ICE BATH MAX PRO CHILLER/HEATER

USER MANUAL

COOLS FILTER OPTIMAL
AND HEATS B U I L T I N R E C O V E R Y

ICE BATH MAX CHILLER/HEATER
What's in the Box
1 x Legacy Recovery Ice Bath MAX PRO Chiller/Heater Unit 2 x External Hoses 4 x Brass Fittings 4 x Hose Fasteners 4 x Wheels 1 x 20-Micron Filter + Plastic Wrench 1 x Instruction Manual
Customer Support
If you are having any trouble setting up your unit, please feel free to contact us at support@legacyhealthstore.com

WARNING!

ELECTRICITY IS VERY DANGEROUS, IN ORDER TO PREVENT ACCIDENTS
OR DEATH PLEASE PAY ATTENTION TO SAFETY AND ENSURE YOU FULLY READ THIS INSTRUCTION MANUAL BEFORE USE.

1. During and after transportation, the Legacy MAX PRO Chiller/Heater Unit must stay upright on a stable surface at all times.

2. After transportation, and before use, the chiller must be left for 24hrs for the refrigeration gas to settle.

3. Make sure there are no water leaks from the Legacy MAX PRO Chiller/Heater Unit, or inlet and outlet pipes when connected to the Ice Bath MAX, with at least 12'' between the chiller and the wall for proper air flow.

4. Make sure the Legacy MAX Chiller/Heater Unit is plugged into an AC socket or extension cable that is suitable for use, properly grounded, has a built in surge protector and preferably is IP65 rated.

5. Ensure the Legacy MAX PRO Chiller/Heater Unit is kept dry at all times, do not immerse, splash or spray the unit with water. If the unit does get wet, unplug it immediately and do not use.

6. Never leave the Legacy MAX PRO Chiller/Heater Unit switched on when using the Ice Bath MAX, always ensure the unit is switched off during your cold water therapy session.

7. If the Legacy MAX PRO Chiller/Heater Unit stops working or doesn't work when switched on, unplug it immediately and do not use.

8. We accept no responsibility for misuse or failure to use this equipment safely as

instructed.

1

Safety and Usage Notes
1. Before using your Ice Bath MAX Chiller/Heater unit, please read this instruction manual carefully.
2. Never install the unit in a closed room with limited air volume or close to shrubbery that might block the air inlet. Such locations impair the continuous supply of fresh air, may reduce the running efficiency and possibly prevent sufficient heat output.
3. Never clean your MAX PRO Chiller/Heater unit with strong bleach-based detergents.
4. To empty your MAX PRO Chiller/Heater unit, use the drain tap located near the bottom of the unit. Take care with the drain tap, don't force it and make sure it is fully closed after use.
5. Though not essential, to ensure a long service life and for hygiene purposes, we recommend draining, cleaning and drying your Chiller/Heater unit every two to three weeks.
6. Before connecting the machine, make sure that the supply voltage matches the operating machine's voltage. There's RCD plug that equipped with power cable; it helps to offer a full electrical protection.

Always make sure the power plug is secured. If the plug is not

secure, it may cause an electric shock, over-heating or fire

2

Quick Start Guide

ICE BATH MAX CHILLER/HEATER

Ice Bath MAX Chiller/Heater Initial Set Up
1. Install the 4 wheels on the bottom of the chiller/heater unit. 2. Place the plastic drainage tube on the bottom of the chiller/heater unit. This will allow
you to drain/ clean the water in the chiller/heater when needed. It will also allow any condensation to drain from the unit. 3. Use the plastic wrench tool to unscrew the filter bottle. Place the included micron filter into the filter bottle and fill with water to the line. Cap the bottle and use the plastic wrench tool to fasten the filter bottle until tight. Check for any water leakage before preceding to the next step. 4. Screw in two of the brass fittings into the water outlet and inlet of the chiller/heater unit. Check to make sure they are hand tight.

Please ensure the filter is pre-filled with water before starting each

time, or the pump will not work

3

Quick Start Guide

ICE BATH MAX CHILLER/HEATER

Connecting Your Chiller/Heater with your Ice Bath MAX (1/2)
1. Ensure you have assembled your Legacy Ice Bath MAX first before continuing.
2. Place the Chiller/Heater Unit on a stable surface with at least 12'' between the chiller/heater and the wall for proper air flow.
3. Screw in the remaining 2 brass fittings into the outlet and inlet ports of the Legacy Ice Bath MAX.
4.Place 2 hose fasteners at the end of each hose. 5.Connect the Inlet pipe from the Legacy MAX Chiller/Heater Unit to the Out
port of the Ice Bath MAX and Outlet pipe from the Chiller/Heater Unit to the In port of the tub. Tighten the fasteners until the brass fittings are firmly connected to the hoses. They should not be able to be easily pulled apart.

4

Quick Start Guide

ICE BATH MAX CHILLER/HEATER

Connecting Your Chiller/Heater with your Ice Bath MAX (2/2)

1.You can now fill your Ice Bath MAX with 'cold water' using a hose until the water is roughly 15 cm (6 inches) below the underside of the top ring (not more than  full). Make sure the water level is above the top inlet of the Ice Bath MAX.
2.Plug in and switch on the chiller. Check for leakage and verify that water is flowing incoming and outgoing to the ice bath tub.(Please see page 10 if you encounter problems)
3.Press the `run' key on the control panel. The machine will start up setting the target temperature. After a few minutes, check whether the air blowing out of the unit is hot. If it is, it means it to working correctly.
4.Once the chiller has finished its priming cycle it will start to chill and filter the water within a few minutes.
5.It can take up to 3-4hrs to chill the water from 65°F down to a frosty 37°C. 6.Once the desired temperature is reached, switch off the Chiller/Heater Unit
before starting your cold water therapy session.

