User Manual for SUN GOLD POWER models including: SPH8K48SP, SPH10K48SP, SPH8K48SP SUNGOLDPOWER 8000W DC 48V Pure Sine Wave Solar Inverter, 8000W DC 48V Pure Sine Wave Solar Inverter, Sine Wave Solar Inverter, Solar Inverter, Inverter
SUNGOLDPOWER 8000W DC 48V Pure Sine Wave Solar Inverter, Built-in 2 MPPT Solar Controllers, Max. 180A Battery Charging, AC Input/Output 120V/240V(settable) Inverter Charger (8000W DC 48V) : Patio, Lawn & Garden
8KW Hybrid Solar Inverter Pure Sine Wave Inverter for Home UL1741 Standard - SunGoldPower
User Manual - SunGoldPower
File Info : application/pdf, 41 Pages, 2.59MB
DocumentDocumentSun Gold Power Inc www.sungoldpower.com USER MANUAL All-in-one solar charge inverter SPH8K48SP SPH10K48SP All-in-one solar charge inverter V3.0 1 Sun Gold Power Inc www.sungoldpower.com Table of Contents 1. Safety............................................................................................................................................. 4 1.1How to use this manual............................................................................................................................... 4 1.2Symbols in this manual................................................................................................................................ 4 1.3Safety instructions ......................................................................................................................................... 4 2. Production Instructions .............................................................................................................. 5 2.1Instructions ...................................................................................................................................................... 5 2.2Features............................................................................................................................................................. 5 2.3System connection diagram ...................................................................................................................... 6 2.4Production Overview .................................................................................................................................... 7 3. Installation .................................................................................................................................... 8 3.1Select the mount location .......................................................................................................................... 8 3.2Mount the inverter ........................................................................................................................................ 9 3.3Remove the terminal protection cover and insect screen .............................................................. 9 4. Connection ..................................................................................................................................10 4.1Connection Overview .................................................................................................................................10 4.2Cable & circuit breaker requirement ....................................................................................................14 4.3AC input & output connection ...............................................................................................................16 4.4Battery Connection .....................................................................................................................................16 4.5PV connection...............................................................................................................................................17 4.6Dry contact connection .............................................................................................................................17 4.7Grounding connection...............................................................................................................................18 4.8Final assembly...............................................................................................................................................18 4.9Start up the inverter....................................................................................................................................18 5. Operation ....................................................................................................................................19 5.1Operation and display panel ...................................................................................................................19 5.2Setting.............................................................................................................................................................. 23 5.3AC output mode ..........................................................................................................................................29 5.4Battery charging mode..............................................................................................................................30 5.5Time-slot charging/discharging function ...........................................................................................31 5.6Battery parameter........................................................................................................................................32 6. Communication..........................................................................................................................34 6.1Overview .........................................................................................................................................................34 6.2USB-B port......................................................................................................................................................34 6.3WIFI port .........................................................................................................................................................35 All-in-one solar charge inverter V3.0 2 Sun Gold Power Inc www.sungoldpower.com 6.4CAN/RS485 port...........................................................................................................................................35 6.5Dry contact.....................................................................................................................................................36 7. FaultandRemedy ........................................................................................................................37 7.1Fault code.......................................................................................................................................................37 7.2Troubleshooting ........................................................................................................................................... 