Turbine Flowmeter User Handbook ?v=1716920774
Manual de operación Turbinas
TURBINE FLOWMETER USER MANUAL TA, TB AND TC
GUADARRAMA FLOW
Flowmeters and flow measurement technologies. Excellence in precision and repeatability. Made in Spain since 1972.
1

Manual de operación Turbinas
Index
VERY IMPORTANT.....................................................................................................................................ii 1. General information ........................................................................................................................ 3
1.1. Measuring principle................................................................................................................. 3 2. Equipment Description.................................................................................................................... 4
2.1. Description and dimensions of the turbine flowmeters ......................................................... 4 2.1.1. TA Model ......................................................................................................................... 4 2.1.2. TB Model ......................................................................................................................... 5 2.1.3. TC Model ......................................................................................................................... 6
2.2. Transmitters ............................................................................................................................ 7 3. Installation....................................................................................................................................... 8
3.1. Mechanical installation ........................................................................................................... 8 3.1.1. Laminar Flow ................................................................................................................... 8 3.1.2. Always with liquid.......................................................................................................... 10 3.1.3. Avoid air passage........................................................................................................... 10 3.1.4. Other recommendations ............................................................................................... 10
4. Electrical connection ..................................................................................................................... 11 4.1. CEB01C Transmitter............................................................................................................... 11 4.1.1. NPN ­ PNP open collector pulse output........................................................................ 11 4.2. CEB01MA transmitter............................................................................................................ 12 4.2.1. 4 ­ 20 mA analog output. .............................................................................................. 12
5. Contact .......................................................................................................................................... 13
i

Turbine Flowmeter User Manual
VERY IMPORTANT
MECHANICAL INSTALLATION · A FILTER between 0.5 - 1 mm (0.02 ­ 0.04 in) mesh must be installed in front of the flowmeter to protect it. Failure to install this filter can cause major damage to the equipment. This filter must be installed following the minimum flow meter inlet length indications to maintain laminar flow. · The indications described in the user manual must be followed.
ELECTRICAL INSTALLATION. Only for models with power supply with pulse output. · The power supply supplying voltage to the flowmeter: o It must not exceed 30 Vdc or be less than 12 Vdc. o It must not supply INDUCTIVE LOADS (Coils, solenoid valves, contactors, etc.). · The polarity of the power supply cannot be reversed. · The pulse output does not support loads greater than 100 mA. · Power cables (Greater than 110 Vac) and Data (Pulse, analog, etc.) must go through separate conduits.
These turbine flowmeters have a magnetic pulse sensor to collect the rotation of each blade of the propeller inside the measuring tube. If the flowmeter has a strong electromagnetic field nearby that comes from an electric motor or other element such as a transformer, the pulse pickup may be influenced by this electromagnetic field. The pulse cable must go through signal channeling, never power and this must be shielded with one end of this mesh to ground. Nor can the excess cable be wound making a coil. The fluid cannot carry air, since the flow meter would measure this air and the liquid.
ii

1. General information

Manual de operación Turbinas

1.1. Measuring principle
Turbine flowmeters are equipped with a propeller that rotates when the flow circulates inside it. The rotation speed is proportional to the flow rate, so once the speed is known, the flow rate can be determined. To know this, a sensor is used that generates a pulse every time a propeller blade passes in front of it. In this way, a train of pulses is obtained whose frequency allows the flow rate to be determined.

3

2. Equipment Description

Turbine Flowmeter User Manual

2.1. Description and dimensions of the turbine flowmeters 2.1.1. TA Model

Data sheet in Metric Units

Model

Temperature (°C)
Min. Max.

Pressure (bar)
Maximum

Flow Rate (L/h)
Min. Max.

Standard Resolution
Pulses/liter (approx.)

Materials

Impeller

Body

Connections

Dimensions (mm)

Weight (kg)

Clamp Connection

B

A

C Standard

CEB01C CEB01MA CEB09BV/SI/SIA

TA15 -30 90 40 300 3.000 1.000 AISI 2205 AISI 316 DN15 144 135 110

190

34 1

Data sheet in US Units

Model

Temperature (°F)
Min Max.

Pressure (psi)
Maximum

Flow Rate (GPH)
Min. Max.

Standard Resolution
Pulses/Gallon (approx.)

Materials

Impeller

Body

Connections
Clamp Connection

TA15 -22 194 580 79 790 3,785 AISI 2205 AISI 316

½"

A
5.67

Dimensions (in)

B

CEB01C CEB01MA CEB09BV/SI/SIA

5.31 4.33

7.48

C
1.34

Weight (lb)
Standard
2

4

2.1.2. TB Model

Turbine Flowmeter User Manual

Data sheet in Metric Units

Temperature Pressure

(°C)

(bar)

Flow Rate (L/h)

Standard Resolution

Model

Materials

Connections

Min. Max. Maximum Min.

Max.

Pulses/liter (approx.)

