Planika Senso Fireplace
Installation Manual
Document Version: 01.03.2022
Document Number: I1499#00
Product Overview
This document provides installation instructions for the Planika Senso Fireplace. It covers general dimensions, specific installation types (Single Sided, Left/Right Corner, Three Sided), burner installation steps, cladding requirements, and safety considerations.
General Dimensions
Diagram Description: A 3D isometric view of the Planika Senso Fireplace unit is presented. Inset diagrams show main components. Overall dimensions are provided in millimeters: Width 749, Depth 703, Height 562, Height without top 451, Depth from front 85, Top thickness 40.
Installation Types and Dimensions
1. Single Sided Installation
Diagram Description: An isometric view illustrates the required wall cavity dimensions for a single-sided installation. Key dimensions are labeled W, W1, W2, D, D1, H, H1.
Type | W (mm) | W1 min (mm) | W2 max (mm) | D (mm) | D1 max (mm) | H (mm) | H1 min (mm) |
---|---|---|---|---|---|---|---|
Senso Fireplace Single Sided | 710 | 370 | 170 | 350 | 25 | 455 | 130 |
Electrical Connection Requirement: Minimum 3x1.5 mm² cable, 230 V, 50 Hz, with PE [protective earth] connection.
2. Left / Right Corner Installation
Diagram Description: An isometric view illustrates the required wall cavity dimensions for a left or right corner installation. Key dimensions are labeled W, W1, W2, D, D1, H, H1.
Type | W (mm) | W1 min (mm) | W2 max (mm) | D (mm) | D1 max (mm) | H (mm) | H1 min (mm) |
---|---|---|---|---|---|---|---|
Senso Fireplace Left/Right Corner | 706 | 370 | 170 | 350 | 25 | 455 | 130 |
Electrical Connection Requirement: Minimum 3x1.5 mm² cable, 230 V, 50 Hz, with PE [protective earth] connection.
3. Three Sided Installation
Diagram Description: An isometric view illustrates the required wall cavity dimensions for a three-sided installation. Key dimensions are labeled W, W1, W2, D, D1, H, H1.
Type | W (mm) | W1 min (mm) | W2 max (mm) | D (mm) | D1 max (mm) | H (mm) | H1 min (mm) |
---|---|---|---|---|---|---|---|
Senso Fireplace Three Sided | 701 | 370 | 166 | 350 | 25 | 455 | 130 |
Electrical Connection Requirement: Minimum 3x1.5 mm² cable, 230 V, 50 Hz, with PE [protective earth] connection.
Installation Procedure
Burner Installation Steps
Diagram Description: The installation process for the burner unit is shown in sequential steps. Step 1 involves connecting the power cable (labeled 1) to the unit. Step 2 shows attaching a mounting bracket (labeled 2) using screws; this hardware is noted as 'Not supplied'. Step 3 depicts inserting the burner unit (labeled 3) into the prepared fireplace housing. Step 4 indicates the direction of insertion with a curved arrow.
Note: This procedure is detailed in the 'Installation manual Senso Burner (I1495)'.
Finishing and Safety
Cladding Material Installation
Diagram Description: Illustrates the process of attaching cladding material around the fireplace opening. A positioning tolerance of +/- 2mm is indicated. It is crucial to ensure the 'Visible edge' of the cladding material is properly finished and covered.
Multilingual Instruction Summary: Ensure the visible edge of the cladding material is finished. (This instruction is provided in English, German, Spanish, French, Italian, Polish, and Russian).
Installation Options: Deflectors and Materials
Diagram Description: Shows different installation options. One diagram illustrates the placement of a deflector component (labeled B). Another diagram depicts a non-flammable material barrier, which requires a minimum distance of 1000 mm from the fireplace.
Options include installing a deflector (B). When using surrounding materials, ensure they are non-flammable and maintain a minimum distance of 1000 mm from the fireplace where applicable.
Installation Type Overview
Diagram Description: Four scenarios are depicted, showing the Planika Senso Fireplace integrated into different wall configurations, often with a television mounted above. Each scenario indicates a minimum clearance of 750mm between the fireplace and the TV.
- Single Sided: Standard wall installation.
- Left/Right Corner: Installation in a corner wall.
- Three Sided: Installation with three visible sides.
- All Type: Illustrates a configuration without a deflector.