38 8. ProtectionandMaintenance......................................................................................................40 8.1Protection features......................................................................................................................................40 8.2Maintenance .................................................................................................................................................. 41 9. Datasheet ....................................................................................................................................42 All-in-one solar charge inverter V3.0 3 Sun Gold Power Inc 1. Safety www.sungoldpower.com 1.1How to use this manual · This manual contains important informationguidelinesoperation and maintenance for the following productsSPH series 8K48SP10K48SP · The manual must be followed during installation and maintenance. 1.2Symbols in this manual Symbol ! DANGER ! WARING ! CAUTION ! NOTICE Description DANGER indicates a hazardous situations which if not avoided will result in death or serious injury. WARING indicates a hazardous situations which if not avoided could result in death or serious injury. CAUTION indicates a hazardous situations which if not avoided could result in minor or moderate injury. NOTICE provide some tips on operation of products. 1.3Safety instructions ! DANGER · This chapter contains important safety instructions. Read and keep this manual for future reference. · Be sure to comply the local requirements and regulation to install this inverter. · Beware of high voltage. Please turn off the switch of each power sources before and during the installation to avoid electric shock. · For optimum operation of this inverter, please follow required specification to select appropriate cable size and necessary protective device. · Do not connect or disconnect any connections when the inverter is working. · Do not open the terminal cover when the inverter working. · Make sure the inverter is well grounding. · Never cause AC output and DC input short circuited. · Do not disassembly this unit, for all repair and maintenance, please take it to the professional service center. · Never charge a frozen battery. · Please keep children away from touching or mishandling the inverter. · Please make sure that this inverter is the only input power source for the load, do not use it in parallel with other input AC power sources to avoid damage. All-in-one solar charge inverter V3.0 4 Sun Gold Power Inc 2. Production Instructions www.sungoldpower.com 2.1Instructions SPH series is a new type of solar energy storage inverter control inverter integrating solar energy storage & utility charging and energy storage, AC sine wave output. It adopts DSP control and features high response speed, reliability, and industrial standard through an advanced control algorithm. Solar generation Battery charging Energy consumption Battery discharging time Utility charging Self consumption solar 2.2Features · Supports lead acid battery and li-ion battery connections. · With a dual activation function when the li-ion battery is dormant; either mains/photovoltaic power supply access can trigger the activation of the li-ion battery. · Support split-phase and single-phase pure sine wave output. · Supports four different voltage levels of 100Vac, 105Vac, 110Vac, and 120Vac per phase. · Supports two solar inputs and simultaneous tracking of two solar maximum power charging/carrying capacity functions. · Dual MPPT with 99.9% efficiency and maximum 22A current in a single circuit, perfectly adapted to high power modules. · 4 charging modes are available: solar only, mains priority, solar priority, and mixed mains/PV charging. · With the time-slot charging and discharging setting function, you can set the time period for cutting in/out of mains charging and switch the time period between battery discharging and mains bypass power supply mode. · Energy saving mode function to reduce no-load energy losses. · With two output modes of utility bypass and inverter output, with uninterrupted power supply function. · LCD large screen dynamic flow diagram design, easy to understand the system data and operation status. · 360° protection with complete short circuit protection, over current protection, over under voltage protection, overload protection, backfill protection, etc. · Support CAN, USB, and RS485 communication. All-in-one solar charge inverter V3.0 5 Sun Gold Power Inc www.sungoldpower.com 2.3System connection diagram The diagram below shows the system application scenario of this product. A complete system consists of the following components: · PV modules: converts light energy into DC energy, which can be used to charge the battery via an inverter or directly inverted into AC power to supply the load. · Utility grid or generator: connected to the AC input, it can supply the load and charge the battery at the same time. The system can also operate generally without the mains or generator when the battery and the PV module power the load. · Battery: The role of the battery is to ensure the regular power supply of the system load when the solar energy is insufficient and there is no mains power · Home load: Various household and office loads can be connected, including refrigerators, lamps, televisions, fans, air conditioners, and other AC loads. · Inverter: The energy conversion device of the whole system. The actual application scenario determines the specific system wiring method. All-in-one solar charge inverter V3.0 6 Sun Gold Power Inc 2.4Production Overview www.sungoldpower.com 1 LCD screen 2 4 ON/OFF Rocker Switch 5 7 BAT INPUT (-) 8 10 WIFI port 11 13 AC OUT (L+L+N) 14 LED Indicators PV INPUT (1/1) Dry contact USB-B port AC IN (L+L+N) 3 Touchable key 6 BAT INPUT (+) 9 RS485/CAN port 12 Grounding Screw 15 AC INPUT breaker All-in-one solar charge inverter V3.0 7 Sun Gold Power Inc 3. Installation www.sungoldpower.com 3.1Select the mount location SPH series are designed for INDOOR USE ONLY (IP20) . Please consider the followings before selecting the location · Choose the solid wall to install the inverter. · Mount the inverter at eye level. · Adequate heat dissipation space must be provided for the inverter. · The ambient temperature should be between -10~55 (14~131) to ensure optimal operation. ! DANGER · Do not install the inverter where highly flammable materials are near by. · Do not install the inverter in potential explosive areas. · Do not install the inverter with lead-acid batteries in a confined space. ! CAUTION · Do not install the inverter in direct sunlight. · Do not install or use the inverter in a humid environment. All-in-one solar charge inverter V3.0 8 Sun Gold Power Inc www.sungoldpower.com 3.2Mount the inverter Make 4 mounting holes in the wall with an electric drill according to the specified dimensions, insert 2 expansion screws above and fix the inverter with 2 M5 screws below. 