Instruction Manual for MOLLET models including: SFA-Q Silo Filling Device with Pinch Valve, SFA-Q, Silo Filling Device with Pinch Valve, Silo Filling Device, Filling Device, Device

14-7 SFA-Q Operating Instruction SFAQ-BA 02-22 en

admin

navodila za uporabo MOLOSsafe

MOLOSsafe SFA MOLLET - ELPRO


File Info : application/pdf, 8 Pages, 1.66MB

navodila-za-uporabo MOLOSsafe
M LLET
Füllstandtechnik
Silo filling device
with pinch valve

GmbH

SFA-Q

Operating instructions

Index

Page

Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
Operating instructions
1. Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
1.1 Extent of delivery 1.2 Intended use 1.3 Function 1.4 Technical data 1.5 Materials
2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
2.1 Preparation
2.2 Mechanical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04 2.3 Compressed air connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
2.4 Electrical connection
3. Circuit diagram and function diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
4. Utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
4.1 General instructions 4.2 Putting into operation 4.3 Normal operation 4.4 Inexpert handling
5. Maintenance and servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
5.1 General information 5.2 Maintenance 5.3 Servicing
6. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
7. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
8. Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07

MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 03/20 © by MOLLET SFAQ-BA 01

M LLET
Füllstandtechnik

GmbH

Silo filling device
SFA-Q

Read and follow these safety instructions first and take notice of the operating instructions.

Safety instructions

1. The installation, maintenance, initial operation, removal and repair has to be carried out by qualified experts with knowledge about electrical equipment and know-how about handling of pressure equipment and pneumatic pressure units.

2. The statutory and other applicable regulations and standards have to be noticed and kept.

3. Comply with the specifications on the data plate.

4. The pressure and temperature details given by the data plate have to be kept.

5. A fuse (with max. 4 A) has to be connected in series to the supply voltage of the control valve.

6. A pressure-reducing valve has to be installed in the control pressure supply line and it has to be set at the given control pressure.

7. The process pressure (delivery pressure) and the control pressure given by the type plate must not be exceeded.

8. Initial operation and pressure admission only when the silo filling device is completely installed.

9. When the silo filling device is damaged the compressed air and voltage supply has to be shut off immediately and it is to released from any pressure e.g. by removal of the control medium conveying line.

10. Any work at the filling device has to be carried out in pressure-free and de-energized condition only.

!

11. Read and follow the attached safety instructions for the single units.

12. By usage in explosive hazardous areas read and follow the enclosed safety instructions of the operating instructions and the explosive protection informations of the single units.
13. All product touching parts have to be made of stainless-steel if a) rust-containing particles (like rust film) are existent in the conveying medium and a gaseous explosive atmosphere is conveyed. b) combustible dusts with a minimum ignition energy less than 3 mJ or with a minimum ignition temperature below +300 °C (BAM procedure) are conveyed.

02 SFAQ-BA 02/22 © by MOLLET Operating instruction MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846

M LLET
Füllstandtechnik

GmbH

Silo filling device
SFA-Q

Operating instructions
1. Specification
1.1 Extent of delivery
Gasket
Pinch valve Control valve (3/2-way solenoid valve)
Protection tube

Connection coupling Swivelling lever with limit switch

Padlock with 2 keys

011-0200

Extent of delivery is depending on the choice of options.

1.2 Intended use
The device is to be mounted at the filling pipe of silos, which were filled pneumatically by a silo vehicle, to connect the filling hose, for contacting and to shut-off the filling pipe. In its capacity as part of the silo filling device, the pinch valve is designed, build and approved as a ,,pressure-maintaining component" in accordance to the Pressure Equipment Directive 2014/68/EU.
1.3 Function
The swivelling lever has to be swivelled aside to connect the filling hose to the coupling. The limit switch, which is integrated in the swivelling lever, signalizes to the control unit that a hose has been attached.
The pinch valve will be actuated by compressed air via a control valve (Solenoid valve). The pinch valve is closed when deenergized.

1.4 Technical data

Manufacturer

MOLLET Füllstandtechnik GmbH

Address

Industriepark RIO 103 74706 Osterburken

Name

Silo filling device

Type

SFA-Q ...

Process temperatuTre(Process) -25 °C ...+80 °C

Ambient temperature Ta -20 °C ...+40 °C

Supply voltage

Control valve last digit 1

230 V AC 50 ... 60 Hz

Control valve last digit 2

24 V DC

Control valve last digit 3

24 V AC

Signal contact

of the swivelling lever
Switching ability Switching voltage

Contact

see type plate and appendixes to the operating instructions

Type of protection

IP IP65 according to DIN EN 60529

Process
Delivery air

pressure
pressure

p(Process)

2.0

bar

...

