User Guide for LIGHTOLIER models including: C6RA LED 6 Gen 3 Round AirSeal IC Frame, C6RA LED 6, Gen 3 Round AirSeal IC Frame, AirSeal IC Frame, IC Frame, Frame

Downlighting

24 oct. 2021 — Universal 120-347V for 0-10v (Z10) dimming only. Non-Z10 dimming options available for 120/277V only. 2. Consult factory for 5000K CCT (50) with narrow (N) ...


File Info : application/pdf, 10 Pages, 1.80MB

PDF preview unavailable. Download the PDF instead.

Calculite-LED-6in-Airseal-C6R---Spec-Sheet
Downlighting
Calculite LED 6" gen 3
C6RA Round AirSeal IC frame
Calculite LED 4" generation 3 provides excellent performance coupled with optimized installation flexibility via UniFrame. Industry leading visual comfort and uniform illumination make it an ideal choice for open office, institution, healthcare, and retail applications.
Complete luminaire = Frame + Engine + Trim + Accessories (optional)

Project: Location: Cat.No: Type: Qty: Notes:

Frame
Series
6
6 6" New Construction

Aperture
R
R Round

example: 6RA Installation
A
A AirSeal IC 120/277/347V 1

Engine

example: C4L15835NZ10U

Series
C6L

Lumens

CRI/CCT

Beam

Dimming

Options

Voltage

C6L Calculite LED 6" gen 3

10 1000 lm 15 1500 lm 20 2000 lm 25 2500 lm 30 3000 lm

927 90CRI/2700K 930 90CRI/3000K 935 90CRI/3500K 940 90CRI/4000K 950 90CRI/5000K 2 D2W 90CRI/3000K
to 1800K 3 (dim-to-warm)

N Narrow (43°) 2 M Medium (56°) 2 W Wide (76°) 4

Z10 0-10 V 1%

---- None D2O Dim to Off

L01 Lutron PEQ0 EcoSystem 0.1% (up to 2000lm) L1 Lutron LDE1 EcoSystem 1%

D DALI 0.1%

---- None LIN Linear

SOL EldoLED Solo 0-10 V 0.1% DMX Digital Multiplexing w/RDM 0.1%

---- None LIN Linear SQR Square

E Forward & Reverse Phase (up to 3000lm) LTE Lutron LTE Hi-Lume Phase Cut 1%

P Power over Ethernet (PoE) only compatible with 1000 (10) to 2500 (25) lumen configs

U 120/277V 3 347V (Z10 only) U 120/277V U 120/277V U 120/277V
1 120 V E Ethernet 48V DC

Trim

Series

Aperture

C6

R

C6L Calculite LED 6" gen 3

R Round

Style
DL Downlight WW Open Wall Wash4 LW Lensed Wall Wash4 CW Corner Wall Wash4,5 DW Double Wall Wash4,5

Finish

example: C6RDLNMCCP Flange

CL Specular clear CC Comfort clear CD Comfort clear diffuse CZ Champagne bronze BK Black (anodized)
WH White (matte) WHAMF White (gloss antimicrobial)

­ White (matte) P Polished (matches aperture) F Flangeless (requires CA6RFT)
­ White (matches finish) F Flangeless (requires CA6RFT)

Accessories

SBA 7920 CA6RFT

Interact Ready System Bridge Accessory with integral occupancy and daylight sensor (compatible with all 0-10V options, see SBA spec sheet) 6 4" sloped ceiling adapter (refer to SCA spec sheet for slope options) Mud-in ring for use with flangeless installations (ordered with a flangeless trim)

1. Universal 120-347V for 0-10v (Z10) dimming only. Non-Z10 dimming options available for 120/277V only. 2. Consult factory for 5000K CCT (50) with narrow (N) beam. 3. Dim-to-warm (D2W) available only with Z10 dimming. Narrow (N) and medium (M) beams only. 4. Wide (W) beam is ideal for all Wall Wash (LW, WW, CW, DW) applications. 5. Corner (CW) and Double (DW) Wall Wash are not available with flangeless (F) option. 6. Requires IRT9015 IR remote & Interact Pro App for commissioning.