3.3Remove the terminal cover & anti insect net Using a screwdriver, remove the terminal protection cover and anti insect net. ! NOTICE When using the device in areas with poor air quality, the dust screen is easily blocked by airborne particles. Please dismantle and clean the dust screen regularly to avoid affecting the internal air flow rate of the inverter, which may trigger an over-temperature protection fault (19/20 fault) affecting the use of the power supply and the service life of the inverter. All-in-one solar charge inverter V3.0 9 Sun Gold Power Inc 4. Connection 4.1Connection Overview · Split-phase modedefault AC output www.sungoldpower.com Items Applicable Model Output Voltage Range (L-N) Output Voltage Range (L-L) · Single-phase mode AC output Description SPH series 100120Vac, 120Vac default 200240Vac240Vac default L1&L2 in parallel connection Items Applicable Model Output Voltage Range (L-N) Description SPH series 100120Vac, 120Vac default ! NOTICE · Users can change the output phase mode and output voltage by setup menu. Please read the chapter 5.2 Setting. · Output phase mode corresponds parameter 39 , when option is 180 indicates split-phase, when option is 0 indicates single-phase. · Output voltage corresponds parameter 38 , the output voltage can be set from 100V to 120V. All-in-one solar charge inverter V3.0 10 Sun Gold Power Inc Split-phase Mode www.sungoldpower.com Notice The open circuit voltage of PV panel in series connection must below 500V , Over-voltage will cause damage to the inverter. Damage caused by improper conffguration is not covered by warranty. Single-phase Mode All-in-one solar charge inverter V3.0 Notice The open circuit voltage of PV panel in series connection must below 500V , Over-voltage will cause damage to the inverter. Damage caused by improper conffguration is not covered by warranty. 13 Sun Gold Power Inc www.sungoldpower.com 4.2Cable & circuit breaker requirement · PV INPUT Model Cable Diameter Max.PV Input Current Circuit Breaker Spec SPH8K48SP 5mm²/ 10 AWG 22A 2P-25A SPH10K48SP 5mm²/ 10 AWG 22A 2P-25A · AC INPUT Model Output Mode Diagram Max.Input Current Cable diameter Split-phase L1 L2 63A(L1/L2/N) N 13mm2/6AWG (L1\L2\N) Circuit Breaker Spec 3P-63A SPH8K48SP Single-phase 63A(L1/L2) 126A(N) 13mm2/6AWG(L1/L2) 26mm2/3AWG(N) L1 and L2 in same phase Split-phase 63A(L1/L2/N) L1 L2 N 13mm2/6AWG (L1\L2\N) 2P-125A 3P-63A SPH10K48SP Single-phase 63A(L1/L2) 126A(N) 13mm2/6AWG(L1/L2) 26mm2/3AWG(N) L1 and L2 in same phase 2P-125A · BATTERY Model SPH8K48SP SPH10K48SP Cable Diameter 34mm²/ 2 AWG 42mm²/ 1 AWG All-in-one solar charge inverter V3.0 Max.Battery Current 180A 220A Circuit Breaker Spec 2P-200A 2P-250A 14 Sun Gold Power Inc · AC OUTPUT www.sungoldpower.com Model Output Mode Diagram Max.Output Current Cable diameter Circuit Breaker Spec Split-phase L1 L2 42A (L1/L2/N) 13mm2/6AWG (L1\L2\N) N 3P-63A SPH8K48SP Single-phase Split-phase L1 and L2 in same phase L1 L2 N 42A (L1/L2) 84A(N) 13mm2/6AWG(L1\ L2) 26mm2/3AWG(N) 13mm2/6AWG(L1\ 63A (L1/L2/N) L2\N) 2P-125A 3P-63A SPH10K48SP Single-phase 63A (L1/L2) 126A(N) L1 and L2 in same phase 13mm2/6AWG (L1\L2) 26mm2/3AWG(N) 2P-125A ! NOTICE · PV INPUTAC INPUTAC OUTPUT 1. Use a stripper to remove the 6~8mm insulation of the cable. 2. Fixing a ferrule at the end of the cable. (ferrule needs to be prepared by the user) · BATTERY 1. Use a stripper to remove the 6~8mm insulation of the cable 2. Fixing cable lugs that supply with the box at the end of the cable. The wire diameter is for reference only. If the distance between the PV array and the inverter or between the inverter and the battery is long, using a thicker wire will reduce the voltage drop and improve the performance of the system. All-in-one solar charge inverter V3.0 15 Sun Gold Power Inc www.sungoldpower.com 4.3AC input & output connection Connect the live,neutral and ground wires according to the cables' position and order shown in the diagram below. ! DANGER · Before connecting AC inputs and outputs, the circuit breaker must be opened to avoid the risk of electric shock and must not be operated with electricity. · Please check that the cable used is sufficient for the requirements, too thin, poor quality cables are a serious safety hazard. 4.4Battery Connection Connect the positive and negative cable of the battery according to the diagram below. ! DANGER · Before connecting battery, the circuit breaker must be opened to avoid the risk of electric shock and must not be operated with electricity. · Make sure that the positive and negative terminals of the battery are connected correctly and not reversed, otherwise the inverter may be damaged. · Please check that the cable used is sufficient for the requirements, too thin, poor quality cables are a serious safety hazard. All-in-one solar charge inverter V3.0 16 Sun Gold Power Inc 4.5PV connection www.sungoldpower.com Connect the positive and negative wires of the two strings of PV according to the diagram below. ! DANGER · Before connecting PV, the circuit breaker must be opened to avoid the risk of electric shock and must not be operated with electricity. · Please make sure that the open circuit voltage of the PV modules in series does not exceed the Max.OpenCircuitVoltage of the inverter (In the SPH series, this value is 500V), otherwise the inverter may be damaged. 4.6Dry contact connection Use a small screwdriver to push back the direction indicated by the arrow, then insert the communication cable into the dry junction port. (Communication cable diameter 0.2~1.5mm²) All-in-one solar charge inverter V3.0 17 Sun Gold Power Inc 4.7Grounding connection Please make sure the grounding terminal connect to the Grounding Bar. www.sungoldpower.com ! NOTICE · The grounding cable should have a diameter of not less than 4 mm² and be as close as possible to the grounding point. 4.8Final assembly After ensuring that the wiring is reliable and the wire sequence is correct, install the terminal protection cover in place. 4.9Start up the inverter · Step 1 : Close the circuit breaker of the battery. · Step 2Press the rocker switch on the bottom of inverter, the screen and indicators light up to indicate that the inverter has been activated. · Step 3Sequential close of the circuit breakers for PV, AC input and AC output. · Step 4Start the loads one by one in order of power from small to large. All-in-one solar charge inverter V3.0 18 Sun Gold Power Inc www.sungoldpower.com 5. Operation 5.1Operation and display panel The operation and display panel below includes 1 LCD screen, 3 indicators, 4 touchable keys. · Touchable Keys Touchable Keys Description To enter/exit the setting menu To next selection To last selection To confirm/enter the selection in setting menu · LED Indicators Indicators FAULT CHARGE AC/INV Color Red Green Yellow Description Flash: error occur Continued: charging complete Flash: charging Continued: utility grid by-pass output Flash: inverter output All-in-one solar charge inverter V3.0 19 Sun Gold Power Inc · Display panel www.sungoldpower.com Icon Description Indicates the PV panel Icon Indicates the battery Indicates the inverter is workin Indicates the inverter is