Impeller

Body

Flanges

EN-1092-1 Flanges

A

TB32 30 90 40 1.000 12.000 150

AISI AISI AISI 2205 316 304

DN32 PN-40

200

TB40 30 90 40 2.000 20.000 69

AISI AISI AISI 2205 316 304

DN40 PN-40

200

TB50 30 90 40 3.000 40.000 31

AISI AISI AISI 2205 316 316

DN50 PN-40

200

TB80 30 90 40 5.000 100.000 11

AISI AISI AISI 2205 316 304

DN80 PN-40

200

Dimensions (mm)

CEB01C

B CEB01MA CEB09BV/SI/SIA

Weight (kg)
Standard

140 115

195

5

145 120

200

7

150 125

205

9

165 140

220

15

Data sheet in US Units

Temperature Pressure

(°F)

(psi)

Model

Flow Rate (GPH)

Standard Resolution

Materials

Connections

Min. Max. Maximum Min.

Max.

Pulses/Gallon (approx.)

Impeller

Body

Flanges

EN-1092-1 Flanges

A

TB32 -22 194 580 264 3,170

568

AISI AISI AISI 2205 316 304

1 ¼" PN-40

7.87

TB40 -22 194 580 528 5,280

261

AISI AISI AISI 2205 316 304

1 ½" PN-40

7.87

TB50 -22 194 580 972 10,567 117

AISI AISI AISI 2205 316 316

2" PN-40

7.87

TB80 -22 194 580 1,321 26,417 42

AISI AISI AISI 2205 316 304

3" PN-40

7.87

Dimensions (in)

CEB01C

B CEB01MA CEB09BV/SI/SIA

Weight (lb)
Standard

5.51 4.53

7.68

11

5.71 4.72

7.87

15

5.91 4.92

8.07

20

6.50 5.51

8.66

33

5

2.1.3. TC Model

Turbine Flowmeter User Manual

Data sheet in Metric Units

Model

Temperature (°C)
Min. Max.

Pressure (bar)
Maximum

TC25 30 90 40

TC32 30 90 40

TC40 30 90 40

TC50 30 90 25

TC80 30 90 25

Flow Rate (L/h)

Min.

Max.

800 8.000

1.000 12.000

2.000 20.000

3.000 40.000

5.000 100.000

Standard Resolution
Pulses/liter (approx.)
230
150
69
31
11

Materials
Impeller Body
AISI AISI 2205 316 AISI AISI 2205 316 AISI AISI 2205 316 AISI AISI 2205 316 AISI AISI 2205 316

Connections

DIN 11851 Sanitary Thread

A

DN25 200

DN32 200

DN40 200

DN50 200

DN80 200

Dimensions (mm)

CEB01C

B CEB01MA CEB09BV/SI/SIA

Weight (kg)
Standard

135 110

190

2

140 115

195

3

145 120

200

3

150 125

205

4

165 140

220

5

Data sheet in US Units

Model

Temperature (°F)
Min. Max.

Pressure (psi)
Maximum

TC25 -22 194 580

TC32 -22 194 580

TC40 -22 194 580

TC50 -22 194 362

TC80 -22 194 362

Flow Rate (GPH)

Min.

Max.

211 2,110

264 3,170

528 5,280

972 10,567

1,321 26,417

Standard Resolution
Pulses/Gallon (approx.)
870
568
261
117
42

Materials
Impeller Body
AISI AISI 2205 316 AISI AISI 2205 316 AISI AISI 2205 316 AISI AISI 2205 316 AISI AISI 2205 316

Connections

DIN 11851 Sanitary Thread

A

DN 1" 7.87

Dimensions (in)

CEB01C

B CEB01MA CEB09BV/SI/SIA

Weight (lb)
Standard

5.31 4.33

7.48

5

DN 1 ¼" 7.87 5.51 4.53

7.68

7

DN 1 ½" 7.87 5.71 4.72

7.87

7

DN 2" 7.87 5.91 4.92

8.07

9

DN 3" 7.87 6.50 5.51

8.66

11

6

Turbine Flowmeter User Manual
2.2. Transmitters
Transmitters are electronic devices that are used to calculate, using the pulses/liter factor, the volume of liquid that passes through the Turbine flowmeter. Depending on the model chosen, there is the option of having local indication (display), pulse output, analog output, or all combined.

CEB01C

CEB01MA

CEB09 (BV/BVSI/BVSIA)

- CEB01C: NPN ­ PNP transistor output, without local indication. - CEB01MA: Analog (4 ­ 20 mA) output, without local indication. - CEB09BV: Local Indication of:
o Total Volume: Total liters that have passed through the equipment since the beginning of its operation, with a resolution of 8 digits.
o Partial Volume: Total liters that have passed through the equipment since the last reset, with a resolution of 7 digits.
o Volumetric Flow: Instantaneous flow rate that circulates through the flowmeter, with a resolution of 5 digits.
- CEB09BVSI: Local indication and NPN ­ PNP transistor output. - CEB09BVSIA: Local indication, NPN ­ PNP transistor and analog (4 ­ 20 mA) output.

