Instruction Manual for ActronAir models including: REPE-01, REPE-01 Mini VRF Controllers, REPE-01, Mini VRF Controllers, VRF Controllers, Controllers
ActronAir Digital
Manuals - ActronAir
File Info : application/pdf, 20 Pages, 1.82MB
DocumentDocumentREP EA TER Operation Manual Model Number REPE-01 3&1& 3FQFBUFS IMPORTANT NOTE: Please read this manual carefully before installing or operating your air conditioning unit. Contents Operating Precautions 01 Instructions Main Parameters 01 Product Overview 02 Descriptions on Indicators 03 Installation Precautions 04 Instructions Package Contents 05 Repeater Installation 06 Power Cable Connection 08 Communication Wire Connection 10 Operating Instructions Precautions Entrust a qualified local technician to perform installation. Do not try to install the unit by yourself. Before cleaning or maintenance, ensure the power supply is cut off. Do not use water for washing to prevent electric shocks. Do not operate with wet hands to avoid electric shocks. Do not use pesticides, disinfectants, or flammable directly on the controller as they may damage the device or cause fires. When the IDUs are powered separately and the number of IDUs to be connected is more than 10 or the communication distance is larger than 200, repeaters are required. Main Parameters Name Rated Voltage Operating environment temperature Operating environment humidity REPE-01 216-253V 50HZ -543 RH90 01 Product Overview 3&1& 3FQFBUFS A repeater is a connector working on the physical layer, with the following features: Signal repeater: re-transmits or forwards data signals to extend the network transmission distance. Power supply repeater: compensates the voltage drop caused by communication wire resistance to increase the bus voltage. 02 Descriptions on Indicators 3&1& 3FQFBUFS Communication indicator (yellow) Communication indicator (blue) Short circuit indicator (red) Power indicator (green) Indicator Communication indicator Communication indicator Short circuit indicator Power indicator Normal Blinking Blinking Off On Abnormal On/off Remarks Abnormal communication On/off On Off Abnormal communication Short circuit of communication bus downstream the repeater Abnormal power supply for the main board 03 Installation Instructions Precautions To ensure correct installation, read the "Installation Instructions" section of this manual. All the warnings provided here are important for safety and must be followed. Warning Entrust the local distributor or local service agent to appoint a qualified technician to perform the installation. Do not try to install the unit by yourself. Do not connect the communication wire when the power is on. Otherwise, the circuit board will be damaged. Do not connect the power cable (high voltage) to the communication (low voltage) terminal. Otherwise, the circuit board will be damaged. Do not connect M1M2 with the PQ of IDU. Otherwise, the circuit board will be damaged. Note the distinction between the communication port of the upstream IDU and that of the downstream IDU. Be careful not to make them confused. Otherwise, communication failure will occur. Use the specified cables as the communication wiresThe wires should be fixed with clamps to avoid stress on the terminal block. Do not install the repeater in any corrosive, flammable or explosive environment or place with oil mist (such as a kitchen). Do not install the repeater outdoor or in a wet place and avoid direct sunlight. Do not knock, throw, or disassemble the wired controller. Please install the repeater after painting the wall to prevent water, lime and sand from entering the repeater. When installing the equipment, all requirements of the mentioned standard must be fulfilled. And when necessary, suitable enclosure and type of supply connection should be provided by end system 04 Product List The below items are included when ordering the repeater: No. Description 1 REPE-01 repeater 2 Installation and Operation Manual 3 Philips head screw 4 White plastic expansion pipe 5 Crimp clamp Cross recessed pan head 6 tapping screw (3.9x10) 7 Cross recessed pan head tapping screw (2.9x8) Quantity Remarks 1 Used to increase bus voltage 1 Providing instructions on repeater installation 4 Used to fix the pedestal 4 Used to fix the pedestal 4 Used to fix the wire 8 Used to fix the crimp clamp 2 Used to fix the box cover and pedestal after installing 05 Repeater Installation . Push the cover hard on the screwdriver icon till snap fasteners of the cover seperate from the base, then open the cover. Install the power cables and communications wires properly according to the wiring diagram. Snap fastener Warning Make sure the power is off when operating. Do not raise the upper cover with excessive force to avoid damage to the cover or the circuit board. 06 . Fix the repeater base on the wall or a proper location with a screwdriver. Four positions need to be fixed with screws. Location to accept a screw . Finally, close the upper cover and the bottom cap of the repeater and tighten them with two fixing screws. Fixing screw Warning Make sure that no cables are clamped when buckling the upper cover and bottom cap of the repeater. 