Instruction Manual for BEKA models including: BA377E-SS Timer or Clocks, BA377E-SS, Timer or Clocks, Clocks
Abbreviated Instruction manuals
File Info : application/pdf, 2 Pages, 773.53KB
DocumentDocument1. DESCRIPTION The BA377E is an intrinsically safe, panel mounting instrument with a single input that can be configured as a Timer or as a Clock. As a Timer the BA377E is able to measure and display the elapsed time between external events, or control external events via two optional factory fitted control outputs. When configured as a Clock the BA377E displays local time and the optional control outputs can turn on and off twice in each twenty four hour period. This abbreviated instruction sheet is intended to assist with installation, a comprehensive instruction manual describing safety certification, system design and configuration may be downloaded from the BEKA website or may be requested from the BEKA sales office. The BA377E has IECEx, ATEX and UKEX intrinsic safety certification for use in flammable gas atmospheres. ETL and cETL approval permits installation in the USA and Canada. The certification information label, which is located on the top of the instrument enclosure, shows the certification number and codes. Other certifications may be shown. Copies of certificates may be down loaded from the BEKA website. Typical certification information label Special conditions for safe use The IECEx, ATEX and UKEX certificates have an `X' suffix indicating that special conditions apply for safe use. WARNING To avoid an electrostatic charge being generated instrument enclosure should only be cleaned with a damp cloth. 2. INSTALLATION The BA377E has IP66 front of panel protection but it should be shielded from direct sunlight and severe weather conditions. The rear of the instrument has IP20 protection. Cut-out dimensions Recommended for all installations. Mandatory to achieve IP66 seal between instrument and panel. 90 +0.5/-0.0 x 43.5 +0.5/-0.0 65 7.5 96 DISPLAY 48 Optional A1 A2 + Control output 1 A3 A4 + Control output 2 12 + Power supply 10 to 28V dc RS1 RS2 3 4 5 6 + Reset Add link Sensor to energise input sensor input Support panel wiring to prevent vibration damage Fig 1 Cut-out dimensions and terminals Abbreviated instructions for BA377E One input Intrinsically safe Timer or Clock BA377E HRS RTx MINS SECS Issue 4 24th November 2022 BEKA associates Ltd. Old Charlton Rd, Hitchin, Hertfordshire, SG5 2DA, UK Tel: +44(0)1462 438301 e-mail: sales@beka.co.uk web: www.beka.co.uk 1. Align foot and body of panel mounting clamp by turning screw anticlockwise 2. Position gasket behind instrument bezel 3. Insert instrument into the panel from the front 4. Insert panel clamp into recess and gently pull it onto the dovetail. Engage screw & turn clockwise to tighten the clamp, fit the other clamp(s). Recommended tightening torque 22cNm (1.95lbf.in) Equivalent to finger tight plus one half turn. DO NOT OVERTIGHTEN Fig 2 Installation procedure EMC For specified immunity all wiring should be in screened twisted pairs with screens earthed at one point within the safe area. Hazardous area Safe area DISPLAY RS2 RS1 6543 + 21 + + Sensor The input must be maintained not momentary Remote reset in hazardous area Sensor output Proximity detector Switch Contact Open collector Input Link 3 & 4 Voltage Don't link 3 & 4 Single channel positive polarity 28V: 93mA Zener barrier + Power supply Remote reset in safe area Single channel positive polarity 28V: 93mA Zener barrier Fig 3 Use with Zener barriers Scale card The Timer or Clock's units of measurement are shown on a printed scale card visible through a window at the right hand side of the display. The scale card is mounted on a flexible strip that is inserted into a slot at the rear of the instrument as shown below Unlock Insert Lock Fig 4 Inserting flexible strip carrying scale card into slot at the rear of Timer or Clock. Thus the scale card can easily be changed without removing the Timer or Clock from the panel or opening the instrument enclosure. New Timer or Clocks are supplied with a printed scale card showing the requested units of measurement, if this information is not supplied when the Timer or Clock is ordered a blank card will be fitted. A pack of self-adhesive scale cards printed with common units of measurement is available as an accessory from BEKA associates. Custom printed scale cards can also be supplied. To change a scale card, unclip the protruding end of the flexible strip by gently pushing it upwards and pulling it out of the enclosure. Peel the existing scale card from the flexible strip and replace it with a new printed card, which should be aligned as shown below. Do not fit a new scale card on top of an existing card. Align on these edges Scale card Align the self-adhesive printed scale card onto the flexible strip and insert the strip into the Timer or Clock as shown. Fig 5 Fitting scale card to flexible strip 3. OPERATION The Timer or Clock is controlled by four front panel push buttons. When configured as a Timer they have the following functions in the operating mode: ( + ) Access to configuration menu. & When local control is enabled starts the Timer * When local control is enabled stops the Timer. ) + * Shows the grand total (run time) in hours and tenths of an hour irrespective of Timer configuration. If buttons are held for longer than ten seconds the grand total may be reset to zero if the grand total reset sub-function clr gtot is enabled in the LoC r5Et configuration function. To reset the grand total to zero from the display mode press the ) + * buttons for ten seconds until CLr. no is displayed, using the & or * button change the display to CLr. YE5 and press ). & + * Resets the Timer to zero or to the set time 5Et t depending on whether the Timer is configured to timeup or time-down when