Model

Power

Output

Supply Indication Pulses 4 ­ 20 mA

Material

Description

CEB01C CEB01MA

24 Vdc 24 Vdc

X

Aluminum

NPN - PNP transistor output, without local indication

X

Stainless Steel

4 ­ 20 mA output, without local indication

CEB09BV Internal X

Aluminum

Local Indication, without outputs

CEB09BVSI Internal X

X

Aluminum

NPN ­ PNP transistor output and local indication

CEB09BVSIA 24 Vdc

X

X

X

Aluminum NPN ­ PNP transistor and 4 ­ 20 mA output and local indication

Note: CEB09BV/SI/SIA transmitters have a specific user manual.
7

3. Installation

Turbine Flowmeter User Manual

3.1. Mechanical installation
Stainless steel turbine flowmeters accurately measure when correct mechanical installation is performed. The recommendations that are exposed in this section, try to achieve the following objectives:
· Laminar flow: The liquid that passes through the equipment must do so in a laminar regime, that is, not turbulent.
· Always with liquid: The flowmeter must always be filled with liquid. · Avoid the passage of air: The passage of air, or other gas through the flowmeter must be
avoided.
Caution: A 0.5 ­ 1 mm (0.02 ­ 0.04 in) mesh FILTER must be installed in front of the flowmeter to protect it. Failure to install this filter can cause major damage to the equipment. This filter must be installed following the minimum flow meter inlet length indications to maintain laminar flow.

3.1.1. Laminar Flow
Straight sections. It is essential to place a section of straight pipe with the same internal diameter as that of the flow meter and, as a general rule, with a minimum length of 5 times the diameter at the outlet and 10 times the diameter at the inlet.

Reductions. If the diameter of the pipe is different from that of the flowmeter, concentric reductions must be placed before and after the indicated straight sections.
Curved sections. In front of or behind these straight tubes other elements or curved sections can be placed.
8

Turbine Flowmeter User Manual
Valves. Manual valves must be placed behind the flow meter. If you want to put them in front of it, you have to increase the straight section to 30 D. This is because, if a valve is left half open, the laminar flow of the liquid is greatly altered.
Unions with the pipe. The unions of the flowmeter with the pipes are critical points where turbulence can occur, affecting the precision of the equipment, if they are not carried out properly.
· As already indicated, the internal diameter of the pipe must be equal to that of the flow meter. · Furthermore, the union fitting and gasket must not disturb the flow of the liquid. This point
may be particularly important in the case of flanged junction TB turbine flowmeters. Gasket
1 - Inner diameter of gasket and flange 2 - Internal diameter of flowmeter 3 - Internal diameter of the pipe
It is very important that the gasket is centered and that it has the same internal diameter to avoid turbulence at the inlet of the flowmeter. It is recommended to use self-centering gaskets such as:
· Gaskets whose outside diameter rests on the inside of the bolts. · Gaskets with dimensions equal to the flanges, including their holes.
9

Turbine Flowmeter User Manual 3.1.2. Always with liquid The flow meter can be mounted in the pipeline in a VERTICAL or HORIZONTAL POSITION, but it must always be avoided that the flow meter can remain empty. A flowmeter should never be installed in an open discharge.
3.1.3. Avoid air passage The passage of air or any gas through the flowmeter must be avoided, otherwise a measurement error would be made. If it cannot be avoided, a degasser or any other system must be installed that prevents air from passing through the equipment. In mobile installations, the air hose must be purged before reaching the flow meter. Important. The passage of compressed air, steam or any other gas under pressure can seriously damage the turbine flow meter.
3.1.4. Other recommendations The flow meter must not be mounted next to the electric motor of a pump. It must be moved a minimum of 50 cm away. The fluid should not back up, otherwise it would count it positively. If there is a risk that this circumstance could occur, a non-return valve must be fitted. In lines with very hot liquids, if the flowmeter is installed in a horizontal line, rotate it 90 degrees so that the transmitter is not above the pipe, as the internal electronics could overheat.
10

4. Electrical connection

Turbine Flowmeter User Manual

4.1. CEB01C Transmitter 4.1.1. NPN ­ PNP open collector pulse output
PNP Connection

NPN Connection

11

4.2. CEB01MA transmitter 4.2.1. 4 ­ 20 mA analog output.
CEB01MA

Turbine Flowmeter User Manual

· Passive 4 ­ 20 mA output · Maximum load: 500 ohms

12

Turbine Flowmeter User Manual

5. Contact
For any problem you may encounter or service you need, do not hesitate to contact the G - Flow offices.

Telephone:

+34 916378174 / +34 916378175

E-mail:

serviciotecnico@g-flow.com

Address:

Office Laboratory Factory

Calle Justina Velasco Martín 2, Pol. Ind. Los Llanos 28260 ­ Galapagar ­ Madrid.

13



References

Microsoft Word for Microsoft 365