07 Power Cable Connection Warning The power supply of the repeater cannot be cut off separately. It needs to be always powered on or switched on and off with the ODU power supply. Use round-type terminals with correct specifications to connect the power cable. The power cables must be a 2×1.0mm2 copper core cable. Connect the power cable with the terminals L and N. Connection of the power cable First wiring method: Let the power cable through the hole on the left side of the repeater to the CN1 power supply terminal (L N). Fix the wires with clamps to avoid stress on the terminal block. Wire clamp Hole to pass wire LN LN CN1 08 Connection of the power cables Second wiring method: Let the power cable through the hole on the bottom side of the repeater to the CN1 power supply terminal (L N). Fix the wires with tie to avoid stress on the terminal block. LN CN1 Hole to pass wire on the bottom LN Hole for tie on the bottom 09 Communication Wire Connection Warning Do not connect M1M2 with the IDU's PQ, D1D2 or X1X2 or any other different communication network. Otherwise, the circuit board will be damaged. If the total communication distance between IDU and ODU exceeds 200m or more than 10 IDUs are configured, use a repeater to increase the bus voltage. A maximum of 2 repeaters can be installed in the same refrigerant system. Use 2×1.5mm2 PVC sheathed flexible cords in compliance with AS NZS 3000 Electrical installations (known as the Australian New Zealand Wiring Rules) and AS NZS 3008 Electrical Installations (DC resistance 1.33/100m) as communication cables. Note the distinction between the communication port of the upstream IDU and that of the downstream IDU. Be careful not to make them confused. Otherwise, communication failure will occur. Connect the port of TO UP IDU with the upstream IDU. The upstream IDU is located in front of the repeater and near the ODU. Connect the port of TO DOWN IDU with the downstream IDU. The downstream IDU is located behind the repeater and away from the ODU. Master ODU IDU ··· Repeater IDU 3&1" 3FQFBUFS M1 M2 Upstream IDU 10 IDU IDU ··· Downstream IDU Connection of communication wires First wiring method: The communication wire should pass through the wire clamp on the right side of the repeater. The communication wire of the upstream IDU should be connected with CN3 (TO UP IDU) terminal block(M1 M2) while the communication wire of the downstream IDU connected with CN2 (TO DOWN IDU) terminal block(M1 M2). The wires should be fixed with clamps to avoid stress on the terminal block. Wire clamp CN2 CN3 CN2(M1 M2) TO DOWN IDU (connected with the downstream IDU) CN3(M1 M2) Hole to pass wire TO UP IDU (connected with the upstream IDU) Warning Do not connect the communication wire when the power is on, or the circuit board will be damaged. Note the distinction between the upstream IDU and the downstream IDU. Be careful not to make them confused. Otherwise, communication failure will occur. Please follow the path shown in the figure. The path cannot touch the components on the motherboard. 11 Connection of communication wires Second wiring method: The communication wire should pass through the wire clamp on the bottom side of the repeater. The communication wire of the upstream IDU should be connected with CN3 (TO UP IDU) terminal block(M1 M2) while the communication wire of the downstream IDU connected with CN2 (TO DOWN IDU) terminal block (M1 M2). The wires should be fixed with tie to avoid stress on the terminal block. CN2 CN3 Hole to pass wire on the bottom CN2(M1 M2) TO DOWN IDU (connected with the downstream IDU) CN3(M1 M2) Hole for tie on the bottom TO UP IDU (connected with the upstream IDU) 12 Connection mode Master ODU CN23 M1 M2 L1 M1 Circuit breaker M2 CN10 CN1 LN La Power supply for IDU ··· IDU 2-9# IDU 1# Ly TO DOWN IDU M1 M2 CN2 CN3 M1 M2 TO UP IDU repeater 2 L21 M1 M2 L N CN10 CN1 IDU 20# Lc Lx M1 M2 CN10 CN1 LN IDU 10# Lb ··· IDU 12-19# L30 Communication wire Power cable TO DOWN IDU M1 M2 CN2 CN3 M1 M2 TO UP IDU repeater 1 L11 M1 M2 CN10 CN1 LN IDU 11# M1 M2 L N CN10 CN1 ··· IDU 22-28# M1 M2 L N CN10 CN1 M1 M2 L N CN10 CN1 IDU 21# IDU 29# IDU 30# L1+La+Lx200m, L11+Lb+Ly200m, L21+Lc+L30200mm, communication wire: 2×1.5mm2. The above figure shows a connection in series. Please refer to the installation manual of the outdoor unit and the respective controller and or please contact ActronAir Technical support for assistance. 13 Warning If the total communication distance does not exceed 200m and no more than 10 IDUs are configured, the units are powered by the master ODU and no repeaters are required. If the total communication distance exceeds 200m or more than 10 IDUs are configured, repeaters are required. The repeaters shall have the same load capacity as the ODUs, connecting with up to 10 IDUs, with a communication distance of no greater than 200m. A maximum of two repeaters can be installed in the same refrigerant system. A maximum of 30 IDUs can be installed in the same refrigerant system by using repeaters. Communication and Power Supply Capacity of Equipment Equipment Wire diameter Distance Number of nodes Master ODU 1.5mm2 200m 10 Repeater 1.5mm2 200m 10 14 THIS PAGE WAS INTENTIONALLY LEFT BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ©Copyright 2023 Actron Engineering Pty Limited ABN 34 002767240. ®Registered Trade Marks of Actron Engineering Pty Limited. ActronAir is constantly seeking ways to improve the design of its products, therefore, specifications are subject to change without notice. Operation Manual - Mini VRF Controllers REPE-01 Document: 9590-3036-11 Ver. 1 230822Adobe PDF library 17.00 Adobe Illustrator 27.8 (Windows)