Product Overview
Description
The NVS-20231602AM is a two-channel stereo professional power amplifier with low distortion and high efficiency. It is equipped with reliable protection of overvoltage, under-voltage, DC, short circuit, and alarming functions. BTL connection is available. It is suitable for conference systems, meeting rooms, and live performances.
Features
- Two-channel stereo professional power amplifier
- Individual volume control for each channel
- Equipped with stereo, parallel, and BTL bridge three operating mode options for the choice of working mode switch selection
- Equipped with short circuit protection, DC protection, power off, and a variety of protection and alarm functions
- Each channel is equipped with LED working status indication, low noise design
- Equipped with XLR signal input interface (female base) and XLR signal output interface (male base)
Appearance Description
Front Panel
The front panel features:
- CH-1 Input Level Adjustment Knob
- Power Switch
- CH-2 Input Level Adjustment Knob
- Work Status Indicator Light
Operational Status Indicators:
- PRO (Protection Status - Yellow): Indicates a protection condition in CH-1 or CH-2. This LED illuminates during the initial 3-5 seconds of power-on or just after power-off while the amplifier circuitry stabilizes, when internal component temperatures exceed 90°C, or in the event of a general amplifier fault.
- CLIP (Clipping Indicator - Red): Indicates signal clipping or abnormal output conditions. When the output signal amplitude nears the maximum power limit, it indicates potential distortion. Reduce input level to prevent signal degradation. If a signal is present but there is no audio output and the indicator remains lit, a short circuit at the speaker load is suspected. Power down the amplifier, correct the fault, and restart operation.
- SIG (Signal Presence Indicator - Red): Illuminates when a valid output signal is detected on CH-1 or CH-2, confirming normal amplifier operation.
- BRI (Bridge Mode Indicator - Green): Indicates that the amplifier is operating in Bridge Mode. In this configuration, input is accepted only via CH-1, and output is bridged across both channels.
- STR (Stereo Mode Indicator - Green): Indicates that the amplifier is operating in Stereo Mode, with independent input and output for each channel.
- PAR (Parallel Mode Indicator - Green): Indicates that the amplifier is operating in Parallel Mode. In this mode, the input signal from CH-1 is simultaneously fed to both amplifier channels.
Rear Panel
The rear panel includes:
- CH-1/CH-2 Input Connector: Standard XLR (3-pin female) connectors. Pin 1: Ground (Shield), Pin 2: Hot (+, Non-inverting Signal), Pin 3: Cold (-, Inverting Signal).
- CH-1/CH-2 Signal Link Output Connector: Standard XLR (3-pin male) connectors for daisy-chaining. Wiring configuration: Pin 1: Ground (Shield), Pin 2: Hot (+, Non-inverting Signal), Pin 3: Cold (-, Inverting Signal).
- CH-1/CH-2 Limiter Switch: Activates the integrated output limiter on each channel to prevent distortion and protect speakers.
- CH-1/CH-2 35Hz High-Pass Filter: Attenuates frequencies below 35Hz to protect low-frequency transducers from excessive excursion and mechanical damage due to subsonic content.
- Operation Mode Selector Switch: Selects the amplifier's working configuration: Stereo Mode, Bridge Mode, or Parallel Mode.
- CH-1/CH-2 Subharmonic Enhancer (Bass Exciter): Adjusts the intensity of artificially generated low-frequency content. Use with caution as excessive enhancement may damage speakers.
- CH-1/CH-2 SPEAKON Output Connector: Professional-grade SPEAKON connectors for speaker output. Wiring: 1+: Positive terminal, 1-: Negative terminal, 2+/2-: Additional signal paths.
- Amplifier Output Binding Posts: Provides alternative speaker connection via binding posts or banana plugs.
- Resettable Circuit Breaker: Automatically disconnects power in case of malfunction or overload. Press to restore operation after resolving the issue.
- AC Mains Power Inlet: Standard IEC power socket for AC mains power supply. Use only properly rated power cables.
- Cooling Exhaust Vent: Forced-air cooling outlet for heat dissipation. Do not obstruct the vent to maintain adequate airflow and prevent overheating.
Specifications
Item No. | NVS-20231602AM |
---|---|
Rated Output / Per Channel, 8Ω | 800W |
Rated Output / Per Channel, 4Ω | 1200W |
Rated Output / BTL, 8Ω | 2100W |
Frequency Response | 20Hz-20kHz (±1dB) |
Total Harmonic Distortion | < 0.1% |
Signal to Noise Ratio | ≥98dB |
Input Sensitivity | 1.0V |
Input impedance | 20kΩ/balance, 10kΩ/unbalance |
Damping coefficient | >230/8Ω,1kHz |
Channel crosstalk | <-62dB |
Conversion rate | 15V/μs |
Power Supply | AC220-240V/50Hz |
Weight | 18kg |
Dimension (L×W×H) | 484×460.5×88mm |
Safety Precautions
CAUTION
- When the power switch is “OFF”, the machine is not completely disconnected from the power grid.