Operation Guide
Control Panel Interface
11

Operation Guide
Key Press Functions
1. Auto Indicator Light: a.On- System is auto regulating temperature b. Off- System is not auto regulating temperature
2. Cooling Indicator Light: a.On- System is cooling b. Off- System is not cooling
3. Heating Indicator Light: a.On- System is heating b. Off- System is not heating
4. Defrost Indicator Light: a.On- System is defrosting b. Off- System is not defrosting
5. Fault Indicator Light: a.On- System is out of order b.Off- System is working normally
6.Wifi Connection a.On- Unit is connected to Wifi b.Off- Unit is not connected to Wifi
7.Funtion Key a.tap the "Function" key to switch between heating - auto - & cooling mode.
8.Timing Key a.Use this key to set the time the unit runs
9.Run Key a.Press once to stop or turn on the machine
10.Up Key a.Used to adjust parameters upward
11.Down Key a.Used to adjust parameters downward

Operation Guide
Key Press Functions
Setting the Time on the Unit 1.On the home screen, hold down the "Timing" key for 5 seconds to enter the real-time clock setting screen. The clock hour and minute will blink together. 2.In the real-time clock setting screen, press the "Timing" key again. When the number of the hour part flashes and the minute part stops blinking, you can press the "+" key or "-" key to set the hour of the real-time clock. 3.When the hour part is set, press the "timing" key again. The number of the minute part will flash, and the hour part will stop blinking. At this time press the "+" key or "-" key to set the minute of the real-time clock. 4.When the minute is set, press the "timing" key again, confirm the time, and return to the main interface. 5.In the real-time clock setting interface, if no key operation is performed for 30 consecutive seconds, the current real-time clock setting value is confirmed and the home screen is returned.
Scheduling the Unit to Run Automatically 1.On the home screen, tap the Timing key to enter the setting screen. 2.When you enter the timing setting screen, timing group 1 will be blinking. The controller has 1 and 2 timing groups. 3.When segment 1 is blinking, press the Timing key to enter the screen for setting the hour part of the timed startup time for group 1. When the number of the hour part of the timed startup time is blinking, press + or - to set the hour part of the timed startup time for group 1. 4.When the hour part of timed startup is set, press the "timing" key again, then the number of the minute part of timed startup time is blinking. At this time, press the "+" key or "-" key, then you can set the minute of timed startup time for group 1. 5.When the timing group 1 group is set, then press the "timing" key again. Then enter the hours the unit will be scheduled to shut down, using the same method as above. When the timing shutdown time is set, press the "timing" key again to save the settings.

Common Problems with Initial Set Up
When you first start using the unit, please pay attention to the water level in the bathtub and the relative position of the filter. There might be strange noises coming from the machine and the water circulation may not run properly. This is due to the presence of air in the water pipes that need to be
expelled. If you encounter this issue, please use this solution to resolve the problem. .

1. When the water level in the ice bucket is lower than the height of the machine's water inlet, the water

cannot flow into the machine.

2.

Fill the ICE BATH MAX with enough water to exceed the height of the machine's water inlet.

3. Slightly loosen the filter bottle to create a gap for air to escape. Turn on the machine, allowing water to enter the filter, and air to be pushed out
through the gap.

4. Once the water out let flow is sufficient, the machine will operate normally. You can then retighten the filter bottle and the lid.
The initial air purging process can take up to 5 minutes

10

Common Problems with Initial Set Up
Try the following if the initial air purging process does not work.
a. Solution 2: Power off the chiller/heater. Place a hose into the tub at the lower tub inlet. The head of the hose and the inlet should be `connected'. Turn on the hose and run the water through the tubes. Continue this process until you see bubbles air come out of the upper inlet tube into the tube. Run the hose like this for 5 minutes and retest.
b. Solution 3: Turn off the unit. Remove the filter and run the unit. If the unit starts to run correctly, replace the filter and run it again.

Fault Code Analysis and Solutions
Fault: If a fault occurs then an error code will be shown; A serious fault which stops the operation of the unit will be accompanied by an alarm sound, along with an error code.

Error Code

Reason

Error Code

Reason

E1

Exhaust temperature fault

P11

High exhaust temperature protection

E5

The temperature of the coil is faulty

E9

The return temperature is faulty

E18

Outlet temperature fault

E19

Inlet temperature fault

E21

The communication with the indoor unit fails

E22

Ambient temperature fault

P01

Water flow switch fault

P15

Inlet and outlet water temperature difference is too large protection

P16

Refrigeration undercooling protection

P17

Standby anti-freezing protection

P25

Ring temperature protection

P26

The heating water temperature is too high

P27

Cooling outer coil overtemperature protection

P02

High voltage protection

P06

Low pressure protection

Cold Therapy Recommended Time Protocols
Cold water therapy works best with the right combination of time and temperature. For example, if you are in water with a temperature of 10°C, we would recommend you stay for no more than 10mins
Temperature to Time examples: 1°C = 1 minute submersion 2°C = 2 minutes submersion 3°C = 3 minutes submersion 5°C = 5 minutes submersion 10°C = 10 minutes submersion 15°C = 15 minutes submersion

ICE BATH MAX CHILLER/HEATER
Product Specifications
Dimensions
34kg weight 63(W) x 40(D) x 42(H)cm 110-120V AC input 2600W cooling/2750W heating
Specifications
Portable 'all-in-one' contained unit Ozone sanitation built in Self-priming circulation pump Washable high-density particle water filter Cools water down to 2°C (35.6°F) Heats the water up to 40°C (104°F) Minimum working temperature -5°C (23°F)