Air-Cooled Chillers Deliver Rapid Restart™ Capability
When the power goes out, Trane keeps it cool.
For many mission-critical applications, bringing a chiller back online rapidly after a power loss is crucial. When every second counts, having this rapid restart capability proven on the test stand demonstrates the chiller's ability to adapt to power-loss situations.
Trane systems deliver Rapid Restart capabilities, offering industry-leading start-up times in the event of a power outage. Once power is restored, your Trane system is fully back in operation in two minutes or less. Competitive rooftop equipment can take up to 15 minutes, long enough for servers to overheat and shut down. With Trane Rapid Restart, the mechanical cooling starts up before the servers heat up.
Image shows two Trane air-cooled chiller units: the Ascend™ Air-Cooled Chiller Model ACR and the Air-Cooled Magnetic Bearing Chiller Model TCA.
Trane understands that every second counts.
Trane equipment, controls, and control sequences are designed to get your system back online and properly functioning should your facility experience a power cycle event.
- Trane HVAC system design is optimized for fast restart, providing mechanical cooling in 120 seconds or less.
- RTU controls and equipment provide an integrated, pre-engineered solution for fast restart.
- Proven operational procedures maximize uptime during critical outages and get the system up and running as quickly as possible.
- Rapid Restart can be programmed at the chiller control panel to occur anytime unit high voltage power is lost and restored.
- All compressors are started at once.
- No external signal is required to initiate Rapid Restart; programming is done at the unit level.
- Ramp up time to 80% load is about 3 minutes.
Chiller Rapid Restart Sequence of Events
Time | Event |
-10 seconds | Chiller running at "X" TonR and power is turned off |
0 seconds | Main power is re-established on the unit |
64 seconds | Compressors get the start command and they all ramp up together |
135 seconds | Compressor status become operational and keep loading with PID loop |
160 seconds | Chiller is producing more than 80% "X" capacity |
~250 seconds | At 100% load |
Note: Without Rapid Restart, the time increased to 15 minutes until the chiller gets to its 80% "X" capacity.
Smaller Tanks, Bigger Savings with Trane Rapid Restart™
Reduce thermal storage cost.
Trane's industry-leading Rapid Restart capability means your chiller can be back online and restoring comfort in 120 seconds or less after a power outage. With such high-speed recovery, your building's chilled water system doesn't need large storage tanks to bridge the gap during power interruptions.
Why does restart speed matter?
When a chiller can return to operation quickly, it reduces the reliance on large, expensive thermal storage tanks. This translates to:
- Lower capital investment: You don't need to oversize your chilled water tank to compensate for long downtime.
- Smaller footprint: Less space required for tanks means more usable space in your facility.
- Reduced operational cost: Minimizing tank size also reduces maintenance and operating expenses.
Graph titled 'Tonnage% vs time (min)' showing a curve that rises steeply from 0% tonnage at 0 minutes to approximately 80% tonnage by 3 minutes, then levels off towards 100% tonnage around 7 minutes.
Design with confidence.
Trane's Rapid Restart technology allows you to optimize your system design for speed and efficiency. In applications where thermal storage is required, rapid restart lets you specify smaller tanks and invest in what matters most to your facility. Stay cool, spend less, and trust Trane to recover quickly—so your mission-critical operations keep running smoothly.
The complete package.
Trane not only provides customers with data center solutions but also ensures individual needs are met, installation is done properly, usage is understood, and service is ongoing. Trane sets customers up for success through:
- Pre-sale support: Trane experts make the most thorough recommendations possible.
- Best-in-class service: Throughout the installment process, Trane is with customers every step of the way. Trane experts go through comprehensive training processes to provide customers with the counsel needed for effective equipment use. Trane also offers technical training at its facilities across the United States.
- Post-sale support: Trane Intelligent Services enable real-time monitoring of your chiller operation 24/7/365, leading to improved energy efficiency, higher productivity, and reduced costs.
With industry-leading expertise and a wide array of solutions and services, Trane—a holistic provider—can help customers ensure data center facilities are highly reliable, efficient, and sustainable. Trane's application engineering expertise and systems approach allows for efficient, flexible, and scalable integrated designs, meeting specific customer needs that ensure uptime and performance is at the forefront of any data center implementation project.
[Mission Critical logo/description]
Trane experts and its broad solutions portfolio can help transform data centers with experience, innovation, and passion for making buildings better—all while helping reduce energy intensity and ensure uptime.
Contact your Trane Account Manager to get started today!
Related Documents
![]() |
Trane Air-Cooled Chillers: Sustainability, Efficiency, and Performance Explore Trane's comprehensive range of air-cooled chillers and heat pumps, including models like CGAM, RTAF, ACS, ACR, ACX, and TCA. Discover advanced features for sustainability, energy efficiency, quiet operation, and reliable performance in commercial HVAC applications. |
![]() |
Trane Data Center Cooling Solutions: Line Card Comprehensive overview of Trane's thermal management solutions for data centers, including chillers, air handlers, and liquid cooling systems, focusing on efficiency, reliability, and advanced technology. |
![]() |
Trane Sustainable Cooling Innovations for Bangkok Skyscraper - Green Mark Platinum Success Case study detailing Trane's sustainable cooling innovations for a Bangkok skyscraper, achieving Green Mark Platinum certification with advanced chiller plant management systems and energy efficiency. |
![]() |
Trane TCAA Packaged Air-Cooled Magnetic Bearing Chiller: Installation, Operation, and Maintenance Manual This February 2024 manual from Trane Technologies provides comprehensive guidance for the installation, operation, and maintenance of the TCAA series Packaged Air-Cooled Magnetic Bearing Chillers. It covers safety, system details, operational procedures, and maintenance requirements for optimal performance. |
![]() |
Trane Sintesis Advantage CGAF Air-Cooled Chiller: Features, Specifications, and Data Explore the Trane Sintesis Advantage CGAF Air-Cooled Chiller, a versatile and efficient HVAC solution. This document details its key features, technical specifications, and comprehensive product data for various models, highlighting energy savings and reliability. |
![]() |
Trane RAUJ Split System Cooling Condensers and Remote Chillers Product Catalog Explore the Trane RAUJ series of Split System Cooling Condensers and Remote Chillers, available from 20 to 120 tons. This comprehensive product catalog details advanced features, technical specifications, performance data, and essential application considerations for efficient and reliable HVAC solutions. |
![]() |
Trane CGAM Air-Cooled Scroll Chillers: Installation, Operation, and Maintenance Manual Comprehensive guide for the installation, operation, and maintenance of Trane CGAM Air-Cooled Scroll Chillers. Covers safety warnings, environmental concerns, model number descriptions, and detailed operational procedures. |
![]() |
Trane RTAC Rotary Chiller Tracer AdaptiView Display Upgrade Kit Installation Instructions This document provides detailed installation instructions for the Trane Tracer AdaptiView Display Upgrade Kit for RTAC Rotary Chillers, replacing older DynaView systems. It covers safety, required tools, step-by-step procedures, and integration options. |