communicating with data collector Indicates the direction of energy flow Indicates the inverter is standby Indicates error occur Description Indicates the utility grid Indicates the generator Indicates the home load Indicates the buzzer muted Indicates the inverter is working normally Indicates setting All-in-one solar charge inverter V3.0 20 Sun Gold Power Inc www.sungoldpower.com Icon Description Indicates load power 80%~100% Indicates load power 60%~79% Indicates load power 40%~59% Indicates load power 20%~39% Indicates load power 5%~19% Indicates battery undervoltage Indicates over-load Indicates system communication erro Indicates system over-voltage Indicates system overtemperatur Indicates battery is full Indicates sealed lead-acid battery Indicates gel lead-acid battery Icon Description Indicates battery SOC 80%~100% Indicates battery SOC 60%~79% Indicates battery SOC 40%~59% Indicates battery SOC 20%~39% Indicates battery SOC 5%~19% Battery over discharge Indicates BMS fault Indicates system under-voltage Indicates system undertemperature Indicates system over-current Indicates user defined battery Indicates flooded lead-acid battery Indicates ternary li-ion battery Indicates LFP li-ion battery PV LOAD Indicates PV energy is carrying the load AC CHG Indicates AC IN energy is charging the battery BYPASS Indicates the inverter output mode is bypass BATT FIRST Indicates the inverter output mode is battery first ECO PV CHG MAIN FIRST SOLAR FIRST Indicates energy-saving mode Indicates PV energy is charging the battery Indicates the inverter output mode is mains power first Indicates the inverter output mode is solar first All-in-one solar charge inverter V3.0 21 Sun Gold Power Inc www.sungoldpower.com · View real-time data In the main screenpress the UP / DOWN keys to view the real-time data of the inverter during operation. ! NOTICE Main Screen UP/DOWN View Real-Time Data Page 1 2 3 PV side PV voltage PV current PV power BAT side Batt Voltage Batt Current Batt Voltage 4 PV today kWh Batt Current PV side heat sink 5 temperature INV Heat Sink Temperature 6 PV rated voltage Batt Rated Voltage Max.Batt charging 7 Max. PV charging current current 8 AC IN side AC in voltage LOAD side Single phase voltage General Current Time AC in current Single phase Current Total AC charging power Today AC charging kWh Single phase active power Single phase apparent power AC frequency AC output frequency Current Date PV Total kWh Load Total kWh RS485 Address Busbar voltage AC output rated power Max. AC charging Current / Total AC output active power Total AC output apparent power Soft Version / / All-in-one solar charge inverter V3.0 22 Sun Gold Power Inc 5.2Setting ! NOTICE www.sungoldpower.com UP/DOWN UP/DOWN Parameter option ID Parameter Meaning 00 Exit AC output source 01 priority 02 AC output frequency Options ESC UTI default SbU SOL 50.0 60.0 default Description Exit the setup menu. Utility at first priority, utility and solar provide power to load at the same time when solar is available, battery will provide power to load only when utility power is not available. Solar power and battery at first priority,Utility will provide power to load when solar power is not available and the battery voltage below parameter [04] value. Solar power at first priority, Utility will provide power to load when solar power is not available and the battery voltage below parameter [04] value . AC output frequency will adaptive utility frequency in bypass mode.Otherwise the output will follow the preset value. All-in-one solar charge inverter V3.0 23 Sun Gold Power Inc ID Parameter Meaning 03 AC input voltage range Voltage point of battery 04 switch to utility Voltage point of utility 05 switch to battery Options UPS default APL 43.6 default 56.8 default 06 Battery charging mode Battery charging 07 current 08 Battery type Battery bulk charging 09 voltage Battery bulk charging 10 delay time SNU default CUb CSO OSO 60 default USER SLd FLd GEL default L14/ L15/ L16 N13/ N14 57.6 default 120 default www.sungoldpower.com Description When output range is 120/110V, input voltage range 90~140V When output range is 100/105V, input voltage range 85~140V When parameter1= SBU=SOL, output source will switch to utility from battery when the battery voltage below the preset value. Setting range:40~60V When parameter 1=SBU/SOL, output source will switch to battery from utility when the battery voltage above the preset value. Range:40~60V Solar and utility charging the battery at the same time, solar at the first priority, utility power as a supplement when solar power is not sufficient.Notice: Solar and utility charging the battery at the same time only in bypass mode, only solar charging can be used when the invert circuit is in operation Utility is the first priority in charging, Solar charging the battery only when utility is not available. Solar is the first priority in charging, Utility charging the battery only when solar is not available Only solar charging the battery. SPH8K48SP current setting range:0~180A. SPH10K48SP current setting range:0~200A. User-defined, user can set all battery parameter. Sealed lead-acid battery. Flooded lead-acid battery. Gel lead-acid battery. LFP li-ion battery, L14\L15\L16 corresponds battery cells number in series. Ternary li-ion battery. Setting range:48V~58.4V, increment of each click is 0.4V, parameter can be set only when battery type is USER and L14/15/16,N13/14 Indicates the duration when battery voltage reached parameter 09 value in bulk charging procession,Setting range: 5min~900min, increment of each click is 5min, parameter can be set only when battery type is USER and L14/15/16,N13/14 All-in-one solar charge inverter V3.0 24 Sun Gold Power Inc ID Parameter Meaning Battery float charging 11 voltage Battery overdischarge 12 voltage (delay off Options 55.2 default 42 default Battery overdischarge 13 voltage delay time 5 default Battery undervoltage 14 alarm 44 default Battery undervoltage 15 limit voltag 40 default Battery equalization 16 charging Battery equalization 17 charging voltage Battery equalization 18 charging duration Battery equalization 19 charging delay time Battery equalization 20 charging interval Battery equalization 21 charging stop-start 22 Power saving mode All-in-one solar charge inverter V3.0 dIS ENA default 58 120 120 30 dIS default ENA dIS default ENA www.sungoldpower.com Description Setting range: 48V~58.4V, parameters cannot be set only after successful BMS communication. When the battery voltage falls below this voltage point and parameter 13 value is reached, the inverter output will be switched off.Setting range: 40V~48V, increment of each click is 0.4V, parameter can be set only when battery type is USER and L14/15/16,N13/14 Indicates the duration when battery voltage reached parameter 12 value in over-voltage procession. Setting range: 5s~50s, increment of each click is 5s, parameter can be set only when battery type is USER and LFP14/15/16,NCM13/14 When the battery voltage falls below this