Owner's Manual for MEAN WELL models including: PSP-600 series 600W with PFC and Parallel Function, PSP-600 series, 600W with PFC and Parallel Function, PFC and Parallel Function, Parallel Function, Function

PSP-600-24 MEAN WELL - РКС Компоненти - РАДІОМАГ


File Info : application/pdf, 3 Pages, 205.97KB

PDF preview unavailable. Download the PDF instead.

psp-600-spec
600W with PFC and Parallel Function

PSP-600 series



User's Manual

























 

 
SPECIFICATION

 
CNS14336-1

UL62368-1

Bauar t gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1 GB4943.1 TPTC004 IEC62368-1

MODEL

PSP-600-5

PSP-600-12

PSP-600-13.5 PSP-600-15

PSP-600-24

PSP-600-27

PSP-600-48

DC VOLTAGE

5V

12V

13.5V

15V

24V

27V

48V

RATED CURRENT

80A

50A

44.5A

40A

25A

22.2A

12.5A

OUTPUT

CURRENT RANGE

0 ~ 80A

0 ~ 50A

RATED POWER

400W

600W

RIPPLE & NOISE (max.) Note.2 180mVp-p

240mVp-p

VOLTAGE ADJ. RANGE

4.75 ~ 5.5V

VOLTAGE TOLERANCE Note.3 ±2.0%

10 ~ 13.2V ±1.0%

LINE REGULATION

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±0.5%

SETUP, RISE TIME

1500ms, 50ms at full load

HOLD UP TIME (Typ.)

20ms at full load

0 ~ 44.5A 600.75W 240mVp-p
12 ~ 15V ±1.0% ±0.5% ±0.5%

0 ~ 40A 600W 240mVp-p
13.5 ~ 18V ±1.0% ±0.5% ±0.5%

0 ~ 25A 600W 240mVp-p
20 ~ 26.4V ±1.0% ±0.5% ±0.5%

0 ~ 22.2A 599.4W 240mVp-p
24 ~ 30V ±1.0% ±0.5% ±0.5%

0 ~ 12.5A 600W 300mVp-p
41 ~ 56V ±1.0% ±0.5% ±0.5%

VOLTAGE RANGE Note.5 88 ~ 264VAC 124 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

0.95/230VAC 0.99/115VAC at full load

INPUT

EFFICIENCY(Typ.)

79%

84%

85%

85%

86%

86%

87%

AC CURRENT (Typ.) INRUSH CURRENT (Typ.)

6.8A/115VAC 20A/115VAC

3.4A/230VAC 40A/230VAC

LEAKAGE CURRENT

<1.3mA/240VAC

OVERLOAD

105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE OVER TEMPERATURE

5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover

27.6 ~ 32.4V 31 ~ 36.5V

57.6 ~ 67.2V

FUNCTION

REMOTE CONTROL POK SIGNAL WORKING TEMP.

RC+/RC-: Short = power on ; Open = power off
PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V -20 ~ +60 (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL62368-1, TUV BS EN/EN62368-1, CCC GB4943.1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved

SAFETY & WITHSTAND VOLTAGE

EMC

ISOLATION RESISTANCE

(Note 4) EMC EMISSION

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, GB9245, GB17625.1, BSMI CNS13438, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020

MTBF

1132.9K hrs min. Telcordia SR-332 (Bellcore) ; 142.2K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

170*120*93mm (L*W*H)

NOTE

PACKING

1.9Kg; 8pcs/15.5Kg/1.00CUFT











http://www.meanwell.com) 

 The operating altitude is 2000 meters for CCC, 3000 meters for UL,TUV. The ambient temperature derating of 5/1000m is needed for operating altitude

greater than 2000m (6500ft). https://www.meanwell.com/serviceDisclaimer.aspx

File Name:PSP-600-SPEC 2022-08-08

Downloaded from Arrow.com.

600W with PFC and Parallel Function

PSP-600 series

Mechanical Specification

RS Connector(CN5) : JST B-XH or equivalent

Pin No. Assignment Mating Housing

Terminal

1

RS+

JST XHP

JST SXH-001T

2

RS-

or equivalent

or equivalent

Terminal Pin No. Assignment

Pin No. Assignment

1

AC/L

2

AC/N

3

FG

4 P(Current Share)

5 POK

6 R.C.G

7 R.C.

8~11 DC OUTPUT +V

12~15 DC OUTPUT -V

120

8

11.5

1234567

Case No.910A Unit:mm
2-M3 L=4mm max. 2-M3 L=4mm max.
150 185 170 150

Air flow direction

58.3

100

Block Diagram

I/P

EMI FILTER

FG

Derating Curve

93

50

14 max.

2-M3 L=4mm max.

2-M3 L=4mm max.

12

CN5

8 9 10 11 12 13 14 15

9.5

11.5

ACTIVE INRUSH CURRENT LIMITING

RECTIFIERS &
P.F.C.

POWER SWITCHING

O.L.P.

PWM CONTROL

FAN

SIGNAL CONTROL

PFC fosc : 88KHz PWM fosc : 100KHz
POK

RECTIFIERS &
FILTER O.C.P. DETECTION CIRCUIT

CURRENT SHARING CIRCUIT

P RS+ +V -V RC.G.
RC
RS-

O.V.P.

O.T.P.

Output Derating VS Input Voltage

LOAD (%) LOAD(%)

100 Others
80

60

12V

50

40

20

-20

0

10

20

30 40 45

50

60 (HORIZONTAL)

AMBIENT TEMPERATURE ()

100 90 80 70 60 50 40

88 100 115

135

155

INPUT VOLTAGE (V) 60Hz

230 264

File Name:PSP-600-SPEC 2022-08-08

Downloaded from Arrow.com.

600W with PFC and Parallel Function
Control Terminal Instruction Manual
POK(+) RCG(-)

PSP-600 series
RCG RC

L N FG P POK RCG RC

L N FG P POK RCG RC

L N FG P POK RCG RC

+V +V +V +V -V -V -V -V RS+ RS-

+V +V +V +V -V -V -V -V RS+ RS-

+V +V +V +V -V -V -V -V RS+ RS-

+

-

LOAD

+

-

LOAD

POK Signal
POK Signal is the voltage difference between "RCG" and "POK" pin output POK Signal for TTL level signal PSU turn on: 3.3V ~ 5.6V PSU turn off: 0V ~ 1V

Remote Sensing

+

-

LOAD

Remote Control
Power ON: RCG and RC for short Power OFF: RCG and RC for open

Parallel Operation with Remote Sensing
(1)Parallel operation is available by connecting the units shown as below (+S,-S and P are connected mutually in parallel) : (2)The voltage difference among each output should be minimized that less than 0.2V is required. (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)
=(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit. (6) When in parallel operation, the minimum output load should be greater than 3% of total output load.
(Min. load > 3% rated current per unit x number of unit)

LOAD

+V -V

+S

-S

+ - P RCG RS+ RS-
PSU

+ - P RCG RS+ RS-
PSU

+ - P RCG RS+ RS-
PSU

+ - P RCG RS+ RS-
PSU

Downloaded from Arrow.com.

File Name:PSP-600-SPEC 2022-08-08



References