Automatic Air Separator 22mm – TFC Group – Tower


File Info : application/pdf, 8 Pages, 881.23KB

PDF preview unavailable. Download the PDF instead.

TFC-Airliminator-AIREL-Manual
.5
Airliminator
Installation & Operating Manual

Prior to installation, please read these installation and operating

instructions carefully. The product warranty requires the

installation and commissioning of Tower products to be carried

out by a qualified installer in compliance with BS 7593:2019 and

all local building regulations and accepted codes of practice in

force at the time of installation. Failure to follow the correct

WARNING installation or use of the product for any purpose outside of the manufacturers intended design will invalidate the product

warranty.

Boiler-m8®

Suite 11 Peel House, 30 The Downs,

www.boiler-m8.com sales@boiler-m8.com

11

Altrincham, Cheshire WA14 2PX

0333 305 8210

Contents
1. 25 Year Guarantee ................................................................ 2 2.Important Information .......................................................... 2 3.Component Parts.................................................................. 3 4.Installation Instructions ........................................................ 4 5.Annual Servicing Requirement .............................................. 5 6. Troubleshooting ................................................................... 6

Tower TFC Group

www.tfc-group.co.uk

Tower House, Vale Rise, Tonbridge

sales@tfc.uk.com

1

Kent TN9 1TB

01732 351 680

1. 25 Year Guarantee
Congratulations on your purchase of the Tower Airliminator. We want you to get the very best performance from it so this handbook includes information on safety, handling and care. Please retain this handbook in case you need to refer to any of this information in the future.
Your Airliminator comes with a market leading 25 year guarantee on the brass body (excludes seals), giving you ultimate piece of mind.
This guarantee specifically excludes losses caused by:
· Misuse or abuse · Modification or tampering · Lack of routine maintenance · Incorrect maintenance · Accidental damage · Failure to follow the installation instructions · Replaceable parts such as seals
2. Important Information
1. Installation should be carried out by a qualified professional. 2. Please check that all components are present. If there are any missing or
damaged parts, please contact your supplier immediately.

www.tfc-group.co.uk

Tower TFC Group

sales@tfc.uk.com

Tower House, Vale Rise, Tonbridge

01732 351 680

Kent TN9 1TB

2

3. Component Parts A B C
F

D

E

G

A Vent Cap D Stainless Steel Filter G Base Cap K N

B Vent Valve E Inlet H L R

C Float F Outlet I M

Tower TFC Group

www.tfc-group.co.uk

Tower House, Vale Rise, Tonbridge

sales@tfc.uk.com

3

Kent TN9 1TB

01732 351 680

4. Installation Instructions

Only a qualified heating engineer should install this product.
1 Locate a suitable section of your boiler's flow pipe for the airseparator to be installed, allowing for access and servicing. The Airliminator should always be installed on the flow from the boiler. If in doubt contact for further advice.

2 Isolate heating system and drain down.

3

Mark the pipe, using a suitable pencil or marker pen and cut out the marked section and remove burrs.

4 Fit the diverter onto the sections of cut pipe, ensuring the arrow direction on the part follows the heating system flow.
5 Tighten the compression nuts to ensure a watertight seal.

6 Fit the Airliminator body to the diverter by hand tightening the retaining ring (Do not over tighten). The Airliminator body must be installed vertically.
7 Refill the heating system ensuring that the correct amount of corrosion inhibitor is added.

8 Vent as required by using the Top Air Bleed Valve.

www.tfc-group.co.uk

Tower TFC Group

sales@tfc.uk.com

Tower House, Vale Rise, Tonbridge

01732 351 680

Kent TN9 1TB

4

5. Annual Servicing Requirement
To get the best out of your Airliminator, an annual check is recommended.
1. Remove vent cap, and test vent pin until system liquid passes. 2. If the system fluid is clear, and the magnetic system filter (if fitted) is serviced
and found to be satisfactory, no further servicing is required. 3. If however the system is heavily soiled, we recommend that it should be
drained to allow the Airliminator body to be removed from the system and checked for build-up of sludge/debris. 4. Once drained, unscrew the top section of the body to remove the float assembly and clean, taking care not to damage any components or seals. 5. Open the base cap to remove and check the stainless steel particulate filter.
6. Rinse down both of the removed pieces, ensuring any sludge/debris is disposed of correctly.
7. Check seals for damage and re-assemble 8. Re-attach the body to the diverter and refill the system in compliance with
BS7593:2019. 9. Vent the Airliminator once filled to check operation.

WARNING: Please observe the safety instructions provided in this document. This Care and attention should be taken at all times during installation and servicing.

Tower TFC Group

www.tfc-group.co.uk

Tower House, Vale Rise, Tonbridge

sales@tfc.uk.com

5

Kent TN9 1TB

01732 351 680

6. Troubleshooting
Problem 1: Water is leaking from the vent cap Solution: Turn off the system, isolate the Airliminator, and:
· Float arm and pin for debris · Check all seals. · Check the isolation valve nuts to ensure they are fully tightened. · Check the diverter retaining ring is firmly tightened and not cross threaded.
Problem 2: Poor flow through the Airliminator Solution: Clean the particulate filter when reduced flow is noted.