User Manual for Philio models including: PAN34, In-Wall Roller Shutter Controller

In Wall Roller shutter controller PAN34

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push ...

Philio PAN34-US

Manufacturer Manual

Philio PAN34-RU


File Info : application/pdf, 13 Pages, 398.04KB

PDF preview unavailable. Download the PDF instead.

PAN34 manual-20210728
In Wall Roller shutter controller PAN34

other security enabled Z-Wave Plus products. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with this device regardless of the manufacturer. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturer. Within the network it will act as repeater regardless of vender to increase reliability of the network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration. This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all functions. Its functionality and supported command classes is identical when included as a secure and non-secure device. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter. This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method, so it can be remote controlled not only fully up or down, but also can be adjusted to ex. 30% or 50%. And when manual controlled by push button, the controller also can memorize the position and send the new shutter position to its controller (ex. IP-Gateway).

Safety Precautions and Installation

 Avoid installing the unit in storming or raining weather.

Introduction

 Be sure to isolate or switch off power source before installing or maintenance.

 Do ensure that the power supply circuit protected by a 16A circuit breaker or

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter

suitable equivalent fuse.

connected to its terminals using radio waves, controllers and a push button directly

connected to this Roller Controller.

IMPORTANT

This in-wall Roller Shutter Controller is a Z-Wave PlusTM enabled wireless device fully

compatible with any Z-WaveTM enabled networks. This device is a security enabled Z-

 Installation must be performed by skilled technicians who are informed about

Wave Plus product that uses encrypted Z-Wave Plus messages to communicate to 1

the standards and technical requirements of the appliance and its proper

installation.  Check your local codes as they apply to your situation. If the house wiring is of
aluminum, consult with an electrician about proper wiring methods.  Before proceeding with the installation, TURN OFF THE POWER TO THE
LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK.

Specification

Operating Voltage Maximum Load Range Operating Temperature Humidity Storage Temperature Location Frequency Range
RF Maximum Power Communication Protocol OTA FCC ID Dimensions Wire

100 -240VAC 50-60Hz Resistive load 5A max. Minimum 40 m in door 100m outdoor line of sight 0°C - 40°C Up to 85% max. -20°C to 60°C Indoor use only 868.40MHz; 869.85MHz (EU) 908.40MHz; 916.00MHz (USA/Canada) 920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan) +10dBm (Peak), -10dBm (Average) Z-WaveTM Yes RHHPAN34 47.5 x 39 x16 mm 0.75mm², 18AWG

** Specifications are subject to change and improvement without notice.

Troubleshooting

Symptom

Cause of Failure

Recommendation

The PAN34 not working 1. The PAN34 is not

1. Check power connections

and LED off

connect to the Main 2. Don't open up the PAN34 and send

power

it for repair.

2. The PAN34 break

down

The shutter move direction Wrong connection of NC Swap the NC NO connection

is reverse
PAN34 LED light work fine But can not control

and NO to the motor
1. No association setting 2. Same frequency
interference 3. S1 or S2 are both
pressed in Two Push Button switch type, PAN34 would not accept RF command.

1. Carry out association 2. Wait for a while to re-try 3. Release S1 and S2

2

Fig 1. Assembling Installation and operation
1. Put the in wall PAN34 into a wall box and connect the AC power wire L,N to PAN34 connector L, N.
2. Connect the wall switch to the PAN34 as Fig1 3. To manually switch up and down of the shutter, simply press the external switch S1
or S2. The detail is described in 7-5. 4. PAN34 built in meter function and can read the Watt, KWh, V(Voltage), I(Current),
PF (Power Factor) of the load by using Z-Wave command class, user can set a threshold current to get the warning caused by abnormal operation 5. PAN34 have overload protection function and can help to prevent short circuit caused by load.

Adding to Z-WaveTM Network
In the front casing, there is an include button with LED indicator below which is used to carry out inclusion, exclusion, reset.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/reset devices.

DANGER Danger of electrocution!
All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations. Any works introducing changes into the configuration must be always performed with disconnected voltage. Choosing a Suitable Location 1. Do not locate the Module facing direct sunlight, humid or dusty place. 2. The suitable ambient temperature for the Module is 0°C~40°C. 3. Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc. 4. After putting it into use, the body of Module will become a little bit hot of which phenomenon is normal.