voltage point, alarm will be displayed on the screen and indicator. Setting range: 40V~52V, increment of each click is 0.4V, parameter can be set only when battery type is USER and L14/15/16,N13/14 When the battery voltage falls below this voltage point, the inverter output is switched off immediately. Setting range is 40V~52V, increment of each click is 0.4V, parameter can be set only when battery type is USER and L14/15/16,N13/14 Disable equalization charging. Enable equalization charging, parameter can be set only when battery type is FLd\SLd\USER Setting range: 48V~58V, increment of each click is 0.4V, parameter can be set only whenbattery type is FLd\SLd\USER Setting range: 5min~900min, increment of each click is 5min, parameter can be set only when battery type is FLd\SLd\USER Setting range: 5min~900min, increment of each click is 5min, parameter can be set only when battery type is FLd\SLd\USER Setting range: 0~30 days, increment of each click is 1 day, parameter can be set only when battery type is FLd\SLd\USER Stop equalization charging immediately. Start equalization charging immediately Disable power saving mode Enable power saving mode, When the load power below50W, the inverter output will switch off after a 5min delay . When the load is more than 50W, the inverter automatic restart 25 Sun Gold Power Inc www.sungoldpower.com ID Parameter Meaning 23 Over-load restart Over-temperature 24 restart 25 Buzzer alarm Power source switching 26 reminder Inverter overload switch 27 to bypass Max. utility charging 28 current Options dIS ENA default dIS ENA default dIS ENA default dIS ENA default dIS ENA default 60 default Description When overload occurs and the output is switched offthe machine will not restart. When overload occurs and the output is switched offthe machine will restart after a delay of 3 minutes. After it reaches 5 cumulative time, the machine will not restart automatically. When over temperature occurs and the output is switched offthe machine will not restart. When overload occurs and the output is switched offthe machine will restart when the temperature drops. Disable buzzer alarm. Enable buzzer alarm. Disable reminder when the status of the input power source changes. Enable reminder when the status of the input power source changes. Disable switch to the bypass when the inverter is overload Enable switch to the bypass when the inverter is overload. SPH8K48SP, setting range: 0~100A. SPH10K48SP, setting range: 0~120A. 30 RS485 address Id:1 RS485 address setting range: 1~254. SLA default Enabling PC and remote monitoring protocols 32 RS485 communication 485 Enabling BMS communication based on RS485 CAN Enabling BMS communication based on CAN When item 32 is set to 485 or CAN, the corresponding communication protocol must be selected in item 33 33 BMS communication PAC=PACERDA=RitarAOG=ALLGRAND BATTERYOLT=OLITER HWD=SUNWODA, DAQ=DAKING, WOW=SRNE, PYL=PYLONTECH UOL=WEILAN Feed back & hybrid 34 output function dIS default MIX LOD ON GRD Disable this function. When parameter 1=UTI ,the solar energy is prioritised to charge the batteries and any excess energy will be used to power the load. With an antibackflow function, the PV energy is not feed back into the grid. When parameter 1=UTI ,solar energy will feed back into the grid when battery is full or disconnected. Battery under voltage 35 52 recover point Battery full recharge 37 52 voltage point All-in-one solar charge inverter V3.0 Battery recover discharge from under voltage protection when voltage above this value. Setting range: 44V~54V. Inverter stops charging when the battery is full. Inverter resumes charging when the battery voltage below this value. Setting range: 44V~54V. 26 Sun Gold Power Inc ID Parameter Meaning 38 AC output voltage 40 1st slot start charging 41 1st slot end charging 42 2nd slot start charging 43 2nd slot end charging 44 3rd slot start charging 45 3rd slot end charging Time slot charging 46 function 1st slot start 47 discharging 48 1st slot end discharging 2nd slot start 49 discharging 2nd slot end 50 discharging 3rd slot start 51 discharging 52 3rd slot end discharging Time slot discharging 53 function 54 Local date 55 Local time 57 Stop charging current Options 120 00:00:00 00:00:00 00:00:00 00:00:00 00:00:00 00:00:00 dIS default ENA 00:00:00 00:00:00 00:00:00 00:00:00 00:00:00 00:00:00 dIS default ENA 00:00:00 00:00:00 2 www.sungoldpower.com Description Setting range: 100/105/110/120Vac Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Disable this function Enable this function, AC output source mode will switch to SBU, utility charging the battery and carry load only in charging time slot which user set or the battery is under voltage. Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Setting range: 00:00:00-23:59:00 Disable this function. Enable this function, AC output source mode will switch to UTI , battery discharging only in discharging time slot which user set or utility is not available. YY/MM/DD.Setting range: 00:01:01-99:12:31 Setting range: 00:00:00-23:59:59 Charging stops when the charging current is less than the set value (unit:amp) All-in-one solar charge inverter V3.0 27 Sun Gold Power Inc ID Parameter Meaning 58 Discharging alarm SOC 59 Discharging cutoff SOC 60 Charging cutoff SOC 61 Switching to utility SOC 62 Swithing to inverter SOC N-PE bonding automatic 63 switching function 68 AC output phase mode Options 15 5 100 10 100 dIS default ENA 0 180 default www.sungoldpower.com Description Triggers an alarm when the battery SOC is less than the set value (unit:%) Stops discharging when the battery SOC is less than the set value (unit:%) Stops charging when the battery SOC is touch the set value (unit:%) Switch to utility power when the battery SOC is less than this setting (unit:%) Switches to inverter output mode when SOC is greater than this setting (unit:%) Allow automatic switching of N-PE bonding Prohibit automatic switching of N-PE bondin 0 stands for single-phase mode. Assume parameter 38=120V.The phase difference of L1-L2 is 0 degree, L1/L2 in parallel connection, therefore L1-N/L2-N voltage is 120V.Setting allowed only when output is switched off. 180 stands for split-phase mode. Assume parameter 38=120V, The phase difference of L1-L2 is 180 degree, therefore L1-N/L2-N voltage is 120V, L1-L2 voltage is 120*2=240V.Setting allowed only when output is switched off. All-in-one solar charge inverter V3.0 28 Sun Gold Power Inc www.sungoldpower.com 5.3AC output mode The AC output mode corresponds to parameter setting item 01 and 34, which allows the user to set the AC output power source manually. · Utility Priority Output 01 UTI (default) Utility at first priority, utility and solar provide power to load at the same time when solar is available, battery will provide power to load only when utility power is not available.(Priority: utility>solar>battery) Utility Valid Utility Outage · Solar and Utility Hybrid Outpu 34 MIX LOD In UTI mode, when not connected to the battery or when the battery is full, the solar and the utility supply power to the load at the same time.