 0 to 20 ppm | 0.1 ppm |
OXYGEN (O²) | 0 to 30% Vol. | 0.1% Vol. |
OXYGEN (LIQ O²) | 0 to 30% Vol. | 0.1% Vol. |
PHOSPHINE (PH³) | 0 to 20 ppm | 0.1 ppm |
PHOSPHINE (PH³ H) | 0 to 20 ppm | 0.1 ppm |
¹ Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.
² A two-gas sensor is required for a 6-gas configuration.
³ Specifications are subject to change.
⁴ Specification for non-wireless monitors.
⁵ Contact RAE Systems for country-specific wireless approvals and certifications.
Ordering Information
- Model: PGM-6228
- Wireless and non-wireless configurations available
- Consult the Portable Price Guide for monitor part numbers, accessories, sampling and calibration kits, gas, sensors, and spare parts.
Contact Information
For More Information
- www.honeywellanalytics.com
- www.raesystems.com
Americas
- Honeywell Analytics Distribution Inc. Tel: +1 847 955 8200 Toll-free: +1 800 538 0363 detectgas@honeywell.com
- Honeywell RAE Systems Phone: +1 408 952 8200 Toll-free: +1 888 723 4800
Europe, Middle East, Africa
- Life Safety Distribution GmbH Tel: 00800 333 222 44 (Toll-free number) Tel: +41 44 943 4380 (Alternative number) Middle East Tel: +971 4 450 5800 (fixed gas detection) gasdetection@honeywell.com
Asia Pacific
- Honeywell Analytics Asia Pacific Tel: +82 (0) 2 6909 0300 India Tel: +91 124 4752700 China Tel: +86 10 5885 8788-3000 analytics.ap@honeywell.com
Technical Services
- EMEA: HAexpert@honeywell.com USA: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com