the two buttons are operated simultaneously for more than three seconds. This is a configurable function. ( + * When enabled in the configuration menu, operating these two buttons simultaneously provides direct access to the set time 5Et t and allows adjustment when the timer is in the display mode. ( + & Shows in succession, firmware version number, instrument function elap5e and any output accessories that are fitted: - A Dual Control Outputs See full instruction manual for description of use when configured as a Clock Display mode DISPLAY ( ) ) code ( 0000 Security Code Enter code by pressing * or & & ( to move to next digit. Code 0000 allows direct access to the menu 4. CONFIGURATION Timer or Clocks are supplied configured as requested at time of ordering, if not specified default Timer configuration will be supplied but can easily be changed on-site. Fig 6 shows the location of each function within the Timer configuration menu with a brief summary of the function. Please refer to the full instruction manual for detailed configuration information, description of optional outputs and Clock configuration menu. Access to the configuration menu is obtained by pressing the ( and ) buttons simultaneously. If the Timer or Clock's security code is set to default 0000 the first parameter function will be displayed. If the instrument is protected by a security code, code will be displayed. The four digit code must be entered to gain access to the menu. Only included when optional Control Outputs are fitted () ) ) ) ) ) ) ) ) ) ) ) & function * & input * & di5p-2 * & 5tart5top * & unit5 * & 5et t * & cycle5 * & ac5et t * & up or dn * & p-fail * & loc r5et * & op1 () () ) () () () () ( () ) () () () ) ( elap5e inp.type * & debounce 5td local 12 : 00 : 00 00 : 00 : 00 enbl * & accd dn idle r5etenbl * & clr gtot () () () () () () () ) ) ) ) * & op2 * & clr gtot * & code * & r5et def * () () () () As op1 clr. no 0000 0000 () 0000 op.col default off 0000 off off 0000 Function Input * or & to select * or & to select Function of instrument elap5e Interval measurement cloc Time display Confirm selection by entering 5ure by pressing * or & and ( to move to next digit Input type op.col Open Collector volt5 l Voltage <1V >3V volt5 h Voltage <3V >10V coil 0 < >40mV pr.det Proximity detector contact Switch contact Debounce * or & to select level of debounce. default light heavy Lower Display cycle5 not enabled * or & to select display Start & stop timer * or & to select how timer is controlled 5td Set time 5et t off lower display disabled ___________ cycle5 enabled * or & to select display 5td Cycle No. & total cycle with status shown at start of each operation local Start & button Stop * button control 1 Start Input high (open) Stop Input low (closed) control 2 Start Input low (closed) Stop Input high (open) label Cycle No. & total cycle with status shown periodically off lower display disabled hours minutes seconds Units of display * or & to select 12 : 00 : 00 12:00 30 : 00 30 Set time * or & to adjust value and ( to move control to next digit Enable access to Set Time from display mode Security code for direct access to Set Time * or & to select on or off Enter code by pressing * or & and ( to move to next digit Code 0000 allows direct access Direction of count * or & to select up or dn ) ) ) & enbl * & cycl cnt * & r5t dela * () () () off 00 00 : 00 : 00 : 00 Enable cycle function * and & to toggle between on and off Cycle count * and & to adjust flashing digit and ( to move to next digit. Restart delay * and & to adjust flashing digit and ( to move to next digit. The BA377E is CE marked to show compliance with the European Explosive Atmospheres Directive 2014/34/EU and the European EMC Directive 2014/30/EU. It is also UKCA marked to show compliance with UK statutory requirements Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations UKSI 2016:1107 (as amended) and with the Electromagnetic Compatibility Regulations UKSI 2016:1091 (as amended). Sets number of cycles between 1 and 99 to be performed. Sets delay between cycles in the same units as 5et t 00 for continuous cycling Manuals, certificates and datasheets can be downloaded from http://www.beka.co.uk/ba377e Timer repeat cycle function Power fail * or & to select how timer functions when power is restored after failure Local total reset * or & to turn the local total reset function on or off Local grand total clear * or & to turn the local grand total reset function on or off idle Stopped, requires reset & start input pau5e Paused, requires start input continue Resumes timing When on is selected pressing * and & simultaneously for more than 3 seconds in the display mode resets the total display When on is selected pressing ) and * simultaneously for more than 10 seconds in the display mode resets the grand total Clear grand total Define Reset Security Code configuration to press Timer factory * or & to select ye5 to reset grand total to zero. Confirm instruction by Enter by pressing & or * and ( to move to next digit defaults Confirm instruction by entering 5ure. Press & or * entering 5ure. to adjust each Press digit and ( & or * to adjust each to move to next digit digit and ( to move to next digit ) ) ) ) & enbl * & op1 on * & op1 off * & op1 dela * () () () () off 5tart 5top 00000 Enable output 1 * and & to toggle between on and off Output on at Output off at Output on delay * and & * and & * and & to select to select to adjust required function required function flashing digit re5et run pau5e re5et run pau5e and ( to move to next digit delay done n re5et n run n pau5e delay done n re5et n run n pau5e Set delay in seconds before output 1 is energised. n delay n delay n done n done Select action Select action that energises that de-energises output 1 output 1 Fig 6 Timer Configuration menu Output 1 configuration