(Priority: solar>utility>battery) Battery disconnected · Solar Priority Output 01 SOL Battery FullBattery Solar provides power to the loads as first priority.If solar is not sufficient or not available, the utility will be used as a supplement to provide power to the loads. This mode maximises solar energy while maintaining battery power and is suitable for areas with relatively stable power grids.(Priority: solar>utility>battery) Solar Sufficient Solar Insufficient · Inverter Priority Output 01 SbU Solar provides power to the loads as first priority.If solar is not sufficient or not available, the battery will be used as a supplement to provide power to the loads. When the battery voltage reaches the value of parameter 04 (Voltage point of battery switch to utility ) will switch to utility to provide power to the load, This model makes maximum use of DC energy and is used in areas where the grid is stable. (Priority: solar>battery>utility) Battery Available Battery Under-voltage All-in-one solar charge inverter V3.0 29 Sun Gold Power Inc 5.4Battery charging mode www.sungoldpower.com The charging mode corresponds to parameter setting item 06, which allows the user to set the charging mode manually. · Hybrid Charging SNU (default) Solar and utility charging the battery at the same time, solar at the first priority, utility power as a supplement when solar power is not sufficient. This is the fastest way to charge and is suitable for areas with low power supply, providing customers with sufficient back-up power.(Source priority: solar>utility) Solar Sufficient Solar Insufficient · Utility Priority Chargin CUb The utility power gives priority to charging the battery, and PV charging is only activated when the utility power is not available.(Source priority: utility>solar) Utility Valid Utility Outage · Solar Priority Charging CSO Solar priority charging, with utility charging only activated when the solar fails. By making full use of solar power during the day and switching to utility charging at night, battery power can be maintained and is suitable for applications in areas where the grid is relatively stable and electricity prices are more expensive.(Source priority: solar>utility) Solar Sufficient Solar Fails · Only Solar Chargin OSO Solar charging only, no mains charging is activated. This is the most energy-efficient method, with all the battery power coming from solar energy, and is usually used in areas with good radiation conditions. All-in-one solar charge inverter V3.0 30 Sun Gold Power Inc www.sungoldpower.com 5.5Time-slot charging/discharging function The SPH series is equipped with a time-slot charging and discharging function, which allows users to set different charging and discharging periods according to the local peak and valley tariffs, so that the utility power and PV energy can be used rationally. When mains electricity is expensive, the battery inverter is used to carry the load; when the mains electricity is cheap, the mains electricity is used to carry the load and charge, which can help customers to save electricity costs to the greatest extent. The user can turn on/off the time-slot charging/discharging function in setup menu parameter 46 and 53.and set charging and discharging slot in parameter 40-45, 47-52. Below are examples for users to understand the function. ! NOTICE Before using this function for the ffrst time, please set the local time in parameter items 54, 55, then the user can set the corresponding time slot according to the local peak and valley tariff charges. Time-slot Utility Charging/Carrying Function Time-slot Battery Disacharging Function With 3 definable periods, the user can freely set the mains charging/carrying time within the range of 00:00 to 23:59. During the time period set by the user, if PV energy is available, PV energy will be used first, and if PV energy is not available or insufficient, utility energy will be used as a supplement. All-in-one solar charge inverter V3.0 With 3 definable time periods, users can freely set the battery discharge time within the range of 00:00 to 23:59. During the time period set by the user, the inverter will give priority to the battery inverter to carry the load, and if the battery power is insufficient, the inverter will automatically switch to mains power to ensure stable operation of the load. 31 Sun Gold Power Inc 5.6Battery parameter · Lead-acid battery Parameter/Battery type Over-voltage cut-off voltage Equalization charging voltage Bulk charging voltage Float charging voltage Under-voltage alarm voltage Under-voltage cut-off voltage Discharging limit voltage Over-discharge delay time Equalization charging duration Equalization charging interval Bulk charging duration Sealed SLd 60V 58V 57.7V 55.2V 44V 42V 40V 5s 120m 30d 120m www.sungoldpower.com Gel GEL 60V 56.8V 56.8V 55.2V 44V 42V 40V 5s 120m Flooded FLd 60V 58V 57.6V 55.2V 44V 42V 40V 5s 120min 30d 120m User-defined USE 60V 40~60V settable 40~60V settable 40~60V settable 40~60V settable 40~60V settable 40~60V settable 1~30s settable 0~600min settable 0~250d settable 10~600m settable ! NOTICE Voltage Equalization charging voltage Bulk charging voltage Float charging voltage Battery full recharge point Current Float time Float Stage2 Constant voltage Stage3 Float Maintenance time All-in-one solar charge inverter V3.0 32 Sun Gold Power Inc · Li-ion batter Parameter/Battery type Ternary N13 N14 L16 Over-voltage cut-off voltage 60V 60V 60V Equalization charging voltage - - - Bulk charging voltage 53.2V 57.6V 56.8V Float charging voltage 53.2V 57.6V 56.8V Under-voltage alarm voltage 43.6V 46.8V 49.6V Under-voltage cut-off voltage 38.8V 42V 48.8V Discharging limit voltage 36.4V 39.2V 46.4V Over-discharge delay time 30s 30s 30s Equalization charging duration - - - Equalization charging interval Bulk charging duration - 120min settable - 120min settable - 120min settable LFP L15 60V 53.2V 53.2V 46.4V 45.6V 43.6V 30s - 120 m settable www.sungoldpower.com Userdefined L14 USE 60V 60V 49.2V 49.2V 43.2V 42V 40.8V 30s - 120 m settable 40~60V settable 40~60V settable 40~60V settable 40~60V settable 40~60V settable 40~60V settable 1~30s settable 0~600min settable 0~250d settable 10~600min settable All-in-one solar charge inverter V3.0 33 Sun Gold Power Inc 6. Communication 6.1Overview www.sungoldpower.com 1 USB-B port 2 3 RS485/CAN port 4 6.2USB-B port WIFI port Dry contact port USB2.0 printer cable The user can read and modify device parameters through this port by using the host software. Please contact us for the host software installation package if you require one All-in-one solar charge inverter V3.0 34 Sun Gold Power Inc 6.3WIFI port www.sungoldpower.com The WIFI port is used to connect to the Wi-Fi/GPRS data acquisition module, which allows the user to view the operating status and parameters of the inverter via the mobile phone APP. RJ45 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Definition 5V GND / / / / RS485-A RS485-B ! NOTICE The Wi-Fi/GPRS data acquisition module need to be purchased separately. User can scan the QR code to download the mobile APP. 6.4RS485/CAN port The RS485/CAN port is used to connect to the BMS of Liion battery. ! NOTICE If you need the inverter to communicate with the lithium battery BMS, please contact us for the communication protocol or to upgrade the inverter to the corresponding software program. If you use a normal RJ45 network cable, please check the pin assignment, pin 1 & pin 2 usually need to be cut off for normal use. All-in-one solar charge inverter V3.0 RJ45 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 5V GND / CANH CANL / RS485-A RS485-B 35 Sun Gold Power Inc 6.5Dry contact Dry contact port with 4 functions: 1. Remote switch on/off 2. Switching signal output 3. Battery temperature sampling 4. Generator remote start/ stop www.sungoldpower.com Switching signal output Remote on/off Temperature samplingreserved Generator remote on/off Function Description When pin 1 is connected with pin 2, the inverter will switched off the AC Remote switch on/off output. When pin1 is disconnected from pin2, the inverter outputs normally. When the voltage of battery reaches the under-voltagelimitvoltage Switching signal output parameter 15pin 3 to pin 1 voltage is 0V, When the battery charging/discharging normally pin 3 to pin 1 voltage is 5V. Temperature sampling Pin 1 & Pin 4 can be used for battery temperature sampling compensation. reserved When the voltage of battery reaches the under-voltagealarmvoltage (parameter 14) orvoltagepointofutilityswitchtobattery (parameter 04), pin 6 to Generator remote pin 5 normal open, pin 7 to pin 5 normal close. start/stop When the voltage of battery reaches the voltagepointofbatteryswitchtoutility (parameter 05) or battery is full. pin 6 to pin 5 normal close, pin 7 to pin 5 normal open. (Pin 5/6/7 outputs 125Vac/1A, 230Vac/1A,30Vdc/1A) ! NOTICE If you need to use the remote start/stop function of the generator with dry contact, ensure that the generator has ATS and supports remote start/stop. All-in-one solar charge inverter V3.0 36 Sun Gold Power Inc 7. FaultandRemedy 7.1Fault code Alarm Fault code www.sungoldpower.com Fault Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 Meaning BatVoltLow BatOverCurrSw BatOpen BatLowEod BatOverCurrHw BatOverVolt BusOverVoltHw BusOverVoltSw PvVoltHigh PvBoostOCSw PvBoostOCHw SpiCommErr OverloadBypass OverloadInverter AcOverCurrHw AuxDSpReqOffPWM InvShort Bussoftfailed OverTemperMppt OverTemperInv FanFail EEPROM Does it Affect the outputs Instructions Yes Battery under-voltage alarm Battery discharge over-current, software Yes protection Yes Battery disconnected alarm Battery under-voltage stop discharging Yes alarm Yes Battery over-current hardware protection Yes Battery over-voltage protection Yes Busbar over-voltage hardware protection Yes Busbar over-voltage software protection Yes PV input over-voltage protection Boost circuit over-current software NO protection Boost circuit over-current hardware NO protection Yes Master-slave chip SPI communication failure Yes Bypass overload protection Yes Inverter overload protection Inverter over-current hardware Yes protection Yes Slave chip request switch off failure Yes Inverter short-circuit protection Yes Busbar soft start failure MPPT heat sink over-temperature NO protection Inverter heat sink over-temperature Yes protection Yes Fan failure Yes Reservoir failure All-in-one solar charge inverter V3.0 37 Sun Gold Power Inc www.sungoldpower.com Fault Code 23 Meaning ModelNumErr Does it Affect the outputs Instructions Yes Wrong model 24 Busdiff Yes Busbar voltage imbalance 25 BusShort Yes Busbar short circuit 26 Rlyshort 28 LinePhaseErr Yes Inverter output back flow to bypass Yes Utility input phase fault 29 BusVoltLow Yes Busbar under-voltage protection 30 BatCapacityLow1 31 BatCapacityLow2 32 BatCapacityLowStop 58 BMSComErr 60 BMSUnderTem 61 BMSOverTem 62 BMSOverCur 63 BMSUnderVolt Battery SOC below 10% alarm (Only Yes enable BMS take effect) Battery SOC below 5% alarm (Only NO enable BMS take effect) Battery dead (Only enable BMS take Yes effect) NO BMS communication failure BMS under-temperature alarm (Only NO enable BMS take effect) BMS over-temperature alarm (Only NO enable BMS take effect) BMS over-current alarm (Only enable NO BMS take effect) BMS under-voltage alarm (Only enable NO BMS take effect) 7.2Troubleshooting Fault Code Meaning Causality Remedy / Screen no display No power input, or Closing the circuit breaker. Ensure the rocker switch is ON. Push any button on in sleep mode. the panel to exit sleep mode. The battery voltage is lower Charge the battery and wait until the 01 Battery under-voltage than the value set in battery voltage is higher than the value parameter [14]. set in the parameter item [14]. The battery is not Check whether the battery is reliably connected; check whether the circuit 03 Battery not connected connected, or the BMS in breaker of the battery is not closed; discharge protection ensure that the BMS of the Li-ion battery can communicate properly. All-in-one solar charge inverter V3.0 38 Sun Gold Power Inc www.sungoldpower.com Fault Code Meaning Causality Remedy 04 The battery voltage is Battery over-discharge lower than the value set in the parameter [12]. Manual reset: Power off and restart. Automatic reset: charge the battery so that the battery voltage is higher than the value set in the parameter item [35]. Manually power off and restart. 06 Battery over-voltage when charging Battery is in over-voltage condition. Check to see if the battery voltage exceeds the limit. If it exceeds, the battery needs to be discharged until the voltage is below the battery's over-voltage recovery point. 13 Bypass over-load (software detection) Bypass output power or output current overload for a certain period of time. Reduce the load power and restart the device. Please refer to item 11 of the Inverter Inverter output power or protection features for more details. 14 overload(software output current overload for detection) a certain period of time. Heat sink of PV input Heat sink of PV input 19 over-temperature (software detection temperature exceeds 90 for 3s. Resume normal charge and discharge when the temperature of the heat sink has 20 Heat sink of inversion over-temperature Heat sink of inversion temperature exceeds 90 cooled to below the over-temperature recovery temperature (software detection) for 3s. 21 Fan failure Fan failure detects by hardware for 3s. Manually toggle the fan after switching off to check for blockage by foreign objects. Manually power off and restart; if the fault 26 AC Input relay shortcircuit Relay for AC input sticking reappears after restarting,You need to contact the after-sales service to repair the machine. 