Function No node ID

3

Description

LED Indication

The Z-Wave Controller does not allocate LED 2-second on, 2-second

a node ID to the PAN34.

off

Add (Classic Inclusion) SmartStart
Remove

1. Put your Z-Wave controller into

One press one flash LED

inclusion mode by following the

instructions provided by the

controller manufacturer.

2. Pressing Include button three times

within 2 seconds will enter inclusion

mode.

1. The product has a DSK string. Key

in the first five digits to initiate the

SmartStart process, or scan QR

code.

Ex: DSK: 18112-24021- 48001-

62259-57092-27453-08187-47408

2. SmartStart enabled products can

be added into a Z-WaveTM network

by scanning the Z-WaveTM QR

Code on the product, with a

controller providing SmartStart

inclusion. No further action is

required and the SmartStart product

will be added automatically to the

closest network within 10 minutes of

being switched on.

Notice:

The QR Code can be found on the

device PAN34 or in the box.

1. Put your Z-Wave controller into

One press one flash LED

(Exclusion)

exclusion mode by following the

instructions provided by the

controller manufacturer.

2. Pressing Include button three

times within 2 seconds will enter

exclusion mode.

Node ID has been excluded.

LED 0.5s On, 0.5s Off (En-

ter auto inclusion)

Reset

1. Pressing Include button three times Use this procedure only in

within 2 seconds will enter inclusion the event that the primary

mode.

controller is lost or

2. Within 1 second, press Include

otherwise inoperable.

button again for 5 seconds.

3. IDs are excluded.

LED 0.5s On, 0.5s Off (En-

ter auto inclusion)
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node ID

allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave

Controller.

LED Indication
There is a LED for identify function in the front case. PAN34 support the indicator ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05. To distinguish what mode the PAN34 is in, view from the LED for identification.

State Type Motor

LED Indication No matter up or down, close or open, Led will flash every second

4

activate No node ID Learning Overload

while Motor activate. When S1 or S2 close to L, the LED will flash even when the motor stop by itself, this is to let user know the S1 or S2 still close and not been release yet. Under normal operation, when the PAN34 has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or Include button, it will stop flashing temporarily. When PAN34 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals. When overload state occurs, the PAN34 is disabled and LED flashes on and off alternately at 0.2 second intervals. PAN34 will send alarm type=8 alarm Level=0xFF to Group1, Overload state can be cleared by disconnect and reconnect the PAN34 to the main power

Moving Range Calibration
1. It is important to carry out a shutter calibration process before you control the shutter to move. Press inclusion button over 3 seconds and release before the 6th second, the roller shutter controller will start the shutter calibration process. The process is composed of three continue stages. The shutter move to the TOP in first stage, and move to the BOTTOM in second stage, and move to the TOP again in third stage. Then PAN34 will know the total range from the BOTTOM to the TOP.
2. During the shutter calibration process, any emergencies happen you can press

and release the include button to stop the process.
3. If user found the direction is reverse, this may cause by the wrong connection of NC and NO to the motor, please exchange NC and NO connection and execute calibration process again.
4. For safe issue, please select the motor which can stop by itself when go to bottom end or top end.
Programming
1. Basic Command Class The PAN34 will respond to BASIC and BINARY commands that are part of the Z-Wave system.
1.1 BASIC_GET When PAN34 receive Basic Get Command, it will send Basic Report Command to report the position of the shutter. When the report value is 0x00, that mean the shutter is at the Bottom, if the report value is 0x63 that mean the shutter is at the Top, any other value between 0x01~0x62 imply Shutter at the position between top and bottom.
Basic Get Command: [Command Class Basic, Basic Get] Basic Report Command [Command Class Basic, Basic Report, Value = 0x00 (BOTTOM)] [Command Class Basic, Basic Report, Value = 0x01~0x62 (Between BOT-

5

TOM and TOP)] [Command Class Basic, Basic Report, Value = 0x63 (TOP)]

[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x63] control the shutter to the top (0x63)

