Installation Guide for LG models including: KUSAB181A, KNUAK181A, KSUAK181A Art Cool Mirror Wall Mounted, KSUAK181A, Art Cool Mirror Wall Mounted, Cool Mirror Wall Mounted, Mirror Wall Mounted, Wall Mounted
LG KSUAK181A Art Cool Mirror Ductless Mini Split Heat Pump System - Single-Zone - 18k BTU - 23.0 SEER2 - R-32
File Info : application/pdf, 3 Pages, 6.29MB
DocumentDocumentJob Name/Location: Date: PO No.: Architect: Engr: Rep: (Company) For: File Resubmit Approval Other GC: Mech: (Project Manager) Tag No.: KSUAK181A R32 Single Zone Art CoolTMM irror Wall M ount ed Out door Unit (ODU) - KUSAB181A, Indoor Unit (IDU) - KNUAK181A Performance: Cooling: Cooling Capacity (Min~Rated~Max, Btu/h) SEER2 EER2 3,070 ~ 18,000 ~ 24,210 23.0 13.00 SEER - Seasonal Energy Efficiency Ratio Heating: EER - Energy Efficiency Ratio Heating Capacity (Min~Rated~Max, Btu/h) HSPF2 Max. Heating @ Indoor 70°F DB (Btu/h) Outdoor 17°F WB Outdoor 5°F WB Outdoor -4°F WB 3,070 ~ 21,600 ~ 30,020 10.0 18,600 (86%) 15,120 (70%) 12,160 (56%) HSPF - Heating Seasonal Performance Factor Cooling Nominal Test Conditions: Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB Electrical: Heating Nominal Test Conditions: Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB Power Supply (V¹/Hz/Ø) MOP (A) MCA (A) 208-230 / 60 / 1 30 19 Cooling / Heating Rated Amps (A) 15.1 Compressor (A) 14.3 Fan Motor (IDU + ODU) (A) 0.4 + 0.78 Cooling Power Input (Min~Rated~Max, kW) 0.30 ~ 1.38 ~ 2.65 Heating Power Input (Min~Rated~Max, kW) 0.66 ~ 1.83 ~ 3.30 Locked Rotor Amps (A) 17.0 MOP - Maximum Overcurrent Protection Piping: MCA - Minimum Circuit Ampacity Installed Liquid Pipe (in., O.D.) Installed Vapor Pipe (in., O.D.) IDU Liquid Connection (in., O.D.) IDU Vapor Connection (in., O.D.) Additional Refrigerant (oz./ft.) Min. / Max. Pipe Length (ft.)² Piping Length (no add'l refrig., ft.) Max. Elevation (ft.) 3/ 8 Flare 5/ 8 Flare 3/ 8 Flare 5/ 8 Flare 0.32 9.8 / 114.8 24.6 49.2 Features: · Inverter (Variable Speed Compressor) · 24-Hour on/off timer · 4-Way auto swing · Sleep Mode · Jet Cool/Jet Heat · Auto Restart · Auto Changeover · Built-in Drain pan heater · Built-in Wi-Fi via ThinQ app · Smart Diagnosis · 3M Micro Filter · IDU compatible with Multi F ODUs · Low ambient cooling down to 14°F (0°F with Wind Baffle Kit) · Self-cleaning indoor coil · IDU R32 leak detection sensor Included Accessories: · Wireless Remote Controller -- AKB76044208 Operating Range: Outdoor Unit: Cooling (°F DB) Heating (°F WB) Indoor Unit: 14 ~ 118 -4 ~ +65 Cooling (°F WB) Heating (°F DB) System Data: Refrigerant Type Refrigerant Control Refrigerant Charge (lbs.) ODU Sound Pressure (Cooling / Heating) (±1 dB[A])3 IDU Sound Pressure Cooling (H/M/L/SL) (±1 dB[A])3 Heating (H/M/L) (±1 dB[A])³ ODU Net / Shipping Weight (lbs.) IDU Net / Shipping Weight (lbs.) Heat Exchanger Coating Fan: 53 ~ 75 60 ~ 86 R32 EEV 3.20 55 / 55 47 / 42 / 37 / 31 47 / 42 / 37 127.9 / 145.5 27.8 / 33.5 GoldFinTM ODU Type IDU Type Fan Speeds (Fan/Cool/Heat) Quantity (ODU + IDU) Motor/Drive Propeller Cross Flow 6 / 6 / 6 1 + 1 Brushless Digitally Controlled / Direct Maximum ODU Air Volume (CFM) 2,119 IDU Air Flow Cooling, Max/H/M/L (CFM) 706 / 530 / 477 / 371 Heating, Max/H/M/L (CFM) 706 / 547 / 494 / 371 Dehumidification (pts./hr.) 5.5 Notes: 1. Acceptable operating voltage: 187V-253V. 2. Piping lengths are equivalent. 3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745. 4. All power supply wiring to the outdoor unit is field supplied, solid or stranded. The power wiring and the communication wiring from the outdoor unit to the indoor unit is field supplied and must be stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only). All wiring must comply with applicable local and national codes. a. Power Supply Wiring to ODU: (No. x AWG): 3 x 14 for 9/12k, 3 x 12 for 18k units. b. Power Wiring / Communication Wiring from Outdoor Unit to Indoor Unit: (No. x AWG) 3 x 14 / 2 x 18. 5. See Engineering Manual for sensible and latent capacities. 6. Power wiring cable size must comply with the applicable local and national code. 7. The indoor unit comes with a dry helium charge. 8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units. 9. Must follow installation instructions in the applicable LG installation manual. 10. Multi-compatible 18k IDUs include socket adapters for refrigerant pipe connections with single zone systems. BACnet® is a registered trademark of ASHRAE. LonWorks® is a trademark of Echelon Corporation. Optional Accessories: PI-485 - PMNFP14A1 Single-Port Shutoff Valve - PRHPZ010A Low Ambient Wind Baffle (Cooling to 0°F) - ZLABGP04A Controller Options: MultiSITETM CRC* Controllers Simple Remote Controllers Standard III Remote Controllers Remote Temp. Button Sensor Dry Contacts AC Smart 5 Central Controller LonWorks® Gateway MultiSITE Comm. Mgr. AC Smart BACnet® Gateway Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar. gov. (ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.) For a complete list of available accessories, contact your LG representative. For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com SB_SZ_Art _Cool_M irror_R32_KSUAK181A_2024_12_18_161938 Page 1 of 3 Job Name/Location: KSUAK181A R32 Single Zone Art CoolTMM irror Wall M ount ed Out door Unit (ODU) - KUSAB181A, Indoor Unit (IDU) - KNUAK181A Tag No.: Date: PO No.: For continual product development, LG reserves the right to change specifications without notice. SB_SZ_Art _Cool_M irror_R32_KSUAK181A_2024_12_18_161938 © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 3 Job Name/Location: KSUAK181A R32 Single Zone Art CoolTMM irror Wall M ount ed Out door Unit (ODU) - KUSAB181A, Indoor Unit (IDU) - KNUAK181A Tag No.: Date: PO No.: For continual product development, LG reserves the right to change specifications without notice. SB_SZ_Art _Cool_M irror_R32_KSUAK181A_2024_12_18_161938 © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com Page 3 of 3