Disclaimer
The interceptor units are also steering equipment and it is the sole responsibility of the navigator-operator to ensure that, at any point, any problem that will alter the boat's course, rising from malfunction of interceptors, should be dealt immediately by the operator. At no circumstances, fault of our interceptor equipment leading to any kind of accident, creates liability for the manufacturer.
Trademark Notice
Hydrotab is a registered trademark of Olympic Engineering Ltd, Greece. All other trademarks, trade names or company names referenced herein are used for identification only and are property of their respective owners.
Patent Notice
The Hydrotab products are protected by patents and industrial design patents, patents pending or design patents pending.
Declaration of conformity
This product conforms to the following Electromagnetic Compatibility (EMC) regulations and standards for use in marine environments. CE EN 60945
Technical information and Documentation
The technical information provided in this document was accurate and correct at the corresponding production time of the Hydrotab interceptors. Our operating principal for improving the manufactured product, may lead to changes regarding its specifications without prior notice. Liability will not be accepted for any inaccuracy considering the product and the user manual.
Fair use statement
This manual can be printed or copied for your own use only. Copies should not be provided to third parties and manual should not be commercialized.
Product Disposal
Waste removal of this product must be according to the Waste Electrical and Electronic Equipment (WEEE) Directive.
Product Registration
Please register your product online in order the warranty to be valid.
Air Unit Max Installation
WARNING: THE AIR UNIT MUST BE INSTALLED IN A COMPARTMENT FREE OF EXPLOSIVE OR FLAMMABLE GASES.
WARNING: THE AIR UNIT MUST BE INSTALLED 20cm BELOW ANY SURFACE THAT LOCATES ABOVE IT.
WARNING: PLEASE INSURE THAT THE AIR UNIT IS INSTALLED ACCORDING TO THE IP30 LIMITATIONS.
IP30: Protected from tools and wires greater than 2.5 millimeters. Not protected from liquids.
Diagram showing the Air Unit MAX with indicators for 20cm clearance above and to the sides. A prominent warning states: DO NOT MOUNT the Air Unit upside-down.
-
Step 1
Find a clear surface, place the Air Unit Max, and mark the holes with a pencil.
-
Step 2
Make holes with Ø3 drill.
-
Step 3
Mount the Air Unit Max with the given screws (M4.8x25).
Pneumatic Connection
Diagram illustrating pneumatic connections. The unit has ports labeled "STBD" and "PORT".
-
Step 4
Connect the push-in fitting.
-
Step 5
Cut the 8mm pipe at the proper length and connect it to the Air Unit.
Technical Data & Dimensions
Line drawing of the Air Unit MAX with labels A, B, and C pointing to its overall dimensions.
Dimension | A | B | C |
---|---|---|---|
Size | 259 mm | 143 mm | 459 mm |
Air Unit Max DataSheet
Compressor power | 380 W |
Air compressor type | Brushless, oil-free |
Voltage | 24 V |
Amps | 15 A |
In Line Fuse | 30 A |
Max pressure | 4 bar |
Installation Diagrams
Direct Installation Diagram
Schematic showing the Air Unit MAX connected to a Moby Controller and an optional Flybridge controller via NMEA 2000 cables. Indicates power connection "TO 30A + FUSE" and the need for an "INLINE TERMINATOR". Cables used are CABLE 10m - FF, CABLE 3m - F, and CABLE 3m - MF.
In case a new NMEA 2000 instrument to be added, a proper NMEA Network must be built.
Installation diagram on existing NMEA Network
Similar schematic showing the Air Unit MAX connecting to an existing NMEA 2000 network, using terminators and specified cables (CABLE 3m - MF, CABLE 3m - F).
Electrical and Pneumatic Diagrams
Air Unit Max Electrical Diagram
Detailed wiring diagram showing connections to the battery, compressor (M), timer, switches, NMEA 2000 interface (CAN-H, CAN-L, COM, etc.), and solenoid valves (C1-C5). Includes a transformer (Tr1) and fuse (F1). A note emphasizes: IMPORTANT: THE SWITCHES MUST BE STRICTLY SET AS SHOWN (DIP1, DIP2, DIP3, DIP4 RIGHT).
