Installation Guide for Altronix models including: T2ZK7F8 8 Door Kit with Fused Outputs, T2ZK7F8, 8 Door Kit with Fused Outputs, Fused Outputs
Altronix T2ZK7F8 | 8-Door Access and Power Integration Kit
File Info : application/pdf, 8 Pages, 1.11MB
DocumentDocumentAccess & Power Integration Altronix/ZKTeco Kits Models Include: T2ZK7F8 8 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TZ2 Altronix/ZKTeco backplane - One (1) eFlow104NB - Power Supply/Charger - One (1) ACM8 - Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module T2ZK7F16 16 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TZ2 Altronix/ZKTeco backplane - One (1) eFlow104NB - Power Supply/Charger - Two (2) ACM8 - Access Power Controllers - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module All components of this Trove kit are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information. Installation Guide All registered trademarks are property of their respective owners. Rev. TZK_041019 More than just power.TM Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix T2ZK7F8 and T2ZK7F16 Trove ZKTeco kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and sub-assemblies. T2ZK7F8 accommodates up to two (2) ZKTeco modules for up to eight (8) doors in a single enclosure. T2ZK7F16 accommodates up to four (4) ZKTeco modules for up to sixteen (16) doors in a single enclosure. Configuration Chart: 120VAC 60Hz Input Current (A) Power Supply Board Input Fuse Rating Power Supply Board Battery Fuse Rating Fail-Safe/Fail-Secure or Dry Form "C" Outputs Additional Fused Outputs ACM8 Board Input Fuse Rating ACM8 Board Output Fuse Rating PDS8 Board Input Fuse Rating PDS8 Board Output Fuse Rating Altronix Model Number T2ZK7F8 T2ZK7F16 Maximum Supply Current for Main and Aux. Outputs on Power Supply board and ACM8 Access Power Controllers' outputs Nominal DC Output Voltage [DC] [Aux] Output Range (VDC) Output Range (VDC) 4.5 6.3A/ 15A/ 250V 32V 24VDC @ 9.7A 24VDC @ 9.4A 8 20.17-26.4 20.28-26.4 16 8 10A/ 2.5A/ 10A/ 3A/ 250V 250V 32V 32V Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two/three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the two/three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure Fig. 1 approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. Enclosure 4. Mount ZKTeco modules to backplane, refer to pages 3 - 6. 5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NB and Edge of Enclosure corresponding Sub-Assembly Installation Guides for ACM8, PDS8 and VR6 for further installation instructions. Tamper Switch (included) Hardware: Nylon Spacer | 5/16" Pan Head Screw | Lock Nut To Access Control Panel or UL Listed Reporting Device - 2 - Trove ZKTeco Kits Installation Guide T2ZK7F8: Configuration of ZKTeco inBio Modules: 1. Fasten DIN Rail (provided by ZKTeco) to pem spacers, utilizing 5/16" pan head screws (included) (Fig. 2, pg. 3). 2. Mount ZKTeco modules to DIN Rail (refer to below chart for model number, Fig. 2, pg. 3). 3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (provided by Altronix). ZKTeco Model inBio-160, inBio-160 Pro, inBio-260, inBio-260 Pro, inBio-460, inBio-460 Pro Fig. 2 Pem Mounting A DC + A BAT + Altronix - eFlow104NB L G N INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 A -+-+ Power Control Altronix - PDS8 DM1 + OFF IN1 IN2 IN1 Fuse 10 DM1 + 10 3 3 3 3 3 3 3 3 Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P Common (--- ) OUT1 DM2 + N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 Common (--- ) DM2 + Altronix VR6 is mounted under PDS8 A A Trove ZKTeco Kits Installation Guide - 3 - T2ZK7F8: Configuration of ZKTeco C3 Modules: 1. Fasten spacers (provided) to pems that match the hole pattern for ZKTeco boards. Refer to below chart for model number and Fig. 3, pg. 4. 2. Mount ZKTeco boards to spacers utilizing 5/16" pan head screws (included) (Fig. 3a, pg. 4). 