Owner's Manual for Caspian models including: CTFF60, CTFF120, CTFF60 Ceiling Mounted Heater, CTFF60, Ceiling Mounted Heater, Mounted Heater, Heater
File Info : application/pdf, 2 Pages, 133.82KB
DocumentDocumentCaspian® CTFF Education | Healthcare | Leisure and sport | Office | Hospitality | Retail | Showroom Caspian CTFF fits into 600mm x 600mm or 600mm x 1200mm ceiling tile, providing easy access for both installation and maintenance Caspian fan convectors are both a practical and high quality heating solution for any commercial project Incorporating the latest EC motor technology, which can result in running-cost savings as high as 70%, and with variable speed control as standard, the Caspian delivers heat quickly and quietly. It is possible to have master and slave Caspian fan convectors that integrate the entire range of EC Caspian products. Please contact either our sales team or technical team to ensure that this is correctly specified Caspians are compatible with most types of wet central heating systems, functioning equally efficiently with conventional boilers, biomass technology or ground or air source heat pumps EC versions are now available with Caspian Smart Controls, for more information please visit our website: https://smithsep.co.uk/catalogue/caspian-smart-controls/ Product Information Motor EC (BMS compliant). Finish Casing: zinc-coated steel 1.2mm. Polyester powdercoated: white RAL 9010. Available to special order in any colour. Filter Class G2, 100% polyester, non-washable. Installation Suitable for two-pipe central heating systems. Maximum installation height for high or ceiling mounting, - 4m to underside. Pipework access holes on the rear and underside. Key operated front access panels. Bleed valve accessible on removal of front casing. Unit must be earthed. Commissioning Check water is hot enough to activate the low temperature cut-out thermostat. Controls See accessories table. Specification To specify state: Fan Convector with EC motor (or AC), in 1.2mm zinc coated steel, 595mm x 595mm or 595mm x 1195mm. With variable heat output controller. As Smith's Caspian CTFF60/120 As part our commitment to continuous improvement Smith's Environmental Products may change the specifications of its products without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All dimensions are in mm unless otherwise stated. Please visit our website for the most up to date information. Issue 004 | January 2024 +44 (0) 1245 324 900 | sales@smithsep.co.uk | SmithsEP.co.uk Technical Data Heat output - EC Model Reference EC 60 EC 120 Fan Speed Low Mid High Low Mid High Control Voltage VDC 3.4 4.9 6.4 3.1 4.3 5.5 40°C MWT 0.85 1.02 1.18 1.62 2.31 2.99 45°C MWT 1.20 1.53 1.85 2.34 3.25 4.15 50°C MWT 1.45 1.92 2.38 3.32 4.27 5.21 55°C MWT 1.80 2.37 2.93 3.98 5.15 6.31 60°C MWT 2.16 2.76 3.36 4.71 6.07 7.42 65°C MWT 2.35 3.18 4.00 5.62 7.02 8.41 70°C MWT 2.73 3.58 4.43 6.32 7.91 9.50 75°C MWT 3.08 4.05 5.02 6.99 8.74 10.48 80°C MWT 3.40 4.38 5.36 7.61 9.60 11.59 Model Reference EC 60 EC 120 Fan Speed Low Mid High Low Mid High Air Volume (m3/h) 201.00 290.50 380.00 419.30 549.65 680.00 Air Volume (l/s) 55.90 80.75 105.60 116.50 152.68 188.89 Specific Fan Power w/ls 0.14 0.26 0.32 0.14 0.26 0.34 Power Consumption (W) 8.00 21.00 34.00 16.00 40.00 64.00 NR in typical room* 34.00 41.50 49.50 34.00 42.00 49.96 Hydraulic Resistance (KPA) 1.38 1.69 2.00 17.78 20.59 23.40 Nominal Weight (KG) 23.00 45.00 Water Capacity (L) 0.92 2.08 *a typical room is taken as a room with a volume of 173m3 and a reverberation time of 0.8 seconds at 500 Hz with one unit installed, situated against a wall or ceiling (radiating noise in a quartersphere). No allowance is made for attenuation provided by ceilings, enclosures or ductwork. Outputs based upon testing at EN442: 2014 using mean water temperature and an entering air temperature of 20°C with a 10°C temperature drop between flow and return. Correction factors Mean Water Temp °C Water Temperature drop °C Entering Air Temperature °C 15 18 20 25 45 - 80 5 10 15 20 1.13 1.10 1.07 1.05 1.08 1.05 1.02 0.99 1.04 1.00 0.95 0.89 0.93 0.91 0.89 0.86 Factors are approximate data based upon a standard coil. How to calculate Mean Water Temperature Mean water temperature (T) Flow temperature + Return temperature 2 Dimensions 245 A 595 65 270 242 110 Pipe Centres 45 Pipe Entry Model A 60 595 120 1195 80 80 Electrical supply in this side Ordering Guide Model Packed Wt (kg) CASPIAN CTFF60EC 23 CASPIAN CTFF60 C/W REMOTE SMART CONTROL 23 CASPIAN CTFF120EC 45 CASPIAN CTFF120 C/W REMOTE SMART CONTROL 45 Accessories FLEXIBLE HOSES 22MM PAIR ROOM THERMOSTAT HARD WIRED ROOM THERMOSTAT TAMPER PROOF CASPIAN PROPORTIONAL HEAT OUTPUT CONTROLLER 15°-25° REMOTE SENSOR (EC) CASPIAN PROPORTIONAL HEAT OUTPUT CONTROLLER 11°-21° REMOTE SENSOR (EC) BLANK CONFIGURABLE PROPORTIONAL HEAT OUTPUT CONTROLLER (PROGRAMMED AT FACTORY) CASPIAN ADJUSTABLE LOW TEMPERATURE CUT-OUT (EC AND AC) CASPIAN EXTERNAL CONTROL HARNESS (EC) CASPIAN EC LINKING KIT (MASTER/SLAVE) CASPIAN REMOTE SWITCHING ON/OFF RELAY (24V AC COIL) CASPIAN THERMOSTAT (T1) (EC & AC LOW LEVEL) Product Code HPCA29004 HPCA30005 HPCA29003 HPCA30004 HAGA95003 HAGA95001 HACA95004 HACA33037 HACA33118 HACA33126 HACA33001 HACA33004 HACA33068 HACA33127 HACA33002 As part our commitment to continuous improvement Smith's Environmental Products may change the specifications of its products without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All dimensions are in mm unless otherwise stated. Please visit our website for the most up to date information. Issue 004 | January 2024 +44 (0) 1245 324 900 | sales@smithsep.co.uk | SmithsEP.co.uk