1-2 BASIC_SET PAN34 can accept Basic Set Command which value is either (0x00) Bottom or Top (0x63) or (0x01-0x62) the position between TOP and Bottom. Other value (0x64-0xFE) is not acceptable.
[Command Class Basic, Basic Set, Value = 0x63] control the shutter to the top (0x63) [Command Class Basic, Basic Set, Value = 0x00(0)] control the shutter to the bottom(0x00) [Command Class Basic, Basic Set, Value = 0xFF] control the shutter to the most recent (non-zero) level. [Command Class Basic, Basic Set, Value = 0x01-0x62] control the shutter to the position between bottom and top
2. Multilevel Switch Command Class (Version 3)

[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x00(0)] control the shutter to the bottom(0x00)
[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0xFF(255)] control the shutter to the the most recent (non-zero) level.
[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x010x62] control the shutter to the position between Bottom and Top.
2-2 MULTILEVEL SWITCH GET:
When PAN34 receive Multilevel Switch Get Command, it will send Multilevel Switch Report Command to report the position of the shutter. When the report value is 0x00, that mean the shutter is at the Bottom, if the report value is 0x63 that mean the shutter is at the top, any other value between 0x01~0x62 imply shutter at the position between top and bottom.
Switch Multilevel Get Command [Command Class Multilevel Switch, Multilevel Switch Get]

2-1 MULTILEVEL SWITCH SET:
PAN34 can accept Multilevel Switch Set Command which value is either (0x00) Bottom or Top (0x63) or (0x01-0x62) the position between TOP and Bottom. Other value (0x64-0xFE) is not acceptable.

Multilevel Switch Report Command [Command Class Multilevel Switch, Multilevel Switch Report, Value = 0x00(BOTTOM)] [Command Class Multilevel Switch, Multilevel Switch Report,

Value = 0x01~0x62(Between BOTTOM and TOP)] 6

[Command Class Multilevel Switch, Multilevel Switch Report, Value = 0x63 (TOP)]
2-3 MULTILEVEL SWITCH START LEVEL CHANGE: This is the command which user can move the shutter up to the top or down to the bottom.
[Command Class Multilevel Switch, Multilevel Switch Start Level Change, Up/Down Value]

3. It may have some distance error caused by motor start up time. 4. If user found the error become significant, you may using S1 or S2 move
shutter to the end or remote move shutter to 0% and 100%, and that will automatically calibrate this error.
2-3.4 MULTILEVEL SWITCH STOP LEVEL CHANGE: When receive Multilevel Switch Stop Level change Command PAN34 will stop the motor.

2-3.1 Up/Down Bit: If Up/Down Bit=0x00 Shutter move up If Up/Down Bit=0x01 Shutter move down If Up/Down Bit=0x03 no move
[Command Class Multilevel Switch, Multilevel Switch Start Level Change, Up/Down=0x00] control the shutter to the top (0x63)
[Command Class Multilevel Switch, Multilevel Switch Start Level Change, Up/Down=0x01] control the shutter to the bottom (0x00)
[Command Class Multilevel Switch, Multilevel Switch Start Level Change, Up/Down=0x03] Don't move the shutter or stop the moving shutter
ATT. 1. Ignore Start LevelStart LevelDimming DurationInc/DecStep size can not be used.
2. PAN34 can not control the speed of motor.

Z-Wave's Groups introduction (Maximum 5 nodes) There is only one group called Lifelinethere is only 5 nodes for Group1 which support MULTILEVEL_SWITCH_REPORTMETER_REPORT_COMMAND_V3 NOTIFICATION_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION. 3-1 Device reset locally notification : When PAN34 is reset manually, it will send a DEVICE_RESET_LOCALLY_ NOTIFICATION to the nodes of group 1. 3-2 Report the shutter position  Every time when user press S1 or S2 and let shutter to move, PAN34 will report the position status to controller, and at the moving process when change over 10% PAN34 will send Multilevel Switch Report to Group 1 as well.
Multilevel Switch Report Ex. Report position at 30% [Command Class Multilevel Switch Multilevel Switch ReportValue = 30(%)] 3-3 Meter Command Class

