Installation Guide for WORCESTER models including: Greenstar KE Heat Interface Unit, Greenstar KE, Heat Interface Unit, Interface Unit, Unit

Worcester Greenstar Heat Interface Unit (HIU) User Manual

Worcester, Greenstar, Heat, Interface, Unit, (HIU), User, Manual

www.plumbnation.co.uk

Worcester Greenstar Heat Interface Unit (HIU) User Manual

29 mag 2024 — All models are insulated with EPP on the front and rear of the appliance. worcester-bosch.co.uk/heat-networks 5. Page 6. Under ...

29 mag 2024 — The Greenstar HIU is perfect for both small and large scale district heating solutions. This includes flats and other multi-residential accommodation, ...12 pagine


File Info : application/pdf, 12 Pages, 2.58MB

PDF preview unavailable. Download the PDF instead.

worcester-greenstar-heat-interface-unit-hiu-user-manual ?srsltid=AfmBOor6aWKXbRkSM7OJEBgO1YxSGnXAUJg2ZFZEB4uazwLD1rAZQLDN
Greenstar Heat Interface Units
An overview guide on our BESA registered Greenstar KE and E range.

Installer guide

Meet the next generation Heat Interface Unit (HIU)

Designed with the future in mind
The new Greenstar HIU is part of a market-leading range of innovative energy-saving heating and hot water solutions from Bosch Thermotechnology Ltd.
The Greenstar HIU provides domestic hot water and space heating to properties that are serviced from district heating or centralised boiler plants, and is fully compatible with the Bosch Commercial and Industrial product range.

Designed to meet the latest and future market requirements, the new Greenstar HIU includes a top-of-the-range appliance that offers 21 litres per minute flow rate and incorporates components such as a differential pressure reducing valve.

The Greenstar HIU

Innovative design User-feedback Accurate control Bosch quality

Manufactured in the UK
2 Worcester Bosch HIU

Call our design team: 0330 123 3004

District heating on any scale

Small and large scale solutions
The Greenstar HIU is perfect for both small and large scale district heating solutions. This includes flats and other multi-residential accommodation, as well as buildings that use uneconomical electric heating, or have individual gas appliances in each property.
A centralised heating concept allows investors to take full advantage of a low carbon heat source or a modular/hybrid configuration with high efficiency condensing boilers.
The Greenstar HIU is also compatible with Bosch Commercial and Industrial products for both new and existing multi-purpose and multi-residential buildings, as well as large estates that include commercial units.

Custom solutions...
from Europe's market leader in heating and hot water systems.
District Heating Design Team
Turn to page 11 to learn about how our team can design the complete system for your new build,

worcester-bosch.co.uk/heat-networks 3

All the properties contractors look for

 Separate first fix rail pipe work jig
 Top and bottom connections with optional pre-made pipe work kit
 Insulation as standard
 Pre-set adjustable ERP pump with inbuilt pump kick
 Flushing bypass and security fixings available as accessory
 Inbuilt filter and DHW temperature limiter
 Mbus meter connection point
 In built pre-payment function ­ no need for external valves
 Keyless filling link available as an accessory
 Easy to install with in-line compression fittings, or with 3/4"MBSP fittings on the district connections, and can be installed in a small area

 Weighs 33kg*
 A DHW valve prioritises the temperature at the DHW heat exchanger for maximum comfort
 Controlled water temperature in the heat exchanger reduces the risk of limescale formation
 Supplied with or without heat meter to suit specific requirements
 At our training academy, we can test your specific design parameters against our HIUs, while demonstrating its performance
 Bosch employed and trained engineers providing national coverage
 Quick on-site engineer response time
 Contact centre open 364 days a year.

*Without cover and first fix rail.

4 Worcester Bosch HIU

Email enquiry: commercial.industrial@uk.bosch.com

Delivering for investors
 The automatic control of the return temperature maintains the district heating scheme requirement for low return temperatures
 High differential pressure tolerance of 800mbar (without DPCV) and up to 4000mbar (with DPVC)
 Adjustable secondary flow temperatures for low temperature heating
 Maximum heating and DHW temperatures set by the commissioning engineer
 Low return temperature in the primary circuit maximises efficiency in the system, saving energy
 Internal insulation standard on all models
 Models with heat meters for measurement of heat energy used in individual properties.

