Environment Meter Series
Particle Mass Concentration Detector
User Manual
Device Overview
This device is a Particle Mass Concentration Detector, capable of measuring PM2.5 and PM10 levels. The display shows current readings for PM2.5 (e.g., 26 µg/m³), PM10 (e.g., 65 µg/m³), temperature (e.g., 26.6°C), and humidity (e.g., 32.5%RH). Control buttons include SET, ENTER ([power button]), and MEM.
Important Note: Please read this manual before switching the unit on. Important safety information is included inside.
1-Description
This device is an air quality detector featuring intelligent induction and cloud data storage. It can detect PM2.5, PM10, CO2, HCHO, TVOC, temperature, and humidity. Utilizing a laser scattering weight test method with a professional structure design, fan, and particle sensor, it sensitively and precisely detects and monitors PM2.5 and PM10, helping users understand indoor air quality and take steps to improve it. A professional CO2 sensor provides reminders to open windows when CO2 concentration is too high. HCHO detection identifies formaldehyde, and TVOC detection identifies indoor harmful gases, aiding in understanding environmental pollution. The device employs a reliable power supply circuit to ensure precise and stable measurements and extended operating time when detecting multiple parameters simultaneously. An optional WiFi module enhances intelligence, enabling cloud data storage and remote viewing/control via a mobile phone. A noise detection module is equipped, allowing the device to be awakened from sleep mode by generating a slight noise.
2-Features
Feature | Model 1 | Model 2 | Model 3 |
---|---|---|---|
Measure Mass Concentration of PM2.5/PM10/HCHO | ✔️ | ✔️ | ✔️ |
Measure CO2 | ✔️ | ✔️ | ✔️ |
Measure HCHO | ✔️ | ✔️ | ✔️ |
Measure TVOC | ✔️ | ✔️ | ✔️ |
Measure Temperature & Humidity | ✔️ | ✔️ | ✔️ |
Wifi | Optional | Optional | Optional |
3''TFT LCD Display, 240*400 Pixels | ✔️ | ✔️ | ✔️ |
5000 groups of sampling data | ✔️ | ✔️ | ✔️ |
3-Specifications
Particle Measure
- Particle Channels: PM2.5/PM10
- Mass Concentration Range: 0~2000µg/m³
- Resolution: 1µg/m³
CO₂ Measure
- Range: 0~9999ppm
- Accuracy: ±5%±75ppm
- Resolution: 1ppm
HCHO
- Range: 0.00~5.00mg/m³
- Accuracy: ±5%F.S
- Resolution: 0.01mg/m³
TVOC Measure
- Range: 0.00~9.99mg/m³
- Accuracy: ±5%F.S
- Resolution: 0.01mg/m³
Temperature & Humidity Measure
- Temperature Range: -20~70°C (-4~158°F)
- Temperature Accuracy: ±2°C
- Temperature Resolution: 0.1°C
- Humidity Range: 0~100%RH
- Humidity Accuracy: ±3.5%RH (20~80%RH), ±5%RH (0~20%RH or 80~100%RH)
- Humidity Resolution: 0.1%RH
Intelligent Sensor
- Noise Detect Sensor: A slight noise can awaken device
WiFi
- Connection Properties: 802.11b, 802.11g, 802.11n (single stream) on channel 1-14@2.4GHz
- Maximum Bit Rate: 11Mbps@11b, 54Mbps@11g, 72Mbps@11n HT20
- Encrypt: WPA2
Power & Other Specifications
Power
- Battery: 2400mAh Recharge Li-ion Battery
- Work Time: Able to continue work almost 5 hours
- Charging: USB 5V/1A
- Charging Time: Almost 2 hours when shutdown
- Auto Sleep: Able to set auto sleep time
Others
- Display: 3"TFT LCD Display, 240*400 Pixels
- Data Storage: 5000 groups of sampling data
- Work Temperature: 0~50°C
- Storage Temperature: -10~60°C
- Size: 85*75*155mm
- Weight: 360g
4-Function
1-Machine Function & 2-Key Function
The device features multiple sensors and control keys. The front panel includes SET, Set/Up Key, ON/OFF/ENTER Key ([power button]), and Memory/Down Key. Sensors include CO2 Sensor and PM2.5 Sensor. The rear panel houses the WiFi Module, Noise Detect Sensor, USB port, and Temperature & Humidity Sensor.
The screen displays real-time measurements including PM2.5, PM10, temperature, and humidity.
Key Functions and Operation
Button Functions
- Set/Up Key: Long press to enter/exit the settings page; Short press to switch measurement display on the measure page, or to turn on/off in settings/memory page.
- ON/OFF/ENTER Key: Long press to startup/shutdown; Short press to enter/exit settings/memory page.
- Memory/Down Key: Long press to enter/exit the memory page; Short press to switch measurement display on the measure page, or to navigate down in settings/memory page.
5-Power ON/OFF
To power on, in shutdown mode, long press the ON/OFF/ENTER key until the screen lights up. To power off, in startup mode, long press the ON/OFF/ENTER key until the screen turns off.
6-Measure
After startup, the device continuously measures PM2.5, PM10, CO2, TVOC, HCHO, temperature, and humidity. The screen refreshes and cycles through displays of PM10, CO2, TVOC, and HCHO every 15 seconds. Users can manually switch the display by short-pressing the ON/OFF/ENTER key.