2.5

bar

Control pressure

Weight

DN065 DN080 DN100

Mounting position

4.5 bar ... 5.0 bar Compressed air, oil and water-free

15.0 kg 15.5 kg 19.8 kg

completely assembled

vertical to horizontal

1.5 Materials Pinch valve Housing Clamping sleeves Hose NR Hose NW Hose NRE
Protection tube Swivelling lever Connection coupling
-

depending on choice of option Aluminium Aluminium or stainless steel Caoutchouc, resistant to abrasion, Caoutchouc, inside white for food Caoutchouc contuctible, (for ATEX valves) Steel, galvanized or stainless steel Steel, galvanized Aluminium or stainless steel

2. Installation
2.1 Preparation
- Before starting to work at the silo filling device read and follow the safety instructions and the operating instructions!
- The silo filling device is completely assembled with control valve, swivelling lever with limit switch and connection coupling.
- Remove the weld-on flange and the sealing. (Put screws and washers aside)
- To avoid damaging the silo filling device don't carry out welding works at or nearby the filling device.

MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 03/20 © by MOLLET SFAQ-BA 03

M LLET
Füllstandtechnik
2. Continuation installation
Filling tube
DN065 = Ø185 DN080 = Ø200 DN100 = Ø220

GmbH

Silo filling device
SFA-Q

2.2 Mechanical connections a Push the weld-on flange on the tube.
weld tight

b Adjust the boreholes of the flange as shown here and weld the flange in this position.

Wall

no obstacle

DN065 = 450 DN080 = 480 DN100 = 520

011-1001

Swing range 230

c Put the sealing at the flange of the silo filling device and fasten it on in such way that, if a wall is behind it, the swivelling lever points to the right, to the left or to the front or, if no obstacle is present, backwards.

DN065 = 1750 ... 1850 DN080 = 1780 ... 1880 DN100 = 1820 ... 1920 approx. 1300 ... 1400

011-1000

d In case of slanting or horizontal pipe the silo filling device has to be mounted always on the upper side, the lever must fall into the final position by ist own weight.

04 SFAQ-BA

011-1002
03/20 © by MOLLET Operating instruction

The swivelling lever has to swivel freely.
011-1003
MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846

M LLET
Füllstandtechnik
2.3 Compressed air connection - Connect the control valve with the oil and water-free compressed air supply by a weather-resisting hose. - Adjust the pressure reducing valve at 4.5 bar ... 5.0 bar.

GmbH

Silo filling device
SFA-Q

Hose 8x1 weather-resisting
Cable 3x1.0 mm²
Loop to compensate the swivelling motion
Cable at the swivelling lever with limit switch SES 5x0.75 mm² SIS 3x0.34 mm² according to choice of option 2 m, 5 m or 10 m SNS 2x0.34 mm²

2.4 Electrical connection

011-1004

- Connect the control valve with the control cabinet according to the local and statutory rules and regulations.

- Subsequently connect the cable of the swivelling lever with limit switch with the assigned terminal of the control cabinet.

3. Circuit diagram and function diagram

Control valve

Control pressure 4.5 bar ... 5.0 bar

Compressed air oil and water-free

Compressed air consumption DN065 = 5.4 Nl

per switching function

DN080 = 6.8 Nl

DN100 = 8.0 Nl

Swivelling lever with limit switch according to choice of option

SNS

SIS

br BN bl BU

br BN bl BU sw BK

011-AP02

011-AP01

PE L

N

SES

BN br

BK sw

gr/ge bl GN/YE BU

sw/ws BK/WH
011-AP00

Pinch valve
011-AP03

MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 03/20 © by MOLLET SFAQ-BA 05