Simple adjustment and setting of DHW and CH which can be fixed at commissioning or controlled by a compatible controller.

All models are insulated with EPP on the front and rear of the appliance.

Heat meter.
worcester-bosch.co.uk/heat-networks 5

Under the cover Greenstar HIU KE
Control unit
DHW control valve Manual air vent (DHW)
Plate heat exchanger (DHW) Expansion vessel

District heating supply sensor (hidden)
DHW outlet sensor NTC
Expansion vessel connection point
DHW pressure relief valve
Flow turbine and flow regulator DHW Safety/
Anti scald Valve (Partially hidden)
Heat meter flow sensor connection
point (hidden)
Filter and drain point (district heating)

Cold mains inlet connection

Domestic District

Hot

heating

Water

supply

connection connection

District

Central

heating heating flow

return connection

connection

Central heating control valve Return sensor NTC (district heating) Manual air vent (central heating) Manual air vent (district heating)
Plate heat exchanger (central heating)
Differential pressure control valve (if fitted)
Flow sensor NTC (central heating)
Heat meter (if fitted) Central heating circulating pump Bypass valve accessory (if fitted) Drain point (central heating flow) Drain point (central heating return) Central heating return connection
Pressure relief valve (central heating)

6 Worcester Bosch HIU

Call our design team: 0330 123 3004

Dimensions and clearances

Dimensions and hydraulic connections

440

270

37

127

263

50

582 700

19 18

18 390

79 65 65 65 65 65 123456

81 40 7

Key

Description

Connection (mm)

1

Cold mains inlet

22

2

Domestic Hot Water outlet 22

3

District heating supply

22

4

District heating return

22

5

Central heating flow

22

6

Central heating return

22

7

Pressure relief valve

15

Minimum installation and maintenance clearances

Key

Description

Dimensions (mm)

1

Overall clearance height

930

2

Overall clearance depth

870

3

In front of appliance

600

4

Overall clearance width

450

5

Above the appliance

30

6

Either side of appliance

5

7

Below the appliance

200

4

5

2

3

6 6

1

7

Minimum compartment clearances

2

6

7

3

1 4

4 5

Key

Description

1

Compartment height

Dimensions (mm) 930

2

Compartment width

450

3

Above the appliance

30

4

Either side of appliance

5

5

Below the appliance

200

6

Compartment depth

290

7

Appliance to removable door 20

worcester-bosch.co.uk/heat-networks 7

Internal schematic

1 2

16

3

15

4

5

14 6

13

7

12

8

11

10

9

Key

Description

1

Control unit

2

Return sensor NTC (district heating)

3

Central heating plate heat exchanger

4

Central heating control valve

5

Differential pressure control valve (if fitted)

6

Flow sensor NTC (central heating)

7

Heat meter (if fitted)

8

Circulating pump

9

Heat meter flow sensor connection point

10

Supply sensor NTC (district heating)

8 Worcester Bosch HIU

Key

Description

11

Domestic Hot Water safety valve

12

Flow turbine

13

Flow regulator

14

Domestic Hot Water outlet sensor NTC

15

Domestic Hot Water control valve

16

Domestic Hot Water plate heat exchanger

Email enquiry: commercial.industrial@uk.bosch.com

Technical data
General Information
Height Width Depth Total unit weight (lift weight) Packaged unit weight Maximum output to domestic hot water 1) Output range to central heating Maximum flow temperature secondary heating Maximum flow temperature DHW District heating flow and return connections (compression) District heating flow and return connections (flat faced) Secondary heating flow and return connections (compression) Cold feed and DHW connections (compression) Pressure relief valve connection Maximum working pressure district heating side Pressure relief valve setting secondary heating side Maximum working pressure domestic hot water side pH value (district water supply), approximate Expansion vessel Expansion vessel charge District Temperature (80ºC) Primary flow rate Primary return temperature Primary pressure drop DHW output (50°C) DHW flow rate (50°C) District Temperature (70ºC) Primary flow rate Primary return temperature Primary pressure drop (including heat meter) DHW output (50°C) DHW flow rate (50°C) District Temperature (60ºC) Primary flow rate Primary return temperature Primary pressure drop DHW output (50°C) DHW flow rate (50°C) Electrical Electrical power supply voltage Frequency Maximum power consumption Standby power consumption Appliance protection rating
1) Nominal output at 90°C primary and 60°C DHW. 2) Sized for up to 15kW radiator systems.

