Installation Guide for Fanvil models including: i31S, Video Door Phone
7 mag 2020 —
Index of /wp-content/uploads/pdfs
7 mai 2020 ... Figure 2 Wall Mounting. A. Place the mounting template with dimensions on the surface of a wall in a desired flat position.
File Info : application/pdf, 14 Pages, 1,016.86KB
DocumentDocumenti31S WWW.FANVIL.COM Video Door Phone Quick Installation Guide Table of Contents 1. Package Contents............................................................................................... 1 2. Physical Specifications....................................................................................... 1 3. Installation......................................................................................................... 5 4. Searching Door Phone..................................................................................... 8 5. SIP Door Phone Setting.................................................................................... 9 6. Door Unlocking Setting.................................................................................... 10 1. Package Contents 2. Physical Specifications Device size Weight 1) Front Panel 223 x 130 x 74mm 1800g Speaker Lock status Call status Ring status Network and registration status Infrared light Camera photoresistor Numeric keypad (password and dialing) RFID area Dss Key MICs 1 Interface Camera Infrared light & Photoresistor Speaker MIC RFID Reader Button Definition Button DSS Key Numeric Keyboard Get the video. Description The Compensate for lack of ambient light The door phone has a built-in speaker for convenient communication and alert use. The door phone has a built-in microphone hidden in the pinhole located on the front panel. Use RFID cards to unlock the door by touching RFID reader of device. Description Press the Button, calling or request to open the door. Input password to open the door or call. LED Definition LED Lock Call Ring Network & SIP Registration Status Steady Blue off Blinks per second Steady Blue off Steady Blue off Blinks per second off Blinks every 3 seconds Steady Blue Description Door unlocking Door locking Hold Call Hold On Hook Ringing On Hook Network error Network is normal, SIP is not registered SIP Registration failed SIP Registration succeeded 2) Port Definition After removing the Back Panel of device, there are one terminal block connectors for power and lock control connection as shown in the picture below. Power and lock connector WAN Port JP1 Jumper 2 Network Connector Power and Electric-lock Connector 1 2 +DC12V VSS 12V DC Input 3 4 5 NC COM NO Electric-lock switch 6 7 S-IN S-OUT Indoor switch JP1 Jumper There are two modes for power supply of electric-lock as shown in the picture below. (The default is "Passive Mode "). Passive Mode: When the electric-lock starting current is more than 12V/500mA, need to use the external drive mode, the electric lock interface for short circuit output control. Active Mode : When the electric-lock starting current is less than 12V/500mA, can use the internal drive mode, the electric lock interface is 12V DC output. Jumper in passive mode Jumper in active mode 3 Wiring instructions NO: Normally Open Contact COM: Common Contact NC: Normally Close Contact Driving Mode Electric-lock Mode Active No electricity Electrify Passive when open when open JP1 Jumper Connections 4 3. Installation Front Panel Main Part of Intercom Rain Shade Figure 1 Three Major Parts of i31S Back Panel Step 1: Installation preparation A. Check the following contents: z Hex wrench x 1 z RJ45 plugs x 2 (1 spare) z TA5 x 40mm screws x 4 z 35mm screw anchors x4 B. Tools that may be required: z Hex wrench z Phillips screwdriver (Ph2 or Ph3), hammer, RJ45 crimper z Electric impact drill with an 6mm drill bit Step 2: Drilling Figure 2 Wall Mounting A. Place the mounting template with dimensions on the surface of a wall in a desired flat position. B. Use an electric drill to drill the 4 holes marked on the mounting template. It is recommended to drill about 50mm deep. Remove the template when finishing drilling. C. Push or hammer screw anchors into the drilled holes. 5 Step 3: Removing hanging shell A. With L-shaped screwdriver, unpack the front panel as diagram (3) (Counter-clockwise) and (4) Figure 3 B. Figure 4 Step 4: Back panel fixing and cabling Figure 5 Figure 6 Figure 7 A. Select the hole for cable supply, 15cm to 20cm cable length is recommended. Note: The direction of the cable hole on back panel is pointing down. 6 B. With 4 TA5*40mm screws, tighten the back panel on the wall as diagram (6). C. Connect the cables of RJ45, power, and electric-lock to the motherboard socket as mentioned in connectors description (refer to Section 2). D. Test whether there is electricity by doing the following: Press the # button for 3 seconds to get the IP address of intercom by voice. Input access password or press the indoor switch to check electric-lock installation. Note: Do not proceed mounting until you have finished the electric checking. Step 4: Mounting Figure 8 Figure 9 A. sponges is loaded into a screw hole. As shown in Fig. 8, the rear shell is locked. should not be ignored! B. Push the front panel into the plastic frame, and tighten it with 6 screws as diagram (9). Note: Make sure the screws have been tightened properly for better waterproof effect. 7 4. Searching Door Phone There are two methods as shown below to search the device. Method 1: Open the iDoorPhone Network Scanner. Press the Refresh button to search the device and find the IP address. Method 2: Press and hold the "#" key for 3 seconds and the door phone will report the IP address by voice. In addition device provides the device surface DSS key operation to switch IP address acquisition mode: long press the DSS key for 10 seconds, to be issued by the speaker Beep, and then press the DSS key three times, the beep stops. Wait 10 seconds, after the success of the system automatically broadcast the current IP address. Default DHCP Client Static IP Address Default Web Port Default Login User Name Default Login Password Display IP address Search Tools Default Setting Enable 192.168.1.128 80 admin admin Hold # for 3 seconds to display by voice iDoorPhone Network Scanner 8 5. SIP Door Phone Setting Step 1: Log in the door phone Input IP address (e.g. http://192.168.1.149) into address bar of PC's web browser. The default user name and password are both admin. Step 2: Add the SIP account. Set SIP server address, port, user name, password and SIP user with assigned SIP account parameters. Select "Activate", and then click Apply to save this setting. Step 3: Setting DSS key Set the DSS key as shown below for a quick start. Click "Apply" to save this setting. Type: Hot Key Number 1: The DSS Key will dial to this Number 1. Number 2: If Number 1 is unavailable, it will be forwarded to Number 2. Line: Working line Subtype: Speed dial 9 Step 4: Door Phone Setting 6. Door Unlocking Setting Local 1) Local Password Step 1: Go to EGS Setting Features Set Local Password (The default is "6789"). Step 2: Use the device's Numeric Keyboard to input password and "#" key, and then the door will be unlocked. 10 2) Private Access Code Step 1: Go to EGS Access Access Rule set Access Code. Step 2: Use the device's Numeric Keyboard to input password and "#" key, and then the door will be unlocked. Remote Remote Password Step 1: Go to EGS Setting Features Set Remote Password (The default is "*"). Step 2: To answer the call made by visitor via SIP phone, press the "*" key to unlock the door the visitor. - RFID Card Step 1: Go to EGS Access Enter the Name and ID Number (Only Front 10 yards) Press Add to Access Table. Step 2: Use pre assigned RFID cards to unlock the door by touching RFID area of device. 11