M LLET
Füllstandtechnik

GmbH

Silo filling device
SFA-Q

4. Utilization
4.1 General instructions - The silo filling device with its equipment may be operated and monitored by expert and instructed personnel only so that employees and other persons will not be brought in danger. - The operating instructions with the safety instructions have to be available to the operating and maintenance personnel. - In its capacity as part of the silo filling device, the pinch valve is a ,,pressure-maintaining component" in the meaning of the Pressure Equipment Directive 2014/68/EU. Therefore take care of the country of installation's national regulations about the operation of pressure equipment.
4.2 Putting into operation Put the silo filling device in operation only when:
- The silo filling device is fix connected with the filling pipe, - a pressure reducing valve is mounted at the compressed air
supply pipe and the control pressure is adjusted, - the electrical connections are done correctly and - the swivelling lever can swivel freely, the connecting cable is laid
out flexible and can't be damaged by the motion.
4.3 Normal operation - Use the silo filling device in its intended application only. - Keep the safety instructions of all units. - If the silo filling device is damaged put it out of operation immediately and relieve it from any pressure. - If the maximum permissible pressure or temperature was exceeded check the hose of the pinch valve.
4.4 Inexpert handling - Ignoring the safety instructions and the operating instructions. - Not intended use. - Operating of the pinch valve by personnel which is not authorized or not proper instructed. - Mounting of spare parts which are no original parts. - Violation against applicable law and standards.

5. Maintenance and servicing
5.1 General information - Carry out maintenance and repair work only when the silo filling device is disconnected from the control pressure and voltage supply lines and released from any pressure. - If it's to reckon with the exhaust of hazardous substances during the maintenance special protection measures (e.g. personal protection equipment) are necessary.
5.2 Maintenance Inspect in regular intervals: - The correct pre-set of the pressure-reducing valve in the compressed air supply line, - the hose of the pinch valve for tear and wear, - all connections and joints for tight fit, - the swivelling lever with limit switch for freedom of movement.
Schedule the inspection intervals according to - the kind of material which has to be shut off and it´s
abrasiveness, - the frequency of use but at least once a year.
5.3 Servicing - Damaged parts have immediately replaced with similar. - The silo filling device must not be used until the complete restoration of the proper function.
-
6. Storage
- Store the silo filling device dry and dust-free. - When the storage period lasts longer than 4 weeks the openings
of the silo filling device have to be closed with appropriate means (e.g. blank cap or blind flange) to protect the rubber hose from pollution.
-
7. Disposal
- The silo filling device can be recycled. - The disposal applies to the valid environmental guidelines
according to the location of the carrier and the local manufacturing conditions.
-

06 SFAQ-BA 03/20 © by MOLLET Operating instruction MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846

M LLET
Füllstandtechnik
Spare parts
Silo filling device with pinch valve
Type SFA-Q ... DN 65, DN 80 and 100

GmbH

Silo filling device
SFA-Q
Silo filling device with pich valve Type SFA-Q ... DN 65, 80 and 100

Gasket Hexagonal nut

DN 65 077-002-DIR-ABF
0934-05-000-STV

DN 80 090-002-DIR-ABF
0934-05-000-STV

DN 100 115-002-DIR-ABF
0934-05-000-STV

Cylinder head screw

0912-05-045-STV

0912-05-045-STV

0912-05-045-STV

3/2-way solenoid valve with all components

230 V AC . . . . . 0 820 005 250B 24 V DC . . . . . . 0 820 005 251B 24 V AC . . . . . . 0 820 005 253B

Pinch valve depending on version
Threaded pin

QV-065-FG-AX-XX 0914-06X010-V4A

QV-080-FG-AX-XX 0914-06X010-V4A

QV-100-FG-AX-XX 0914-06X010-V4A

Protection tube made of
Steel, galvanized 1.4571 / 316 Ti Aluminium

065-200-NIP-STV 065-200-NIP-V4A 065-200-NIP-AL

Swivelling lever with integrated limit switch
2=2 m, 5=5 m, 0=10 m Cable length

SES-065-X SIS-065-X SNS-065-X

080-200-NIP-STV 080-200-NIP-V4A 080-200-NIP-AL
SES-080-X SIS-080-X SNS-080-X

100-200-NIP-STV 100-200-NIP-V4A 100-200-NIP-AL
SES-100-X SIS-100-X SNS-100-X

Padlock with 2 keys

KS-VS025-G, or optional KS-VS025-U,

the same key for all locks a separate key for every lock

Thread pin

0914-05X010-V4A

0914-05X010-V4A

0914-05X010-V4A

Connection coupling made of

Aluminium

K-FSZ075IG2½-AL K-FSZ075IG3-AL

K-FSZ110IG4-AL

Aluminium /1.4581 / 318

K-FSZ110IG4-AV

011-0800

1.4581 / 318

K-FSZ075IG2½-VA K-FSZ075IG3-VA

K-FSZ110IG4-VA

MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846 Operating instruction 02/22 © by MOLLET SFAQ-BA 07