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 1 of 10

WET LOCATION

IC
INSULATION
CONTACT

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

Frame-in-kits
AirSeal: Galvanized steel housing for dry or plaster ceilings. Pre-installed telescoping mounting bars from 13" to 24".
Patented install Mounting frame: With no driver attached, this versatile frame is independent of driver accommodating a wide range of lumen packages, driver types and CCTs, including 120V and 277V inputs.
Close-cut aperture design eliminates possibility of gap between ceiling opening & reflector flange.
Separate wiring compartment for wiring frame to building allows inspection prior to light engine install.
Simple plug-and-play connection between frame and light engine from below ceiling eliminates need for wiring between frame and LED driver, and also saves time during installation and future replacements/upgrades. Plug-and-play receptacle accommodates technology upgrade of light engines and replacements for the life of the building.
Dimming
All configurations are FCC Class A unless otherwise specified. · Advance 0-10V 1% (Z10), logarithmic curve is
standard, specify D2O for factory-set dim-to-off function, consult factory for linear dimming curve. · EldoLED SOLODrive (SOL) 0-10V 0.1% · Lutron PEQ0 (L01) Hi-Lume Premier EcoSystem 0.1% · Lutron LDE1 (L1) EcoSystem 1% · Lutron LTE (LTE) Hi-Lume 2-wire phase cut 1% · Electronic low voltage (E) - forward or reverse phase dimming, remodel and AirSeal IC Shallow are FCC Class B · DALI (D) - DT6 DALI 0.1% · DMX (DMX) - Digital multiplexing with RDM 0.1% · Dim to Warm (D2W): option changes CCT from 3000-1800K gradually as it dims. Use with Z10 dimming only. Fixture-to-fixture consistency of 3SDCM at 2700K & 3000K, and 5SDCM at 1800K. Dimming options: The following are factory-set for the SOL, D, and DMX driver options (ex. DMXLIN): · SOL/D/DMX: Logarithmic (-) standard · SOL/D/DMX: Linear (LIN) · SOL/DMX: Square (SQR)

Optical systems
Comfort throughout the space: Patented optical system combines primary and secondary optics to provide a true 50° physical cutoff and 45° reflected cutoff virtually eliminating the view of the light source and bright spots in the reflector. A new reflector curve reduces reflector brightness by up to 50% compared to existing products, allowing for the use of higher lumen packages in smaller apertures without creating bright spots in the ceiling.
MesoOptics PET optical diffusion film: provides a smooth beam shape and mitigates color over angle with optimized luminaire efficiency.
Quality of light: 2 SDCM ensures color consistency from fixture to fixture and over the luminaire's long lifetime. Proprietary optical grade silicone lens with patterned surface provides soft, even beam diffusion without hotspots or dark rings.
Light Engine
Quick connect power pack comprised of light source and driver allow for easy installation and replacement from below ceiling with no need for additional wiring. This allows for:
- Frame and ceiling installation to be performed while still finalizing details such as lumen packages, CCT and control type.
- Easy replacement of electronics at end of life with minimal wasted material and labor required.
- Ease and upgradability of technology.
- 347V light engines are 0-10v dimming only and include dedicated 347V driver for use with universal 120/277/347V (U) frames. All other dimming options available only for 120/277V input.

Options and Accessories
Flangeless mud-in ring: Use CA6RFT For use with flangless plaster installations.
Sloped ceilings: Compatible with sloped ceiling adapters (see SCA spec sheet).
C6RVPWH: Includes machined aluminum ring painted white, gasketed for IP65 protection, and impact resistant polycarbonate lens (IK10). Locks in place with discrete setscrew (key included). Available also with antimicrobial fiinsh (C6RVPWHAMF).
SBA: Interact Ready System Bridge Accessory. Requires IRT9015 IR remote and Interact Pro App for commissioning. Specify with integral occupancy and daylight sensing capabilities for controls and compatibility with Interact Pro.
ENERGY STAR® exceptions
- 90 CRI & all Wall wash configurations - Champagne Bronze and Black finishes - Dali, ELV & EldoLED Solo drivers
Title 24 exceptions
- 1000 lm in Downlight, Wall Wash & Lensed Wall Wash configurations
- Champagne Bronze and Black finishes
Labels and Listings
- cULus listed for wet locations - ENERGY STAR® certified - RoHS certified - CEC Title 24 JA8 certified
Warranty
5 year limited warranty Visit Signify.com/warranties for more information on Signify's standard 5- year limited warranty on complete luminaire systems.

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 2 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

Reflector

Flanges

Specular clear (CL): Most specular and most efficient finish, delivers maximum photometric performance but can produce a mirror image effect of the interior space.

Champagne bronze (CZ): Semi-specular finish that softens light at the source of the reflector while providing a warmer reflector appearance (slightly warmer).

White (­): (matte) Provides the smoothest transition to ceilings when off.

Comfort clear (CC): Semi-specular finish that softens the light at the source of the reflector and creates a subtle, even luminance from the reflector cone.