Units
mm mm mm kg kg kW kW ºC ºC mm inch mm mm mm bar bar bar
l bar
l/s ºC kPa kW l/min
l/s ºC kPa kW l/min
l/s °C kPa kW l/min
AC...V Hz W W IP

Greenstar HIU KE with Heat Meter 700 440 270 33 36 72.7 1-15 80 60 22 3/4"MBSP 22 22 15 10 3 10 7-9 5 0.75

Greenstar HIU E with Heat Meter 700 440 270 31 34 51.4 1-15 80 60 22 3/4"MBSP 22 22 15 10 3 10 7-9 5 0.75

0.225 17.7 20.0 58.6 21

0.153 19.0 11.5 39.1 15

0.213 22.7 40.4 41.3 15

0.18 25 29.8 33 12

0.248 27.6 54.6 33 12

0.2 29.8 36.4 24.8 9

230 50 41.3 3.1 40

230 50 41.3 3.1 40

worcester-bosch.co.uk/heat-networks 9

End users enjoy accurate control and responsive heating to achieve the desired comfort levels.

Features of the Greenstar HIU range

Greenstar KE 21 litres/min flow rate Electronically controlled internal valve Integral pressure balancing valve (DPCV) as standard Ability to remotely isolate unit (with heat metering partner) Summer bypass as accessory Customer access to heat meter data Ability to fit anti-tamper screws to the casing Insulation on internal components 10 bar district heating pressure Ability to run pipes behind unit Modulating pump System flushing valve as accessory

Greenstar E 15 litres/min flow rate Electronically controlled internal valve Integral pressure balancing valve (DPCV) as accessory Ability to remotely isolate unit (with heat metering partner) Summer bypass as accessory Customer access to heat meter data Ability to fit anti-tamper screws to the casing Insulation on internal components 10 bar district heating pressure Ability to run pipes behind unit Modulating pump System flushing valve as accessory

All Greenstar HIU options are available in two versions, with or without a heat meter.
*Our KE and E models are BESA registered.

10 Worcester Bosch HIU

Call our design team: 0330 123 3004

District heating design services
Whether designing a new build, retrofit or deep renovation heat network, our expert consultants are here to help you fully design and configure the perfect system ­ from plant room to HIU and everything inbetween. Speak to your local Bosch Commercial and Industrial contact to arrange a visit to our training academy. Here we can test specific design parameters against our HIUs, while demonstrating its performance for your specific project.  Supporting designs in accordance with
CIBSE CP1 2020  Ensure minimal heat loss and low return
temperatures  Correct sizing of plant and network  Layouts on 3D drawing (including plant
room schematics/riser schematics)  BIM level 2 covering entire product range  System and product configuration  Design and schematic reviews  Dedicated Bosch consultant assigned to you  District Heating CPD available.
For more information or to discuss a project, please call our design team on 0330 123 3004, or email us at: commercial.industrial@uk.bosch.com

Did you know? You can also book a free design consultation at bosch-industrial.co.uk/ district-heating

worcester-bosch.co.uk/heat-networks 11

Useful numbers
Sales Tel: 0330 608 8456 Email: sales.bosch@uk.bosch.com
Technical Helpline (Pre & Post Sales) Tel: 0330 123 0165 Email: technical-advice@uk.bosch.com
Spare Parts Email: spares.mailbox@uk.bosch.com or telephone 0330 123 9779
Controls Helpline Tel: 0330 123 3641
Training Email: training@uk.bosch.com or telephone 0330 123 0166 Book a course online at worcester-bosch.co.uk/eacademy
Share
We would love to see your installations!
Worcester Bosch Professional @WorcesterBoschProfessional @WorcesterBosch Worcester Bosch Worcester Bosch Group
Worcester Bosch Cotswold Way Warndon Worcester WR4 9SW worcester-bosch.co.uk
Calls to and from Bosch Thermotechnology Ltd may be recorded for training and quality assurance purposes. This brochure is accurate at the date of printing, but may be superseded and should be disregarded if specification and/or appearances are changed in the interest of continued improvement. The statutory rights of the consumer are not affected. 8 716 121 984 Issue B 01/23



References