3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (included). ZKTeco Model C3-400, C3-400 Pro C3-100, C3-100 Pro, C3-200, C3-200 Pro Fig. 3 Pem Mounting B C DC + Altronix - eFlow104NB L G N BAT + BC INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 B C -+-+ Power Control Altronix - PDS8 DM1 + OFF IN1 IN2 IN1 Fuse 10 DM1 + 10 3 3 3 3 3 3 3 3 Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P Common (--- ) OUT1 DM2 + N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 Common (--- ) DM2 + Altronix VR6 is mounted under PDS8 BC BC - 4 - Fig. 3a Pem Spacer Pan Head Screw ZKTeco C3 100/200/400 Backplane Trove ZKTeco Kits Installation Guide T2ZK7F16: Configuration of ZKTeco inBio Modules: 1. Fasten DIN Rail (provided by ZKTeco) to pem spacers, utilizing 5/16" pan head screws (included) (Fig. 4, pg. 5). 2. Mount ZKTeco modules to DIN Rail (refer to below chart for model number, Fig. 4, pg. 5). 3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (provided by Altronix). ZKTeco Model inBio-160, inBio-160 Pro, inBio-260, inBio-260 Pro, inBio-460, inBio-460 Pro Fig. 4 Pem Mounting A DC + A BAT + Altronix - eFlow104NB L G N INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 A -+-+ Power Control INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 A -+-+ Power Control DM1 + OFF IN1 IN2 10 3 Altronix - PDS8 IN1 Fuse 10 DM1 + 3 3 3 3 3 3 3 Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P Common (--- ) OUT1 DM2 + N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 Common (--- ) DM2 + Altronix VR6 is mounted under PDS8 A Trove ZKTeco Kits Installation Guide - 5 - T2ZK7F16: Configuration of ZKTeco C3 Modules: 1. Fasten spacers (provided) to pems that match the hole pattern for ZKTeco boards. (refer to below chart for model number, Fig. 5, pg. 6). 2. Mount ZKTeco boards to spacers utilizing 5/16" pan head screws (included) (Fig. 5a, pg. 6). 3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (included). ZKTeco Model C3-400, C3-400 Pro C3-100, C3-100 Pro, C3-200, C3-200 Pro Fig. 5 Pem Mounting B C DC + Altronix - eFlow104NB L G N BAT + BC INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 BC -+-+ Power Control INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 BC -+-+ Power Control PWR1 + OFF IN1 IN2 10 3 Altronix - PDS8 IN1 Fuse 10 DM1 + 3 3 3 3 3 3 3 Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P COM --PWR2 + OUT1 N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 COM --PWR2 + Altronix VR6 is mounted under PDS8 BC - 6 - Fig. 5a Pem Spacer Pan Head Screw ZKTeco C3 100/200/400 Backplane Trove ZKTeco Kits Installation Guide eFlow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network... LINQ2 - Network Communication Module LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up, minimizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR). LINQ2 Features: - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature. - Access control and user managment: Restrict read/write, Restrict users to specific resources - Two (2) integral network controlled Form "C" Relays. - Three (3) programmable input triggers: Control relays and power supplies via external hardware sources. - Email and Windows Dashboard notifications - Event log tracks history. - Secure Socket Layer (SSL). - Programmable via USB or web browser - includes operating software and 6 ft. USB cable. LINQ2 Mounts Inside any Trove Enclosure LINQ2 Module Network Connection: Installation, Programming and Monitoring Altronix eFlow Power Supply Trove ZKTeco Kits Installation Guide - 7 - 2.00" (50.8mm) 1.25" (31.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 1.5" (38.1mm) Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm) 21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm) 2.00" (50.8mm) 6.25" (158.8mm) 0.5625" (14.3mm) 0.685" (17.4mm) 1.77" (45mm) Knockouts 1.125" (28.3mm) 2.415" (61.3mm) 0.885" (22.5mm) 19.80" (502.9mm) 2.00" (50.8mm) 6.75" (171.5mm) 8.25" (209.5mm) 27" (685.8mm) 8.00" (203.2mm) 1.00" (25.4mm) 0.85" (21.6mm) 1.25" (31.8mm) 2.00" (50.8mm) 2.00" (50.8mm) 5.25" (133.4mm) 7.00" (177.8mm) 5.25" (133.4mm) 1.25" (31.8mm) 2.00" (50.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITrove ZKTeco Kits J22U MEMBER - 8 - Trove ZKTeco Kits Installation Guide