Instruction Manual for BITMAIN models including: T19 Pro Hyd, T19 Pro Hyd BTC Miner, BTC Miner, Miner

T19 Pro Hyd. Product Manual

Bitmain, AntMiner, T19, Pro, Hyd.

Avi Eliav


File Info : application/pdf, 3 Pages, 832.77KB

PDF preview unavailable. Download the PDF instead.

T19 Pro Hyd. Product Manual V1.3.5
T19 Pro Hyd.
Product Manual
Sep. 2024
BITMAIN TECHNOLOGIES INC. www.bitmain.com

1. Specification
Product Glance
Model Version Crypto algorithm/coins Typical Hashrate, TH/s(1-1) Power on wall @35(1-2), Watt(1-1) Power efficiency on wall@35(1-2), J/TH(1-1)

T19 Pro Hyd. Product Manual
Value
T19 Pro Hyd. k0-10
SHA256|BTC/BCH/BSV 246 5412 22.0

Detailed Characteristics

Value

Power supply

Phase Input voltage, Volt(2-1)

3 380~415

Input frequency range, Hz

50~60

Input max current, Amp

12

Hardware configuration

Network connection mode

RJ45 Ethernet 10/100M

Server size (Length*Width*Height, w/o package), mm

410*170*209

Server size (Length*Width*Height, with package), mm

570*316*430

Net weight, kg

12.8

Gross weight, kg

14.1

Environment requirements

Inlet coolant temperature, °C

20~50

Coolant flow, L/min Coolant pressure, bar

8.0~10.0 3.5

Working coolant(2-2)

Antifreeze/ Pure water/Deionized water

Coolant pH value

Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water8.5~9.5

Diameter of coolant pipe connector, mm

OD10

Storage temperature, °C

-20~70

Operation humidity(non-condensing), RH

10~90%

Notes:

(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%. (1-2) Inlet coolant temperature. (2-1) Caution: Wrong input voltage may cause server damaged. (2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!

-2-

2. Performance Curve
(1) Hashrate vs. Inlet Coolant Temperature

T19 Pro Hyd. Product Manual

Hashrate (TH/s)

300

246

246

T19 Pro Hyd. Hashrate(3-1)

246

246

246

246

246

200 Water&Antifreeze
100

0

20

25

30

35

40

45

50

Inlet Coolant Temperature ()

(2) Power Efficiency vs. Inlet Coolant Temperature

Power Efficiency (J/T) 30

T19 Pro Hyd. Power Efficiency(3-1)

25 22

22

22

22

22.6

20

15

10

5

0

20

25

30

35

40

Inlet Coolant Temperature ()

23.4

24.3

Water&Antifreeze

45

50

(3-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

-3-



References