White (WH): (matte) Brightest illuminated aperture and provides the smoothest transition to most ceilings when off (white is only available with a white flange).

Polished (P): (matches aperture) Produces a continuous look throughout the reflector (aperture matching).

Comfort clear diffuse (CD): Slightly diffuse clear finish, that eliminates iridescence and reduces the mirror image effect inherent with specular finishes.

Black (BK): (anodized) Specular finish that provides the lowest aperture brightness possible and significantly reduces source identification in a ceiling.

Flangeless (F): (flush-mount)Creates a flush, virtually seamless transition from aperture to ceiling.

Mud-in ring (FT): Low profile, machined aluminum mud-in ring provides a raised rib to plaster up to and a 3/16" flange thickness. The ring is attached to the ceiling material as opposed to the frame-in kit to avoid conduction of heat and vibration which can cause yellowing or cracking of the plaster.

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 3 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

AirSeal (A)

13 1/4 in 337 mm
10 in 254 mm

Flangeless mud-in ring (CA6RFT) accessory

D
81/2 in 216 mm

63/8 in 163 mm
61/2 in 165 mm

Detail D

19 5/8 in 498 mm
14 1/2 in 368 mm

7 1/4 in 184 mm

13 1/4 in 337 mm

7 1/4 in 184 mm
19 5/8 in 498 mm

Electrical - Narrow

Light engine 1000lm
1500lm
2000lm
2500lm
3000lm

Input Volts 120V 277V 347V 120V 277V 347V 120V 277V 347V 120V 277V 347V 120V 277V 347V

Input Freq. 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz

THD Power Input Drive Input LED Factor Factor Current Current Power Power @ Max Load 0.072A 0.22A 8.6W 7.0W <10% >0.9 0.032A 0.22A 8.8W 7.0W <20% >0.9 0.029A 0.22A 10.0W 7.0W <30% >0.9 0.107A 0.33A 12.8W 10.7W <10% >0.9 0.046A 0.33A 12.9W 10.7W <10% >0.9 0.042A 0.33A 14.6W 10.7W <25% >0.9 0.145A 0.45A 17.4W 14.7W <10% >0.9 0.063A 0.45A 17.5W 14.7W <10% >0.9 0.056A 0.45A 19.4W 14.7W <20% >0.9 0.178A 0.55A 21.4W 18.2W <10% >0.9 0.078A 0.55A 21.5W 18.2W <10% >0.9 0.065A 0.55A 22.7W 18.2W <20% >0.9 0.212A 0.65A 25.5W 21.7W <10% >0.9 0.091A 0.65A 25.3W 21.7W <10% >0.9 0.077A 0.65A 26.7W 21.7W <15% >0.9

Electrical - Medium & Wide

Light engine 1000lm
1500lm
2000lm
2500lm
3000lm

Input Volts 120V 277V 347V 120V 277V 347V 120V 277V 347V 120V 277V 347V 120V 277V 347V

Input Freq. 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz

THD Power Input Drive Input LED Factor Factor Current Current Power Power @ Max Load 0.073A 0.22A 8.7W 7.1W <10% >0.9 0.032A 0.22A 8.9W 7.1W <20% >0.9 0.029A 0.22A 10.2W 7.1W <30% >0.9 0.109A 0.33A 13.0W 10.9W <10% >0.9 0.047A 0.33A 13.1W 10.9W <10% >0.9 0.043A 0.33A 14.9W 10.9W <25% >0.9 0.149A 0.45A 17.8W 15.1W <10% >0.9 0.065A 0.45A 18.0W 15.1W <10% >0.9 0.057A 0.45A 19.8W 15.1W <20% >0.9 0.179A 0.55A 21.4W 18.2W <10% >0.9 0.078A 0.55A 21.6W 18.2W <10% >0.9 0.066A 0.55A 22.8W 18.2W <20% >0.9 0.220A 0.67A 26.4W 22.4W <10% >0.9 0.095A 0.67A 26.2W 22.4W <10% >0.9 0.079A 0.67A 27.5W 22.4W <15% >0.9

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 4 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

Lifetime (TM-21) data

Lumens
1000lm 1500lm 2000lm 2500lm
3000lm

Narrow beam L85 @ 55,000hrs. L85 @ 55,000hrs.

Medium/Wide beam L85 @ 60,000hrs. L80 @ 60,000hrs.

CCT (K)

Dim-to-Warm: CCT vs Dimmed level

3200

3000

2800

2600

2400

2200

2000

1800

1600

2% 15% 30% 50% 75% 100%
Dimming level

AccuRender Technology (CRI 90+)
The right light brings colors to life. Our new AccuRender technology helps ensure colors are rendered more accurately and consistently, while doing so as efficiently as CRI 80 products.

