Lucky Miner LV07 Product Manual
1. Specification
| Product Glance | Value |
|---|---|
| Model | LV07 |
| Version | V1.0.0 |
| Crypto algorithm/coins | SHA256 |
| Typical hashrate, GH/s | 1000±10% |
| Power on @25°C, Watt | 25±10% |
| Detailed Characteristics | |
|---|---|
| Power supply | Value |
| Power supply AC input voltage range, V | 100~240V AC |
| Power supply AC input frequency range, Hz | 50/60 |
| Power supply AC input current, A | 0.6 |
| Adapted AC output power requirement, W | 60 |
| Hardware configuration | Value |
|---|---|
| Networking connection mode | WiFi 2.4G/Hotspot |
| Server size (Length*Width*Height, w/o package), mm | 109*99*45 |
| Server size (Length*Width*Height, with package), mm | 200*180*65 |
| Net weight, g | 370 |
| Gross weight, g | 950 |
| Noise, dBA @25°C | 38 |
| Environment requirements | Value |
|---|---|
| Operation temperature, °C | 0~30 |
| Storage temperature, °C | -20~70 |
| Operation humidity, RH | 10%~90% |
| Operation altitude, m | ≤2000 |
2. Conditions for using "Luckyminer LV07"
2.1 Power Requirements: Ensure the device is connected to a stable power source and meets the corresponding voltage and power requirements.
2.2 Environmental Conditions: It is recommended to use the device in a dry, well-ventilated environment to avoid overheating or moisture.
- 2.2.1 Good ventilation.
- 2.2.2 It is prohibited to stack multiple devices or place them close together.
- 2.2.3 Do not place the device in a confined space.
2.3 Temperature Range: Operate within ≤30°C to ensure device stability and performance.
2.4 Equipment heat dissipation:
- 2.4.1 Ensure smooth ventilation at the air inlet and outlet of the device.
- 2.4.2 Blocking the air inlet and outlet of the device is strictly prohibited.
2.5 Network Connection: Ensure the device is properly connected to the network and compatible with the selected mining pool protocol.
2.6 Maintenance: Regularly clean the device and pay attention to maintaining the cooling system to ensure proper operation.
2.7 Usage Restrictions:
- 2.7.1 Avoid using the device in excessively harsh environmental conditions and adhere to manufacturer's recommendations and warnings to maintain long-term stability.
- 2.7.2 It is prohibited to upgrade to unofficial firmware. No after-sales service will be provided when upgrading firmware under unofficial guidance.
3. Recommended parameters
- 3.1 Frequency: ≤575MHz, when the power consumption is >32W, please gradually reduce the frequency.
- 3.2 Core voltage: ≤1300mV, when the power consumption is >32W, please gradually reduce the voltage.
4. Mining Mode
| Mining mode | Mechanism description |
|---|---|
| SOLO | SOLO mining means mining cryptocurrency alone, earning full rewards upon discovering new blocks. |
| PPLNS | PPLNS mining refers to a payment model where miners' rewards are calculated based on their last N submitted valid shares. |
| P2P | P2P mining refers to mining directly within the blockchain network by connecting to other nodes, rather than using centralized mining pools. |
| PPS | PPS mining refers to a payment model where miners receive rewards based on the number of valid shares they submit. |
5. Mineable projects
| Item | Project Name | Reference mining pools Pool 1 | Pool 2 | Pool 3 |
|---|---|---|---|---|
| 1 | BTC | pool.vkbit.com:3333 | public-pool.io:21496 | btc.viabtc.io:3333 |
| 2 | BCH | p2p-spb.xyz:9338 | Solo-bch.2miners.com:9090 | www.viabtc.com:3333 |
| 3 | BSV | bsv.gorillapool.io:3333 | europe.mining-dutch.nl:4014 | |
| 4 | DGB | pool4ever.com:5109 | pool.dgb256.online:8080 | p2p-spb.xyz:5027 |
| 5 | XEC | hashpool.live:10043 | xec.luckymonster.pro:9113 | mining.viabtc.io:3014 |
| 6 | RBL | mining4people.com:4181 | afinepool.xyz:4931 | pool4ever.com:5014 |
| 7 | BTCP | na.mining4people.com:3452 | 82.137.50.129:3420 | btcp.mr-miner.org:5448 |
| 8 | BIT | 38.242.200.177:4611 | 103.230.158.177:50114 | 54.39.49.96:3442 |
| 9 | AUR | p2p-spb.xyz:12349 | pool4ever.com:5115 | valhala.is:3730 |
| 10 | WCN | pool4ever.com:5112 | na.mining4people.com:3334 | 103.249.70.25:4369 |
| 11 | PPC | pool4ever.com:5010 | solo.1pool.org:4004 | kriptokyng.com:3312 |
| 12 | RVB | connect.reversedbitcoin.org:11300 | zeusminingpool.com:5110 | na.mining4people.com:3415 |
| 13 | ACG | pool4ever.com:5140 | mining-pool.zapto.org:3450 | |
| 14 | LCC | sha256.na.mine.zergpool.com:3333 | us-stratum.coinminerz.com:3310 | p2p-spb.xyz:5555 |
| 15 | GLT | au.merged.stratum.cminors-pool.com:58900 | pool.cryptopowered.club:1064 | |
| 16 | X1C | Mining4people:3355 | poolkh.com:4468 |
Notes:
- LV07 is applicable to all SHA256 algorithm projects.
- For more mining pools, please refer to https://miningpoolstats.stream/bitcoin.
- Due to regional and mining pool access difficulties, LV07 cannot access all mining pools.
