TDR83 WIFI THERMOSTAT USER GUIDE

technicians. 3.After installation, please read this manual carefully and operate the product according to the instructions. Caution: Risk of electric shock or equipment damage.
Wiring Diagram

Note: WP for water heating; EP for electric heating; WPB for gas boiler

THIS THERMOSTAT IS SUITABLE FOR WATER HEATING, ELECTRIC HEATING AND GAS BOILER
Welcome
Thank you for your trust and support. By adopting higher-end technology and more perfect technology, your new thermostat will provide you with the right temperature environment every day in the future, making your life more comfortable and your living environment more stylish and beautiful. For detailed instructions on the installation and use of this thermostat, please read this manual carefully. Please contact a professional to install the thermostat for you and install and use the product to the extent permitted by law.
Application
Intelligent digital temperature controller is a floor heating system suitable for room temperature control and household temperature control. It controls the operating state of the floor heating equipment by comparing the ambient temperature with the set temperature, which improves comfort and achieves energy saving. This digital temperature controller adopts microcomputer control technology and is equipped with full-screen display touch buttons, which is elegant in design and easy to use. The thermostat has manual automatic, programmable and state memory functions.

Installation procedure
This product is installed with a standard 86 control switch (in compliance with European regulations).

1.

2.

3.

4.

1. Slide the mounting plate upward in this direction. 2. Remove the mounting plate in this direction. 3. Fix mounting plate to cassette with screw. 4. After installation, buckle the product in this direction.

Description of display & Icon

Product packaging
Thermostat host 1 PC Sensing line (optional) 1 PC Screw 2 PCS

Qualification certificate Manual 1 PC

1 PC

Product Model
WP Plumbing 3A EP Electric Heating 16A WPB linkage, gas boiler 3A

User Notes
1.Please read this manual carefully. Improper operation may damage the product or cause dangerous conditions. 2.The installation personnel must be well-trained and experienced service

Operating Instruction

1. Power on/off: press to turn on/off the thermostat.

2. Press the

key to switch between manual and automatic modes.

3. In the automatic mode, press or to adjust the temperature to enter the automatic temporary mode. This mode runs for only one session.

4. Long press

key and

key to enter the clock setting, press key to

switch Settings Item, press

and

keys to adjust the value of each

parameter. Note: the time of WIFI model will be Automatically gets Internet time

5. Press and for 5 seconds to add or cancel the child lock. 6. WIFI link: When the thermostat is on, long press button for 5 seconds and the thermostat display will come out Now the WIFI icon flashes, at this time the thermostat into the state of code.

Time programming instructions
Press and hold the key to enter the programming setting, short press the key to switch the option, press the key or key to adjust each option parameter, and press the key to exit and save.

KEY

OPTION ICON

TIME ADJUST DEFAULT ADJUST

1 2 workday 3 4 5 6
Holiday 1 2

06:00 08:00 11:30 12:30 17:00 22:00 08:00 23:00

20 15 15 15 22 15 22 15

Advanced options

When POWER OFF, press the the advanced option setting.

key and the

key for 5 seconds to enter

Press to enter the next option, press to exit the height Level option.

and to adjust, and press

Temperature 1
compensation

The default value of the calibration room temperature is -2 . Press the up and down keys to adjust. The adjustable range is 9.9 °C to -9.9 .

The temperature sensor is selected as IN by default.

2 Sensor selection Press the up and down keys to adjust as IN respectively,

indicating that the internal.

Modify the

The default temperature limit value is 35 . Press the up

3

temperature limit and down keys to adjust the range from 5  to 60 .

Temperature 4
difference start

The default temperature difference is set to 1 . Press the up and down keys to adjust the range to 1-10 degrees.

Set the default anti-freeze function to OFF, display OFF, 5 Antifreeze function
press the up key to tum on anti-freeze and display ON.

Set the default rest day as double OFF. Press the up and Holiday option and

down keys to adjust It to double OFF (1-5), single OFF 6 turn off weekly

programming

(1-6), no OFF (1 -7) and tum off week programming

(OFF).

About WIFI connection
Before using the WIFI thermostat for the first time, you should set the WIFI signal and configuration through your smart phone or tablet to allow communication between your connected devices. 1. Download the APP Search for "Tuya" in App market or scan below QR Code to download
2. Register Account If you don't have an APP account yet, you can choose to register or log in via SMS verification code. Click "Create a new account", you will enter the Tuya Smart Platform Privacy Policy page. After you click Agree, you will officially enter the mobile phone registration page.
The system automatically determines the current country/region. You can also select the country/region manually. After entering your mobile phone number or email address, click "get verification code" . Enter the received verification code, then enter the password, and click "finish" to register successfully.

Primary

and Set the default main and auxiliary reversal to 0. Press the

7 secondary reverse up and down keys to adjust 0 to tum off the main and

selection

auxiliary reversal. 02 means auxiliary reverse.

Passive linkage Set the default passive linkage delay time to 0. Press the 8
output delay time up and down keys to adjust the range of 0-5 minutes.

Set upper

The default value of the set temperature upper limit is

9 temperature limit 60, and the adjustment range Is 35-95  by pressing

Restore Factory 10
Defaults

the up and down keys. Set to restore the factory default setting to display "-", Press the up button to adjust the display "---", press the enter button to restore the factory settings

3. Add device Click "add device" or"+" on the top right of the APP homepage to enter the "add device" page. Currently, there are two ways to manually add device and search device.

Find the thermostat product (WIFI model) in the device list. In the specified network mode, the indicator flashes (slowly flashes) and then click the confirm button on the page. Select the device's work area to connect to the WIFI of the Internet and enter the WIFI password. Click "ok" to enter the matching network process.

4. Display of temperature controller APP interface

If the default mode distribution network is selected, the distribution process APP is shown in figure 1 below, and the distribution network successfully displays the interface shown in figure 2. The name of the device can be changed or the location of the room can be selected.

If the distribution network fails, the APP will display the page shown in the figure below. You can choose to add or view the help again. Note: if the connection fails, please confirm whether the temperature control device has entered the code matching state, refer to item 6 of the operation manual.


WPS 文字