- For safety, pull the power cord plug out of the socket when not using the equipment.
- The equipment shall not be subject to water drops or splashes, and objects filled with water shall not be placed on the equipment.
- To reduce the risk of electric shock, do not remove the cover. If necessary, please ask professional personnel to repair.
- The symbol on the rear panel indicates hazardous live. Connection of these terminals must be operated by instructed personnel.
- The equipment is connected to the power grid through the power cord plug. In case of equipment failure or danger, disconnect by pulling out the power cord plug.
- Place the power socket in a position where the power cord can be conveniently plugged and unplugged.
Technical Description
- When the power switch is in the "OFF" position, the unit remains electrically connected to the AC mains supply.
- For safety purposes, always disconnect the AC power cord from the outlet when the equipment is not in operation.
- This equipment must not be exposed to liquid ingress (e.g., dripping or splashing). Do not place liquid-filled containers (such as vases) on or near the unit.
- To prevent electrical shock, do not remove the unit's cover. All servicing should be carried out by qualified technical personnel.
- The rear panel contains a hazardous voltage warning symbol, indicating terminals with live electrical potential. These connections must only be handled by authorized or trained personnel.
- The device is powered via a detachable mains power cord. In the event of a fault or hazard, the mains supply can be fully disconnected by unplugging the power cord.
- Ensure the AC outlet is installed in an accessible location so the power cord can be easily connected or disconnected in an emergency.
File Info : application/pdf, 10 Pages, 4.56MB
DocumentDocumentReferences
3.0.24 (5.1.10)Related Documents
![]() |
Norden Digital Power Amplifier User Manual User manual for Norden Digital Power Amplifiers, covering models NVS-20100252AM, NVS-20110502AM, NVS-20011002AM, NVS-20130244AM, NVS-20140504AM, and NVS-20151004AM. Includes product overview, features, appearance description, connection diagrams, and technical specifications. |
![]() |
Norden 6 Zone Integrated PA Host with Amplifier User Manual User manual for the Norden NVS-PA0028006CP/NVS-PA0029006CP/NVS-PA0030006CP/NVS-PA0031006CP 6 Zone Integrated PA Host with Amplifier. Covers product overview, features, appearance (front and rear panels), operating instructions, and specifications. |
![]() |
Norden 6 Zone Integrated PA Host with Amplifier User Manual User manual for the Norden NVS-PA0028006CP/NVS-PA0029006CP/NVS-PA0030006CP/NVS-PA0031006CP 6 Zone Integrated PA Host with Amplifier. Covers product overview, features, appearance, operating instructions, and specifications. |
![]() |
NORDEN Box Speaker User Manual with Wall Mount Bracket Comprehensive user manual for NORDEN Box Speakers (NVS series) with wall mount brackets. Covers product overview, features, material characteristics, installation, rear panel details, and technical specifications including frequency response, distortion, and directivity patterns. |
![]() |
Norden NVS-PA0018006CP 350W 6-Zone Mixer Amplifier User Manual User manual for the Norden NVS-PA0018006CP, a 350W 6-zone integrated mixer amplifier with paging microphone connectivity. Details product overview, features, front and rear panel descriptions, connection instructions, and technical specifications. |
![]() |
Norden NVS-IP100029SP: 2x30W Wall Mount IP Speaker - Technical Overview & Specifications Discover the Norden NVS-IP100029SP, a high-performance 2x30W wall mount IP speaker. Featuring advanced network audio decoding, Class-D amplification, and DSP, it ensures clear audio for scalable IP PA systems. Includes SIP support and PoE power. |
![]() |
NVS-IP100028AA 4 Channel 2-Way Audio Interface User Manual User manual for the NVS-IP100028AA 4 Channel 2-Way Audio Interface by Norden. Covers product overview, features, hardware interface, wiring, network settings, web interface login, parameter configuration, system management, and troubleshooting. |
![]() |
Norden NVS-30150001MP Wireless Classroom Microphone Datasheet Detailed specifications and features of the Norden NVS-30150001MP Wireless Classroom Microphone, designed for AV setups and classrooms. Includes technical data, front panel controls, and ordering information. |