Standard CRI 80
Good color rendering and high efficacy

Standard CRI 90
Better color rendering and low efficacy

AccuRender
Best color rendering, color preference and high efficacy

Enjoy design flexibility
Full range of products and options:
· Available soon in across Lightolier portfolio for application flexibility
· Multiple color temperatures (CCTs) and lumen packages offered

Promote savings
High efficacy, with no penalty: · Energy efficacy compares
well to conventional 80 CRI · Up to 25% more energy
savings vs competitor 90 CRI 1 · Helps meet Title 24 requirements

Show your true colors

Achieve color balance

High color rendering:

Best in class color consistency:

· True to life colors that help energize your environment and render better flesh tones critical for healthcare hospitality and retail applications.

· Promote aesthetic harmony in your space with  2 SDCM

· Ra up to 94 CRI · Rf up to 92 TM-30 R9 up to 67 CRI Rf,h1 up to 91 TM-30 Ga up to 99 CRI R9 up to 100 TM-30 C9 up to 94 CRI Rcs,h1 up to -5% TM-30

Round Downlight

Photometric - Downlights with CRI of 90+ & R9 of 50+

Lumen Package Beam

Flux Efficacy Beam

IES TM-30-18

(lm) (lm/W) Angle CBCP CRI R9 Rf Rg Rcs,h1 UGR

1000 lm Narrow (N) 989 115 36° 2510 90+ 50+ 91 100 -5% 0

Medium (M) 1011 116 57° 1183 90+ 50+ 91 100 -5% 0

Wide (W)

942 108 76° 641 90+ 50+ 91 100 -5% 0

1500 lm Narrow (N) 1522 119 36° 3863 90+ 50+ 91 100 -5% 1

Medium (M) 1530 117 57° 1790 90+ 50+ 91 100 -5% 1

Wide (W)

1420 109 76° 965 90+ 50+ 91 100 -5% 1

2000 lm Narrow (N) 2075 119 36° 5265 90+ 50+ 91 100 -5% 2

Medium (M) 2070 116 57° 2422 90+ 50+ 91 100 -5% 2

Wide (W)

1918 107 76° 1304 90+ 50+ 91 100 -5% 2

2500 lm Narrow (N) 2511 115 36° 6372 90+ 50+ 91 100 -5% 3

Medium (M) 2526 119 57° 2954 90+ 50+ 91 100 -5% 3

Wide (W)

2377 112 76° 1616 90+ 50+ 91 100 -5% 3

3000 lm Narrow (N) 2927 115 36° 7428 90+ 50+ 91 100 -5% 4

Medium (M) 3051 116 57° 3568 90+ 50+ 91 100 -5% 4

Wide (W)

2834 107 76° 1926 90+ 50+ 91 100 -5% 4

Round Wall Wash

Photometric - Downlights with CRI of 90+ & R9 of 50+

Lumen Package Beam

Flux Efficacy Beam

IES TM-30-18

(lm) (lm/W) Angle CBCP CRI R9 Rf Rg Rcs,h1 UGR

1000 lm Open (WW) 787 90

--

-- 90+ 50+ 93 100 -3% 9

Lensed (LW) 725 83

--

-- 90+ 50+ 91 100 -6% 15

1500 lm Open (WW) 1186 91

--

-- 90+ 50+ 93 100 -3% 10

Lensed (LW) 1093 84

--

-- 90+ 50+ 91 100 -6% 17

2000 lm Open (WW) 1602 90

--

-- 90+ 50+ 93 100 -3% 11

Lensed (LW) 1476 83

--

-- 90+ 50+ 91 100 -6% 18

2500 lm Open (WW) 1986 91

--

-- 90+ 50+ 93 100 -3% 12

Lensed (LW) 1830 84

--

-- 90+ 50+ 91 100 -6% 19

3000 lm Open (WW) 2367 90

--

-- 90+ 50+ 93 100 -3% 13

Lensed (LW) 2181 83

--

-- 90+ 50+ 91 100 -6% 19

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 5 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

Dimming, grouping, and zoning Bluetooth and ZigBee enabled Motion sensing and daylight harvesting Integration with 0-10V and phase dimming fixtures Code compliance Granular dimming and dwell time Correlated color temperature (CCT) tuning by switch Support for sensor-based Tunable White luminaires Energy reporting and monitoring Scheduling Demand response BMS integration (BACnet) Floor plan visualization IoT sensors for wellness IoT Apps for productivity

Standalone
New New

Option 1

Gateway Connected Option 2

Currently supported maximum system size
To be able to design the lighting system correctly for the customer, it is important to know the prime characteristics of the system, its possibilities and limitations.

