Technical Parameters for Solid Fuel Local Space Heaters
EU 2015/1186 of 24 April 2015
Model Information
Model identifier(s): Jøtul F 405
Indirect heating functionality: no
Direct heat output (kW): 7,0
Indirect heat output (kW): N.A.
Fuel Specifications
Fuel | Preferred fuel (only one): | Other suitable fuel(s): | Emissions from space heating at nom | |||
---|---|---|---|---|---|---|
PM | OGC | CO | NOx | |||
Wood logs with moisture content ≤ 25% | Yes | No | 6 | 52 | 749 | 79 |
Compressed wood with moisture content < 12% | No | No | ||||
Other woody biomass | No | No | ||||
Non-woody biomass | No | No | ||||
Anthracite and dry steam coal | No | No | ||||
Hard coke | No | No | ||||
Low temperature coke | No | No | ||||
Bituminous coal | No | No | ||||
Lignite briquettes | No | No | ||||
Peat briquettes | No | No | ||||
Blended fossil fuel briquettes | No | No | ||||
Other fossil fuel | No | No | ||||
Blended biomass and fossil fuel briquettes | No | No | ||||
Other blend of biomass and solid fuel | No | No |
Emissions values in mg/Nm³ (13% O2)
Characteristics when operating with the preferred fuel
Seasonal space heating energy efficiency ηs [%]: 73
Energy Efficiency Index (EEI): 110,4
Heat Output
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Nominal heat output | Pnom | 7,0 | kW | Useful efficiency at nominal heat output | ηth, nom | 83 | % |
Minimum heat output (indicative) | Pmin | N.A. | kW | Useful efficiency at minimum heat output (indicative) | ηth, min | N.A. | % |
Auxiliary electricity consumption
Item | Symbol | Value | Unit |
---|---|---|---|
At nominal heat output | Pelmax | x,xxx | kW |
At minimum heat output | Pelmin | x,xxx | kW |
In standby mode | PelSB | x,xxx | kW |
Type of heat output/room temperature control
Single stage heat output, no room temperature control | [yes/no] | Yes |
Two or more manual stages, no room temperature control | [yes/no] | No |
With mechanic thermostat room temperature control | [yes/no] | No |
With electronic room temperature control | [yes/no] | No |
With electronic room temperature control plus day timer | [yes/no] | No |
With electronic room temperature control plus week timer | [yes/no] | No |
Other control options (multiple selections possible)
Room temperature control, with presence detection | [yes/no] | No |
Room temperature control, with open window detection | [yes/no] | No |
With distance control option | [yes/no] | No |
Permanent pilot flame power requirement
Item | Symbol | Value | Unit |
---|---|---|---|
Pilot flame power requirement (if applicable) | Ppilot | N.A. | kW |
Supplier Information
Sign: Espen Auensen, R&D manager
Contact details: Name and address of the supplier: Jøtul AS, P.O. box 1411, 1602 Fredrikstad, Norway