7

The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I ) (5) load power factor (PF) to Z-Wave Controller after receive the Meter Get Command from Z-Wave Controller. When the power consumption of load vary over 5%, it will send Meter report to the nodes of Group as well
3-3.1 Instant Power Consumption (Watt) of Switch When receiving Meter Get Command, it will report Meter Report Command to the node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command: [Command Class MeterMeter ReportRate Type = 0x01Meter Type = 0x01Precision = 1Scale = 0x02Size = 4Meter Value(W) ]

the node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 (KW/h)] Meter Report Command: [Command Class MeterMeter ReportRate Type = 0x01 Meter Type =0x01 Precision = 2Scale = 0x00Size = 4Meter Value (KWh)]
Example: Scale = 0x00 (KWh) Precision = 2 Size = 4 Bytes (KW/h) Meter Value 1 = 0x00(KWh) Meter Value 2 = 0x01(KWh) Meter Value 3 = 0x38(KWh) Meter Value 4 = 0xA3(KWh)

Example: Meter Value 1 = 0x00 (W) Meter Value 2 = 0x00 (W) Meter Value 3 = 0x03 (W) Meter Value 4 = 0xEA (W) Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W

Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value 3*256) + (Meter Value 4) = 800.35 (KW/h)
3-3.3 AC load Voltage (V) When receiving Meter Get Command, it will report Meter Report Command to the node asked.

3-3.2 Accumulated Power Consumption (KW/h) When receiving Meter Get Command, it will report Meter Report Command to

Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]

8

Meter Report Command: [Command Class MeterMeter ReportRate Type = 0x01Meter Type = 0x01Precision = 1Scale = 0x04Size = 2 Meter Value(V)]

Size = 2 (2 Bytes of I) Meter Value 1 = 0x01(I) Meter Value 2 = 0x21(I) AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)

Example: Scale = 0x04 (V) Precision = 1 Size = 2 (2 Bytes of V) Meter Value 1 = 0x09(V) Meter Value 2 = 0x01(V) AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
3-3.4 AC load current ( I ) When receiving Meter Get Command, it will report Meter Report Command to the node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)] Meter Report Command: [Command Class MeterMeter ReportRate Type = 0x01Meter Type = 0x01Precision = 2Scale = 0x05Size = 2Meter Value(I)]
Example: Scale = 0x05 (I) Precision = 2

3-3.5 load power factor (PF) When receiving Meter Get Command, it will report Meter Report Command to the node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)] Meter Report Command: [Command Class MeterMeter ReportRate Type = 0x01Meter Type = 0x01 Precision = 2Scale = 0x06Size = 1 BytesMeter Value(PF)]
Example: Scale = 0x06 (PF) Precision = 2 Size = 1 (1 Byte of PF) Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)
3-3.6 Reset Accumulated Power Consumption (KWh) Whenever re-start counting the accumulated power consumption is needed, you can use Meter Reset Command to clear it.
Meter Reset Command[Command Class Meter, Meter Reset]

9

4. Notification Report Command

When PAN34 detect Overload, it will send Notification Report to Group1, Notification

_Type = 0x08, Notification State=0x08. When it receive Notification Get command

with Notification Type = 0x08 and the PAN34 not in overload status, it will send Notifi-

4

cation Report, Alarm Type = 0x08, Notification State=0x00. 5
When PAN34 detect an overload power, it will send Notification Report to Group1.

[Command Class Notification, Notification Report, Notification Type = 0x08,

Notification State = 0x08 (Overload)]

[Command Class Notification, Notification Report, Notification Type = 0x08,

6

Notification State = 0x00 (Normal)]

When in Two Push Button switch type, S1 or S2 are closed and not released to open, and PAN34 receive any control moving command from Z-Wave RF.

moving

time of

curtain

Watt

1

threshold

Watt

1

differential

Timer

2

offset for

motor

start

running

1-5

Watt 1

0-1

1

0-255

0.01 50
second

1~6000: 0.1s~600s
The threshold is a judgment for motor running or not
0: It will not report Watt when change over 5%
1: It will report watt value when the differential is over 5%
0-255: 0s ~ 2.55s
50 = 0.5s

5. Z-Wave's Configuration

5-1 Watt Meter Report Period:

Configuration Parameter
1
2
3

Function
Watt Meter Report Period External switch mode Total

Size (Byte) 2
1
2

Value 0 0x7FFF
1-2
0-6000

Unit 5s
0.1
Second

Default Description

720

0:Disable auto Report

1~0x7FFF: 5s ~45

hour

2

1: One Push button

2:Two Push button

0

0: The time depends on Moving Range

Calibration

If the setting is configured for 1hour (set value =720), the PAN34 will report its instant power consumption every 1 hour to the node of Group 1. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Default value is 1 hour. If the setting value is 0, the auto report function of meter Watt will be disabled.
5-2 External switch mode
5-2-1 One Push Button
When the configuration setting is One Push Button, only S1 input will be valid. The control moving commands can be accepted in this switch mode while the shutter is moving. In this switch mode, the inclusion/exclusion/reset function can also be fulfilled by pressing S1 just like the operation of include button. 10

When S1 is short pressed, the shutter will move up toward TOP(0x63). While in this moving S1 is short pressed again, the shutter will stop moving. A third short pressing of S1 will move the shutter down toward BOTTOM(0x00). While in this moving S1 is short pressed again, the shutter will stop moving. And so on... Inverting direction and stopping.
5-2-2 Two Push Button (The default setting is Two Push Button (2))
If this setting is configured as Two Push Button, S1 and S2 input will be valid, but will not accept pressing S1and S2 at the same time. In this switch mode, the inclusion/exclusion/reset function can also be fulfilled by pressing S1 or S2 just like the operation of include button.
When S1 is pressed and hold more than 1.5 seconds, the shutter will move up toward TOP(0x63), and the shutter will stop moving when S1 is released. When S2 is pressed and hold more than 1.5 seconds, the shutter will move down toward BOTTOM(0x00), and the shutter will stop moving when S2 is released.
When S1 is short pressed, the shutter will move up toward TOP(0x63). While in this moving short pressed S1 again, the shutter just keep moving up toward
TOP(0x63). The easy way to stop this moving is short pressing S2. When S2 is short pressed, the shutter will move down toward BOTTOM(0x00). While in this moving short pressed S2 again, the shutter just keeps moving down toward BOTTOM(0x00). The easy way to stop this moving is short pressing S1.
When in Two Push Button switch mode, S1 or S2 are pressed and not released, and PAN34 receive any control moving command from Z-Wave RF (Ex. BASIC_SET BINARY_SWITCH_SETMULTILEVEL_SWITCH_SETMULTILE VEL_SWITCH_START_LEVEL_CHANGE or

MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE), PAN34 won't do any change in position. ATT. : For avoid misunderstanding that RF command dose not work, it is
recommended to check the status of S1 and S2.

5-3 Total moving time of curtain This a way for setting the total moving time of curtain manually. You can count the time when shutter move from BOTTOM to TOP by long pressing S1 or S2. But if the time is set as 0, the total moving time of shutter will be the value set by Moving Range Calibration which is describing in Page 3. The default value is 0.
5-4 Watt threshold The threshold is for PAN34 judging if the motor is running or not. The default value is 1 watt.
5-5 Watt differential Whenever the watt value varies over 5%, PAN34 will send the meter report to group 1 nodes. The default value is 1 (5%).
5-6 Timer offset for motor start running This parameter is an offset to count for starting time of the motor. It will improve the inaccurate when moving to the middle position. The default value is 50.

6.Command Classes The Switch supports Command Classes including...

Command Class

Version

Required Security Class

11

Z-Wave Plus Info

2

Security 0

1

Security 2

1

Supervision

1

Transport Service

2

Association

2

Association Group Information

3

Basic

2

Configuration

4

Device Reset Locally

1

Firmware Update Meta Data

5

Manufacturer Specific

2

Window Covering

1

Power level

1

Multilevel Switch

4

Meter

3

Notification

8

Indicator

3

Multi Channel Association

3

Version

3

None None None None None Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class

Disposal
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Philio Technology Corporation 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C) www.philio-tech.com
FCC Interference Statement This equipment has been tested and found to comply with the limit's fora Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
12

· Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
:
     
13