Legend:
- Port Valves
- Starboard Valves
- Exhaust Valve
Air Unit Max Pneumatic Diagram
Schematic of the valve group (C1-C5) and the compressor (M).
SYMBOL | Part No | Description |
---|---|---|
C1-C4 | PNE-01202 | SOLENOIDS 24V (PORT-STARBOARD) |
C5 | PNE-01243 | EXHAUST SOLENOID 12V |
PCB | PCB-00029 | AIR-N2K |
TIMER | ELE-00698 | ELECTRONIC DELAY |
M | PNE-01242A | BRACELESS COMPRESSOR, 380W |
T1 | ELE-00550 | THERMISTOR |
NMEA 2000 | ELE-00535 | NMEA 5-POLE CABLE |
F1 | ELE-00701 | CYLINDRICAL FUSE 3A |
Tr1 | PNE-01242B | TRANSFORMER 230V/24V |
Spare Parts
Spare Parts - Air Unit Max
Exploded view diagram of the Air Unit MAX with numbered components.
BOM ID | PartNo | Description | QTY. |
---|---|---|---|
3 | ELE-00535 | 5PIN PCB MALE CONNECTOR | 1 |
4 | ELE-00647 | MINI USB PORT, FEMALE | 1 |
5 | ELE-00698 | RELAY TIMER | 1 |
8 | GEN-00405 | COVER | 1 |
9 | GEN-00529 | VENTOURI TUBE | 1 |
12 | LAS-01277 | ELECTRONICS HOLDER | 1 |
16 | PCB-00029 | PCB FOR NMEA 2000 | 1 |
21 | PNE-00633 | ELBOW MALE ADAPTOR 1/4-8/6 | 1 |
29 | PNE-01242A | COMPRESSOR | 1 |
30 | PNE-01242B | TRASNFORMER | 1 |
31 | PNE-01242C | FILTER | 1 |
36 | RUB-00162 | PCB RUBBER BASE | 1 |
37 | RUB-00163 | VENTOURI RUBBER SUPPORT | 1 |
44 | ELE-00057 | CABLE GLAND PG13.5 | 1 |
Spare Parts - Valves Assembly
Diagram showing components of the valves assembly.
BOM ID | PartNo | Description | QTY. |
---|---|---|---|
50 | PNE-00101 | NIPPLE, TAPER, 1/4 (M) - 1/8 (M) | 4 |
51 | PNE-01202 | FLD CTRL VALVE NC 1/4 Ø8 24VDC | 4 |
52 | PNE-01243 | FLD CTRL VALVE NO 1/4 Ø8 12VDC | 1 |
53 | PNE-00222 | ELBOW MALE ADAPTOR 6/4-1/8 | 3 |
54 | PNE-00043 | FITTING, ELBOW, 1/4 - Ø6 | 3 |
55 | REV-00583 | 20x20 FITTING ADAPTER 1/4 | 1 |
56 | REV-00585 | 25x25 FITTING ADAPTER 1/4 | 1 |
57 | REV-00584 | 20x20 FITTING ADAPTER 1/4 | 1 |
58 | PNE-00092 | SAFETY VALVE, 1/8 | 1 |
64 | PNE-00721 | ALUMINIUM WASHER, 1/8 | 2 |
65 | REV-00588 | FITTING | 2 |
Troubleshooting
Flowchart for troubleshooting the Air Unit MAX:
- Issue: Moby Controller is ON but flaps do not operate on manual.
- Action: Go to System Information. Do you notice N2K error and Temperature Offline?
-
If No to Issue 1:
- Open the air unit.
- When buttons ↑↓←→ are pressed, do you notice the red lights on the PCB on?
-
If Yes to red lights on PCB:
- Is there power supply to the air unit?
- Are the fuses ok?
- Does the PCB have power supply?
-
If Yes to power supply: When the red lights are on, does the compressor work?
- If Yes to compressor: 1) Check for replacement the compressor relay and 20A fuses. 2) The compressor is burned.
- If No to compressor: Replace air unit PCB.