System level Total number of gateways Total number of devices · Luminaires with integrated sensors · Smart TLEDS · Zones + groups Total number of ZGP devices (sensors and switches) · Sensors · Switches

Unlimited 200 per network 150 150 64
50
30 50

Group level Recommended number of lights Number of ZGP devices Number of scenes

40 (maximum 150) 5 16

Interact IOT platform

Wireless gateway

IT infrastructure

Wireless gateway

Interact Pro app

Wireless switch relay controller (plug load, relay, dimming)

Luminaires with wireless 0-10V control Phase dimming

integrated sensor

module

module

Wireless repeater and controller for exterior applicatons

Commissioning remote

Wireless wall switch

External battery Smart powered sensor LED lamp

Site & area luminaire with
sensor

Parking garage luminaire with
sensor

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 6 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

Wireless controls options

Interact

Radio only sensor (RA or RADIO)

Sensor bundle (IAOSB or SB)

· SWZCS is a connected sensor with integral occupancy and daylight sensing and supports wireless mesh connectivity.

· Integral RA or RADIO only sensor simply enables wireless mesh connectivity to the luminaire without any occupancy or daylight sensing.

· A wireless IoT connected lighting solution for large enterprises that span across multiple floors, buildings and require multiple gateways.

· The sensor works in the standalone mode (similar to SpaceWise) when configured without a gateway or in a cloud connected mode if a compatible gateway is used.
· Interact includes an App, a portal and a broad portfolio of wireless luminaires, lamps and retrofit kits all working on the same system.
· Startup is implemented via Interact Pro App (Android or iPhone) & BlueTooth connectivity. The App provides flexibility to choose between a gateway or non gateway mode for setup.
· Setup with the gateway requires wired internet access to the gateway. It is possible to add a gateway at a later point.
· Prepare project configuration steps remotely and use IRT9015 remote on-site to identify and group devices together.
Compatible with:
- SWS200 & UID8465 wireless scene switch
- Battery powered IP42 presence sensor OCC sensor IA CM WH 10/1
- Battery powered IP42 presence & daylight sensor OCC-DL sensor IA CM IP42 WH
- LCN3110: battery powered IP65 presence sensor, OCC sensor IA CM IP65W
- LCN3120: battery powered IP65 presence & daylight sensor, OCC-DL sensor IA CM IP65 WH
· For more information on Interact visit: interact-lighting.com/interactproscalablesystem

· Ideal for applications where sensing functionality is managed by other Interact devices and the luminaire only needs to have wireless connectivity.
· Interact includes an App, a portal and a broad portfolio of wireless luminaires, lamps and retrofit kits all working on the same system.
· Startup is implemented via Interact Pro App (Android or iPhone) & Bluetooth connectivity. The App provides flexibility to choose between a gateway or non-gateway mode for setup.
· Setup with the gateway requires wired internet access to the gateway. It is possible to add a gateway at a later point.
· Prepare project configuration steps remotely, identify and group devices together onsite.
· Compatible with SWS200 and UID8465 wireless scene switch, wireless Occ sensor (OCC SENSOR IA CM IP42 WH 10/1) and wireless Day/Occ sensor (OCC MULTI SENSOR IA CM WH 10/1).
· For more information on Interact visit: interact-lighting.com/interactproscalablesystem

· View all your projects under one dashboard and easily compare insights from multiple projects in one view.
· Compatible with SWS200 wireless scene switch, wireless Occ sensor (OCC SENSORIA CM IP42 WH 10/1) and wireless Day/Occ sensor (OCC MULTI SENSOR IA CM WH 10/1) and wireless Occupancy or Daylight & Occupancy sensors available.· Use Interact software and insights to increase building efficiency, achieve building wide integration and optimize space through occupancy analytics.
· IAOSB or SB option in addition to occupancy and daylights sensing supports advanced IoT capabilities, such as people estimation analysis, desk level temperature & humidity sensing, noise classification, and BLE beacon.
· Requires compatible Gateway and internet connectivity for commissioning.
· For more information, visit: interact-lighting.com/interactproscalablesystem
Emergency Options (ER100)
· Power Sensing (factory default) ­ Recommended UL924 option requires unswitched power sense line, absence of voltage on the normal circuit triggers luminaire to 100% output.
· Power Interruption Detection (field option) ­ Detects AC power interruption >30ms triggers 90 minute emergency mode with luminaire at 100% output.