28 Utility input phase fault AC input phase does not coincide with AC output phase Ensure that the phase of the AC input is the same as the phase of the AC output, e.g. if the output is in split-phase mode, the input must also be in split-phase. ! NOTICE If you encounter a fault with the product that cannot be solved by the methods in the table above, please contact our after-sales service for technical support and do not disassemble the equipment yourself. All-in-one solar charge inverter V3.0 39 Sun Gold Power Inc 8. ProtectionandMaintenance 8.1Protection features www.sungoldpower.com No Protection Feature Instruction When the charging current or power of the PV array configured PV input current/power 1 exceeds the PV input rated value, the inverter will limit the input limiting protection power and charge at the rated. If the PV voltage exceeds the maximum value allowed by the 2 PV input over-voltage hardware, the machine will report a fault and stop the PV boost to output a sinusoidal AC wave. At night, the battery is prevented from discharging through the PV night reverse 3 PV module because the battery voltage is greater than the current protection voltage of PV module. When the AC input voltage of each phase exceeds 140V, the AC input over-voltage 4 mains charging will be stopped and switched to the inverter protection mode. AC input under-voltage When the AC input voltage of each phase below 90V, the utility 5 protection charging will be stopped and switched to the inverter mode. When the battery voltage reaches the over-voltage cut-off point, Battery over-voltage 6 the PV and the utility will automatically stop charging to prevent protection the battery from being overcharged and damaged. When the battery voltage reaches the under-voltage cut-off Battery under-voltage 7 point, the inverter will automatically stop the battery discharge protection to prevent damage from over-discharging the battery. After a period when the battery current exceeds that allowed by Battery over-current 8 the hardware, the machine will switch off the output and stop protection discharging the battery. When a short-circuit fault occurs at the load output terminal, the AC output is immediately turned off and turned on after 1 AC output short-circuit second.If the output load terminal is still short-circuited after 3 9 protection attempts, the inverter must be manually restarted after first removing the short- circuit fault from the load before the normal output can be restored. When the internal temperature of the inverter is too high, the Heat sink over- inverter will stop charging and discharging; when the 10 temperature protection temperature returns to normal, the inverter will resume charging and discharging. Inverter over-load After triggering the overload protection the inverter will resume 11 protection output after 3 minutes, 5 consecutive overloads will switch off All-in-one solar charge inverter V3.0 40 Sun Gold Power Inc 12 AC output reverse Bypass over-current 13 protection Bypass phase 14 inconsistency protection www.sungoldpower.com the output until the inverter is restarted. (102%<load<110%) ±10%: error and output shutdown after 5min; (110% < load < 125%) ±10%: error and output shutdown after 10s. Load > 125% ±10%: error reported and output switched off after 5s. Prevents AC back flow from the battery inverter to the bypass AC input. Built-in AC input over-current protection circuit breaker. When the phase of the bypass input and the phase of the inverter split do not match, the inverter disables switching to the bypass output to prevent the load from dropping out or shortcircuiting when switching to the bypass. 8.2Maintenance To maintain optimum and long-lasting working performance, we recommend that the following items are checked twice a year. 1. Ensure that the airflow around the inverter is not blocked and remove any dirt or debris from the radiator. 2. Check that all exposed conductors are not damaged by sunlight, friction with other surrounding objects, dry rot, insect or rodent damage, etc. The conductors need to be repaired or replaced if necessary. 3. Verify that the indications and displays are consistent with the operation of the equipment, note any faults or incorrect displays and take corrective action if necessary. 4. Check all terminals for signs of corrosion, insulation damage, high temperatures or burning/discolouration and tighten terminal screws. 5. Check for dirt, nesting insects and corrosion, clean as requiredClean the insect screen regularly. 6. If the lightning arrester has failed, replace the failed arrester in time to prevent lightning damage to the inverter or other equipment of the user. · Make sure that the inverter is disconnected from all power sources and that the capacitors are fully discharged before carrying out any checks or operations to avoid the risk of electric shock. The Company shall not be liable for damage caused by : 1. Damage caused by improper use or use in a wrong location. 2. Photovoltaic modules with an open circuit voltage exceeding the maximum permissible voltage. 3. Damage caused by the operating temperature exceeding the restricted operating temperature range 4. Dismantling and repair of the inverter by unauthorised persons. 5. Damage caused by force majeure: damage during transport or handling of the inverter. All-in-one solar charge inverter V3.0 41 Sun Gold Power Inc 9. Datasheet www.sungoldpower.com MODEL SPH8K48SP SPH10K48SP CAN BE SET INVERTER OUTPUT Rated Output Power 8,000W 10,000W Max.Peak Power 16,000W 20,000W Rated Output Voltage 120/240Vacsplit phase/single phase Y Load Capacity of Motors 5HP 6HP Rated AC Frequency 50/60Hz Y Waveform Pure Sine Wave Switch Time 10mstypical Parallel capacity / After triggering the overload protection the inverter will resume output after 3 minutes, 5 consecutive overloads will switch off the output until the inverter is restarted. Overload (102%<load<110%) ±10%: error and output shutdown after 5min; (110% < load < 125%) ±10%: error and output shutdown after 10s. Load > 125% ±10%: error reported and output switched off after 5s. BATTERY Battery Type Li-ion / Lead-Acid / User Defined Y Rated Battery Voltage 48Vdc Voltage Range 40-60Vdc Y Max.MPPT Charging Current 200A Y Max.Mains/Generator Charging Current 100A 120A Y Max.Hybrid Charging Current 180A 200A Y PV INPUT Num. of MPP Trackers 2 Max.PV array power 11,000W Max.input current 22/22A Max.Voltage of Open Circuit 500Vdc MPPT Voltage Range 125-425Vdc MAINS / GENERATOR INPUT Input Voltage Range 90-140Vac Frequency Range 50/60Hz Bypass Overload Current 63A EFFICIENCY MPPT Tracking Efficiency Max. Battery Inverter Efficiency 99.9% 92% All-in-one solar charge inverter V3.0 42 Sun Gold Power Inc GENERAL Dimensions Weight Protection Degree Operating Temperature Range Noise Cooling Method Warranty COMMUNICATION Embedded Interfaces External Modules Optional CERTIFICATION Safety EMC RoHS 620*445*130mm2*1.5*0.4ft 24.5kg59lb IP20Indoor Only -10~55,>45 derated 14~131>113 derated <60dB Internal Fan 1 Years RS485 / CAN / USB / Dry contact Wi-Fi / GPRS www.sungoldpower.com Y Y IEC62109-1, IEC62109-2,UL1741 EN61000-6-1, EN61000-6-3, FCC 15 class B Yes All-in-one solar charge inverter V3.0 43