-
If No to power supply: Use a jumper wire between COM and LDRU, RDLU, DN, UP. Do you notice relevant red lights on?
- If Yes to relevant red lights: NMEA Network communication failure due to cabling or PCB fault.
- If No to relevant red lights: 1) Reset or replace the fuses. 2) Check the wires which are connected to PCB and transformer. 3) Replace the transformer.
-
If No to red lights on PCB: When the red lights are on, do the relevant solenoids operate?
- If Yes to solenoids: Air leakage by faulty flap or air unit.
- If No to solenoids: Burned solenoid or pilot.
- If Yes to Issue 1 (N2K error/Temp Offline): Use a jumper wire between COM and LDRU, RDLU, DN, UP. Do you notice relevant red lights on? (Follow steps as above for "No to power supply" scenario).
Warranty Conditions
Interceptor Units (excluding complete systems):
- FW, TS and BT Series: 5-year Warranty.
- SR Series: 2-year Warranty.
Recoil springs, electrical/electronic parts and devices: 2-year warranty.
Anodes (consumables) are not included in the warranty (for BT, FW, TS Series).
Hydrotab's warranty only covers the repair or replacement of spare parts.
System selections
It is the sole responsibility of the buyer to choose the correct system. Even with Hydrotab's suggestion for a system, the overall responsibility is with the buyer.
Limited warranty
Provided that the system has been installed in accordance with the installation manual and no damage has been caused due to improper handling or practices, Hydrotab will replace any defective parts or parts that failed due to improper manufacturing within the applicable warranty period.
Hydrotab only covers the parts' replacement. Fitting or shipping costs are not covered by warranty.
Hydrotab will select if it will repair or replace any given part.
Repaired or replaced products will assume the remainder of the warranty time and under no conditions will the full time of warranty be renewed.
Limited warranty periods
Standard limited warranty period is two (2) years from the product shipment from Hydrotab's premises.
Extended limited warranty period
This is provided in case:
- a) Hydrotab trim system is included as equipment of a newly purchased boat directly from the boat-builder or his reseller.
- b) Hydrotab trim system has been purchased through a Hydrotab dealer.
The extended limited warranty period is valid for three (3) years from the shipping date, provided that the customer has downloaded, completed and submitted the online registration form within one month (30) days from the purchase. The URL for registration is: https://www.hydrotab.gr/product-registration
In case the dealer sells separate units of Interceptors, Air Units and Controllers that constitute a full system that is not initially sold (as a complete system) by Hydrotab, the dealer has the responsibility to provide the separate Serial Numbers for the Interceptors, Air Units and Controllers and guide the end user for the proper registration of his serial numbers for the extended warranty to be valid.
The authorized dealer is responsible for the product's service.
For any services or spare parts requirements and replacements during the warranty period, the original invoice is necessary to be presented.
For the replacement of any part of the system (interceptors, Air Unit, any controller etc.) under warranty, the replaced parts must be returned to Hydrotab Marine Engineering for inspection, otherwise warranty is not valid.
Cost of dismantling - assembly and spare parts transportation is borne by the user.
The warranty does not foresee, under any circumstances, replacement of the whole Hydrotab system.
What is not covered by the warranty:
- Damage caused by the lack or non-replacement of worn anodes (for BT, FW, TS Series).
- Damage caused by improper installation and use not consistent with the manual.
- Damage with external visible deformation of the product caused by misuse of the user or other external causes.
- Damage to any component caused during transportation, installation or repair from non-authorized personnel.
- Conversions or modifications made after the initial sale.
N. Triantafyllis Ltd (Hydrotab Marine Engineering) is not liable for any incidental, indirect or consequential damages or losses, including, without limitation: travel expenses, transport, lifting and hauling, costs, loss of income, loss of time, loss of property, loss of profits, personal injury or damage of any products, different from those that the company distributes. Any further (except the above mentioned) commitment of the intermediate dealer regarding the sale terms or servicing of Hydrotab products does not create any liability of our company.
Contact Information
HydroTab Marine Engineering
4, Papazoglou str.
GR-17778 Athens
Greece
Email: info@hydrotab.gr
Website: www.hydrotab.gr
Revision: REV.C