Wired controls options

Interact (PoE):

· PoE based IoT connected lighting solution for large enterprises that span across multiple floors, buildings and require multiple gateways.
· Use Interact software and insights to increase building efficiency, achieve building wide integration and optimize space through occupancy analytics.

· Supports advanced IoT Apps on Personal Control, Space Management, wayfinding, room/desk reservation and offers open APIs for light control and data exchange.
· Integral sensor option for occupancy sensing (PIR) and/or daylight harvesting available for additional energy savings.

· Test switch and indicator light mounted on side of chassis on one end.

· Optional integral emergency controller and battery pack provides 600lm nominal output.

· PoE lighting controller is accessible from below.
· Emergency battery has a 3 month pre-installed shelf life, and must be stored and installed in environments of 20C to 30C (-4F to 86F) ambient, and 45-85% relative humidity.
· For more information on Interact Office Wired, visit: interact-lighting.com/office or www.usa.lighting.philips.com/systems/systemareas/offices.

Interact supported sensor option codes across Genlyte product lines

ZigBee + Bluetooth + Sensing ZigBee + Bluetooth ZigBee + Bluetooth + Sensing + Environmental data ZigBee + Highbay + Sensing

Evokit SWZCS RADIO IAOSB
-

Day-Brite SWZCS RADIO IAOSB SWZCSH

Ledalite CS RA SB -

Lightolier SBA accessory (external)
RA SB -

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 7 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

Narrow beam, 2500lm Engine, 115 lm/W at 22W

Candela Curve

1625 3250 4875 6500

6RA / C6L25935NZ10U / C6RDLCL

Output lumens: Input watts: CRI: CCT 1: Spacing Crit.: Beam Angle:

2512 lms 21.8 W 90 min 3500K 0.6 36°

Zonal summary

Zone Lumens %Luminaire

0-30 0-40 0-60 0-90

2231 2423 2510 2512

88.8% 96.5% 99.9% 100.0%

Angle Mean CP Lumens

0

6372

5 6006

10

4997

540

15

3915

20 2643 1066

25

1335

30

514

625

35

286

40

222

192

45

107

50

12

83

55

4

60

2

4

65

1

70

1

1

75

1

80

0

0

85

0

90

0

0

Single unit data

Height to Initial center beam

Beam

lighted plane foot-candles diameter (ft)*

8'

100

4.8'

9'

79

5.4'

10'

64

6.0'

12'

44

6.6'

14'

33

8.4'

* Beam diameter is where foot-candles drop to 50% of maximum.

Multiple unit data - RCR 2

Spacing Initial center beam

Watts

on center

foot-candles

per sq. ft.

5'

118.0

0.97

6'

77.0

0.63

7'

55.0

0.45

8'

46.0

0.38

9'

37.0

0.30

38' x 38' x 10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances

Efficacy: 115.2 lm/W Report2: STMR-1590.2

Adjustment factors

Finish

CCT

CL = 100% CC = 95% CD = 87% CZ = 63% WH = 87% BK = 57%

90CRI, 4000K = 102% 90CRI, 3500K = 100% 90CRI, 3000K = 96% 90CRI, 2700K = 92%

Lumens
3000lm = 120% 2500lm = 100% 2000lm = 80% 1500lm = 60% 1000lm = 40%

Coefficients of utilization

Ceiling

80%

70%

50%

30% 0%

Wall 70 50 30 10 50 10 50 10 50 10 0

RCR Zonal cavity method - Effective floor reflectance = 20%

Room Cavity Ratio

0 119 119 119 119 116 116 111 111 106 106 100 1 114 112 110 108 110 106 106 103 102 100 95 2 110 106 102 100 104 99 101 96 98 94 91 3 106 100 96 93 99 92 96 91 94 89 87 4 102 95 91 87 94 87 92 86 90 85 83 5 98 91 86 83 90 82 88 82 87 81 79 6 94 87 82 78 86 78 85 78 83 77 75 7 91 83 78 75 82 75 81 74 80 74 72 8 87 80 75 71 79 71 78 71 77 71 69 9 84 76 72 68 76 68 75 68 74 68 67 10 81 74 69 66 73 66 72 65 72 65 64

Medium beam, 2500lm Engine, 119 lm/W at 21W

Candela Curve

750 1500 2250 3000

6RA / C6L25935MZ10U / C6RDLCL

Output lumens: Input watts: CRI: CCT 1: Spacing Crit.: Beam Angle:

2527 lms 21.3 W 90 min 3500K 0.96 56°

Zonal summary

Zone Lumens %Luminaire

0-30 0-40 0-60 0-90

1994 2410 2524 2527

78.9% 95.4% 99.9% 100.0%

Angle Mean CP Lumens

0 2954

5 2968

10 2965

283

15 2929

20 2620

811

25 2022

30

1240

900

35

628

40

322

416

45

137

50

15

110

55

4

60

2

4

65

1

70

1

1

75

0

80

0

0

85

0

90

0

0

Single unit data

Height to Initial center beam

Beam

lighted plane foot-candles diameter (ft)*

5'

118

4.8'

6'

82

5.8'

7'

60

6.7'

8'

46

7.7'

9'

36

8.6'

* Beam diameter is where foot-candles drop to 50% of maximum.

Multiple unit data - RCR 2

Spacing Initial center beam

Watts

on center

foot-candles

per sq. ft.

5'

116.0

0.94

6'

76.0

0.62

7'

54.0

0.44

8'

45.0

0.37

9'

36.0

0.30

38' x 38' x 10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances

Efficacy: 118.6 lm/W Report2: STMR-2437

Adjustment factors

Finish

CCT

CL = 100% CC = 95% CD = 87% CZ = 63% WH = 87% BK = 57%

90CRI, 4000K = 102% 90CRI, 3500K = 100% 90CRI, 3000K = 96% 90CRI, 2700K = 92%

Lumens
3000lm = 120% 2500lm = 100% 2000lm = 80% 1500lm = 60% 1000lm = 40%

Coefficients of utilization

Ceiling

80%

70%

50%

30% 0%

Wall 70 50 30 10 50 10 50 10 50 10 0

Room Cavity Ratio

RCR
0 1 2 3 4 5 6 7 8 9 10

Zonal cavity method - Effective floor reflectance = 20%
119 119 119 119 116 116 111 111 106 106 100 114 111 109 107 109 105 105 102 101 99 94 109 104 100 97 102 96 99 94 96 92 88 103 97 93 89 96 88 93 87 91 85 83 99 91 86 82 90 82 88 81 86 80 77 94 86 81 76 85 76 83 75 82 75 73 90 81 75 71 80 71 79 71 77 70 68 85 77 71 67 76 67 75 66 73 66 64 81 72 67 63 72 63 71 62 70 62 61 78 69 63 59 68 59 67 59 66 59 57 74 65 60 56 65 56 64 56 63 56 54

1. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products.

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 8 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

Wide beam, 2500lm Engine, 112 lm/W at 21W

Candela Curve

450 900 1350 1800

4RA / C6L25935WZ10U / C6RDLCL

Output lumens: Input watts: CRI: CCT 1: Spacing Crit.: Beam Angle:

2378 lms 21.3 W 90 min 3500K 1.3 76°

Zonal summary

Zone Lumens %Luminaire

0-30 0-40 0-60 0-90

1420 2131 2376 2378

59.7% 89.6% 99.9% 100.0%

Angle Mean CP Lumens

0

1616

5

1642

10

1705

159

15

1780

20

1762

501

25

1665

30

1478

760

35

1160

40

758

711

45

277

50

25

238

55

7

60

3

7

65

2

70

1

2

75

1

80

0

1

85

0

90

0

0

Single unit data

Height to Initial center beam

Beam

lighted plane foot-candles diameter (ft)*

5'

65

6.5'

6'

45

7.8'

7'

33

9.1'

8'

25

10.4'

9'

20

11.7'

* Beam diameter is where foot-candles drop to 50% of maximum.

Multiple unit data - RCR 2

Spacing Initial center beam

Watts

on center

foot-candles

per sq. ft.

5'

107.0

0.94

6'

70.0

0.62

7'

50.0

0.44

8'

42.0

0.37

9'

34.0

0.30

38' x 38' x 10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances

Efficacy: 111.6 lm/W Report2: STMR-2438

Adjustment factors

Finish

CCT

CL = 100% CC = 95% CD = 87% CZ = 63% WH = 87% BK = 57%

90CRI, 4000K = 102% 90CRI, 3500K = 100% 90CRI, 3000K = 96% 90CRI, 2700K = 92%

Lumens
3000lm = 120% 2500lm = 100% 2000lm = 80% 1500lm = 60% 1000lm = 40%

Coefficients of utilization

Ceiling

80%

70%

50%

30% 0%

Wall 70 50 30 10 50 10 50 10 50 10 0

RCR Zonal cavity method - Effective floor reflectance = 20%

Room Cavity Ratio

0 119 119 119 119 116 116 111 111 106 106 100 1 113 110 108 105 108 104 104 100 100 97 93 2 107 102 98 94 100 93 97 91 94 89 85 3 101 94 89 85 93 84 90 83 88 81 78 4 95 87 81 77 86 76 84 75 82 75 72 5 90 81 75 70 80 70 78 69 76 69 66 6 85 75 69 64 74 64 73 64 71 63 61 7 80 70 64 59 69 59 68 59 67 58 56 8 76 65 59 54 65 54 64 54 63 54 52 9 72 61 55 50 61 50 60 50 59 50 48 10 68 57 51 47 57 47 56 47 55 46 45

1. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products.

CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 9 of 10

C6RA Calculite LED 6" gen 3
Round AirSeal IC frame

3' 3'
5' 30 f.c. 31 f.c. 30 f.c.

Lighting Data - Example
C6RWWCL / C6L25935W illumination on the wall 5' down from the ceiling is 30 f.c. beneath and 31 f.c. between fixtures.

Adjustment factors

Finish

CCT

CL = 100% CC = 95% CD = 87% CZ = 63% WH = 87% BK = 57%

90CRI, 4000K = 102% 90CRI, 3500K = 100% 90CRI, 3000K = 96% 90CRI, 2700K = 92%

Lumens
3000lm = 120% 2500lm = 100% 2000lm = 80% 1500lm = 60% 1000lm = 40%

Open Wall Wash, 2500lm Engine, 90 lm/W at 22W

Candela Curve

400

800

1200

1600 Room side

Wall side

4RA / C6RWWCL / C6L25935W

Output lumens: Input watts: CRI: CCT 1:

1986 lms 22.0 W 90 min 3500K

Efficacy: 90.3 lm/w Report2: STMR-1837

Multiple unit data Footcandles on wall

2' from wall

3' on ctr.

Distance from ceiling in feet

1

25

19

25

2

49

41

49

3

49

47

49

4

39

40

39

5

29

30

29

6

22

23

22

7

17

18

17

8

13

14

13

9

11

11

11

10

9

9

9

12

7

8

7

14

6

6

6

Multiple unit data Footcandles on wall

3' from wall

3' on ctr.

Distance from ceiling in feet

1

9

8

9

2

21

20

21

3

32

30

32

4

33

34

33

5

30

31

30

6

25

26

25

7

20

21

20

8

17

17

17

9

14

14

14

10

11

12

11

12

9

10

9

14

8

8

8

Multiple unit data Footcandles on wall

3' from wall

4' on ctr.

Distance from ceiling in feet

1

7

6

7

2

17

13

17

3

25

21

25

4

26

25

26

5

23

24

23

6

20

20

20

7

17

17

17

8

14

14

14

9

12

12

12

10

10

10

10

12

8

9

8

14

7

8

7

Lensed Wall Wash, 2500lm Engine, 83 lm/W at 22W

Candela Curve
400 800 1200 1600 Room side

4RA / C6RLWCL / C6L25935W

Output lumens: Input watts: CRI: CCT 1:

1830 lms 22.0 W 90 min 3500K

Wall side

Efficacy: 83.2 lm/w Report2: STMR-2241

Multiple unit data Footcandles on wall

2' from wall

3' on ctr.

Distance from ceiling in feet

1

31

25

31

2

49

42

49

3

47

43

47

4

39

37

39

5

30

30

30

6

23

23

23

7

18

18

18

8

14

14

14

9

11

12

11

10

9

10

9

12

8

8

8

14

7

7

7

Multiple unit data Footcandles on wall

3' from wall

3' on ctr.

Distance from ceiling in feet

1

13

13

13

2

25

24

25

3

29

29

29

4

30

30

30

5

28

28

28

6

24

24

24

7

20

21

20

8

17

17

17

9

14

15

14

10

12

12

12

12

10

10

10

14

9

9

9

Multiple unit data Footcandles on wall

3' from wall

4' on ctr.

Distance from ceiling in feet

1

11

9

11

2

21

18

21

3

24

22

24

4

25

23

25

5

23

22

23

6

20

19

20

7

17

17

17

8

14

14

14

9

12

12

12

10

10

10

10

12

9

9

9

14

8

8

8

1. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products.

© 2023 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.
CalculiteLEDgen3_6in_Airseal_C6RA 04/23 page 10 of 10

Signify North America Corporation 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807 Telephone: 800-555-0050

Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3 Telephone: 800-668-9008

All trademarks are owned by Signify Holding or their respective owners. www.lightolier.com



References