6. Operating instructions
6.1 Product list
- 6.1.1 LV07 miner * 1
- 6.1.2 Adapter(12V/5A, 100-240V Input) *1
- 6.1.3 AC line *1
6.2 Power on
- 6.2.1 Connect the AC cable to the adapter Input.
- 6.2.2 Connect adapter output to miner DC port.
- 6.2.3 After power on, the adapter indicator light is green, the miner fan is running, and the miner screen displays "connect to ssid: Lucky_ ****".
6.3 Connect to network
- 6.3.1 Search for the miner hotspot "Lucky_ ****" through WiFi on your phone or computer.
- 6.3.2 Select the "Lucky_ ****" hotspot (mobile or computer).
- 6.3.3 Wait for 5-10 seconds, automatically redirect to the mining configuration interface.
6.4 Mining configuration
- 6.4.1 Enter the settings interface in 6.3.3 or by entering the IP in the browser.
- 6.4.2 Explanation of Setting Interface:
| No. | Setting items | Explanation |
|---|---|---|
| 1 | WiFi SSID | WiFi name (special characters are strictly prohibited) |
| 2 | WiFi Password | WiFi password (special characters are strictly prohibited) |
| 3 | Stratum URL | Mining pool address or IP address |
| 4 | Stratum Port | Mining pool port number (multiple ports in the same mining pool correspond to different difficulties) |
| 5 | Stratum User | Registered username or main network wallet address for the mining pool |
| 6 | Frequency | ASIC IC operating Frequency (500-575MHz) |
| 7 | Core Voltage | ASIC IC core voltage(1200-1300mV) |
- 6.4.3 Settings completed, click the "Save" button.
- 6.4.4 After saving the settings, click the "Restart" button.
6.5 View running status
- 6.5.1 Restart completed, wait for 30-60 seconds, the Home page will display the real-time running status of the miner. Contains information such as "Overview", "Power", "Pool information", "Results", etc.
- 6.5.2 The miner screen will synchronously scroll to display the above information.
6.6 View the status of pool
- 6.6.1 Log in to the mining pool website or app used by Miner.
- 6.6.2 Check online device status through username or wallet address.
7. FAQ for Luckyminer LV07
| No. | Fault Description | Fault pictures | Possible causes | Solution | Solving diagram |
|---|---|---|---|---|---|
| 1 | Miner is powered on but cannot connect to WiFi | Connecting to ssid: xsl_hi Configuration SSID: Lucky_FD89 | Using non 2.4G WiFi | Check WiFi type, must use 2.4G WiFi (Router/Hotspot) | WiFi SSID: xsl_h1 WiFi Password: xiaoqiang |
| WiFi name or password has special characters | WiFi name and password must be in English/numbers, or a combination of English and numbers. | ||||
| The control IC is not started | When powered on, press the reset button to reset the main control chip (1-3 times). | ![]() | |||
| 2 | Miner is powered on, the screen and fan do not work. | [Image of miner screen] | Power adapter output does not match. | Measure whether the adapter output voltage is 12V±3%. If it is not 12V±3%, replace the adapter. | [Image of multimeter measuring voltage] |
| 3 | Miner is powered on, the screen does not light up and the fan works. | [Image of miner screen] | The control IC is not started | When powered on, press the reset button to reset the main control chip (1-3 times). | ![]() |
| 4 | The adapter light does not light up or keeps flashing. | [Image of adapter light] | The adapter does not output or the output is unstable. | Replace adapter. | |
| 5 | WiFi, Power consumption is normal, hash value is 0. | Power: 22.4W, Input Voltage: 12V, ASIC Voltage Requested: 1.25V Heat: ASIC Temperature 59C, Fan 6163 Performance: ASIC Frequency 575Mhz, ASIC Voltage 1.24V | Mining pool address | Check the mining pool address carefully and query mining pool related information: https://miningpoolstats.stream/bitcoin | |
| Port number | There may be multiple port numbers in the same mining pool. Generally, different port numbers correspond to the difficulty of access. Please choose the appropriate port number. | Stratum Port: 3014 | |||
| Mining pool difficulty | All mining pools have a minimum access difficulty. Please ensure that the device computing power is below the mining pool access difficulty. Experience value: 500G can access a mining pool with difficulty <1000 (port number). | Pool Default Difficulty: 1024 Pool Minimum Difficulty: 256 | |||
| Wallet address | You must use the mainnet wallet address of the currency being mined. For example: the BTC mainnet address generally starts with 1/3/bc1. | Stratum User: bc1qsn80udljur00zn58eg7y7 | |||
| 6 | Miner runs with low power consumption, <5W | Username | Some mining pools require a registered account to use. For this kind of mining pool, you need to fill in the miner name of the mining pool during configuration. | Stratum User: super66.0x0x19 | |
| 7 | Successfully connected to WiFi, miner restarted repeatedly. | Ghe: 1007.0 W/Th: 2 A/R: 74/8 UT: 0d 0h 5m IP: 10.0.0.5 | Mining pool resolution failed | Change mining pool. | ![]() |
| 8 | Miner keeps restarting and the Hashrate is unstable. | [Image of hashrate graph] | WiFi congestion and instability. | Change to a stable WiFi or hotspot. | |
| Mining pools are regulated. | Change to a locally allowed mining pool or a well-known mining pool. | ||||
| High power consumption, high temperature, highland temperature protection. | The environment temperature is <30℃, the equipment should be placed in a well-ventilated place. |
7. Global community communication group
[QR Code Image: LuckyMiner Taiwan Official Community]
LuckyMiner台灣區官方社群
FCC Compliance Information
FCC Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.