Wissenergy P60 Portable Charger Instruction Manual
1. Appearance Details of the Charger
The charger consists of the following components:
- 1 - Cable
- 2 - Charging Connector
- 3 - In-Cable Box
- 4 - Power Plug
- 5 - LED Light
Diagram showing the charger components with labels 1 through 5.
2. Charging State Indicator
The LED indicator on the in-cable box shows the charging status:
Charging State | Indicator Light |
---|---|
Disconnected | Upper green light |
Connected Mode | All green lights on |
Charging Mode | Rolling green light |
Finish Mode | All green lights on |
Fault Mode | Flashing red light on |
Diagram illustrating the LED indicator states for different charging conditions.
3. Quick Operation Guide
- Insert the power plug into the power socket. The green light (Disconnected) will illuminate, indicating the start-up is complete.
- Plug in the charging connector. The green indicator light (Connected) will illuminate.
- Charging will begin automatically, and the green indicator light (Charging) will start rolling.
- To stop charging, simply pull out the charging connector.
Note: The socket wire harness must have a cross-section greater than 2.5 mm².
Diagram showing the connection process of the electric vehicle and the charger.
4. Technical Parameters
- Product Name: P60 CE Standard Electric Vehicle Charger
- Certificate: CE/ROHS
- External Dimensions: 261*107*65 mm
- Input Voltage: 400V AC Three-Phase
- Input Current: 16 A
- Maximum Power: 11 kW
- Standard: EN62752
- IP Class: IP66
QR code linking to detailed instructions.
5. Precautions For Use
- Failure to follow the instructions may result in danger.
- Please use the charging station only if it is in a technologically normal and safe condition.
- Prevent children from accessing the charging station.
- Install the charging station away from pyrotechnics, dust, and corrosive substances.
- The output of the charging station is high voltage; exercise caution for your safety during use.
- In case of a fault, electric shock or even death may occur. In emergency situations, disconnect the power supply.
- Do not disassemble the charging station during charging.
6. Safety Warning
- Failure to follow the instructions may result in danger!
- Regularly check the charging station for visible damage. Using a damaged charging station may cause electric shock.
- Ensure that all safety devices are always available and test them regularly to ensure proper operation.
- In case of a ground fault, it should be assumed that the base cable is live. After confirming that there is no high voltage in the system, check the charging station.
- Installers and users must observe principles and regulations to ensure their safety and the safety of the equipment.
- Before powering up the equipment, ensure it is properly grounded to avoid unnecessary accidents.
- All tools that do not require exposed metal parts should be insulated to prevent exposed metal parts from touching the metal frame and causing a short circuit.
- Do not modify, reconstruct, or change any part under any circumstances.
- Before powering up the equipment, ensure that the input voltage, frequency, circuit breakers, and other conditions meet the specifications.
- This product must be installed by authorized personnel.
- Before using the product, check if it meets local regulatory requirements.
- The recommended height for hanging the connector is 0.4-1.5 m above ground level.