Warm-up Times: PM2.5, PM10, and CO2 require 3-5 seconds. TVOC requires 40 seconds. During warm-up, displayed data may be from the previous measurement. The device features six alarm levels indicated by color changes on the analog bar and measurement values. Alarms are based on real-time data. If WiFi is enabled, alarm information can be pushed to a mobile phone.
7-Shutdown, Sleep and Awaken
7-1. Shutdown/Sleep
The device can be set to auto power off or auto sleep to conserve power during periods of inactivity. Models 1/2/3 can be set for auto power off. Devices with WiFi can enter auto sleep mode, where the screen turns off but the device continues uploading measurement data.
7-2. Awaken by Key
Models 1/2/3 can be awakened from shutdown status by a long press of the ON/OFF/ENTER key. Devices with WiFi can be awakened from sleep status by a short press of any key.
7-3. Awaken by Noise
Noise can also awaken the device; for example, striking the table can transition the device from sleep status to measure status. Models 1/2/3 can awake by noise within 30 minutes after shutdown. Devices with WiFi can awake by noise when in sleep mode.
Measurement Progression Examples
The device screen dynamically displays readings. Examples of how measurements and air quality indicators change are shown:
- Initial state: PM2.5 at 26 µg/m³, PM10 at 65 µg/m³, 26.6°C, 32.5%RH.
- As air quality changes: PM2.5 may increase to 52 µg/m³ and TVOC to 0.96 mg/m³.
- Further changes: PM2.5 may rise to 107 µg/m³ and TVOC to 1.86 mg/m³.
- Continued deterioration: PM2.5 can reach 182 µg/m³ and HCHO 0.13 mg/m³.
- Further increases: PM2.5 may show 293 µg/m³ and HCHO 0.13 mg/m³.
- Severe conditions: PM2.5 can reach 468 µg/m³ and PM10 685 µg/m³.
These examples illustrate how readings and associated air quality indicators (like 'bad') change, often accompanied by color shifts on the device display.
8-Memory
The device can record up to 5000 groups of historical data, including PM2.5, PM10, and the recording time.
Accessing Memory
- To enter/exit the memory page, long press the MEM/Down key while on the measure page.
- In the memory page, short press the ON/OFF/ENTER key to view static measurement data curves.
- In the static memory page, use the Up/Down keys to navigate through historical data points one by one.
Memory Display
The memory page dynamically displays the latest measurement data curve. Each curve represents eight data points. A bright spot indicates a specific measurement data point, a dark spot signifies a connection (potentially indicating a gap or transition), and a dot represents the current data point. The graph typically shows PM2.5 and PM10 concentrations over time, with axes for concentration (µg/m³) and time.
9-Settings
Navigate the settings menu by long-pressing the SET/Up key from the measure page. Within settings, use Up/Down keys to select an item and ON/OFF/ENTER key to enter submenus or confirm selections. Short-press ON/OFF/ENTER to exit submenus and return to the main settings menu.
9-1. Time Settings
Users can configure the time settings, including 12-hour or 24-hour format, AM/PM, date (Year, Month, Day), and time (Hour, Minute). Short-press Up/Down to change values and ON/OFF/ENTER to confirm.
9-2. Measure Mode Settings (WiFi Model Enabled)
The device offers two measurement modes:
- Regular Measure: In this mode, the device will automatically power off after a period of inactivity.
- Monitor Measure: In this mode, the device enters auto sleep with the screen off but continues measuring and uploading data.
Regular Measure mode is the default setting.
9-3. Auto Power Off/Auto Sleep Settings
Configure auto power off or auto sleep timers, adjustable from 10 to 120 minutes, or disable these features entirely. WiFi-enabled devices can set specific auto power off times in regular measure mode or auto sleep times in monitor measure mode.
Settings (Continued)
9-4. Unit Settings
Select the desired unit for temperature measurement: Celsius (°C) or Fahrenheit (°F). Celsius is the default setting.
9-5. Alarm Settings
Configure the PM2.5 alarm threshold. Options include 10ppm, 35ppm, 75ppm, 150ppm, 200ppm, or no alarm. The default threshold is 35ppm. When the PM2.5 concentration exceeds the set point, the device will beep. WiFi-enabled devices can push alarm notifications to a mobile phone.
9-6. Brightness Settings
Adjust the screen brightness. There are 5 levels of brightness available.
9-7. Noise Sensor Settings
Enable or disable the noise sensor. When enabled, the device can be awakened from shutdown or sleep status by detecting noise.
9-8. Language Settings
Choose the display language for the device. Options include English and Chinese. English is the default language.
9-10. About Software
Access device information such as IMEI number, software version, and MAC address.
10-WiFi
10-1. First Connect
On first use, a flashing WiFi symbol appears in the top right corner of the measure page, indicating readiness to connect. Ensure your mobile phone is connected to WiFi. Use the mobile APP to input the current WiFi password and initiate broadcasting. The device will connect to WiFi after receiving the password, and the WiFi symbol will stop flashing. A steady WiFi symbol indicates successful connection to the server, with measure data being uploaded. The mobile phone can then access real-time and historical data, and control the device.
10-2. Has Connected WiFi
If the device has previously connected to WiFi, it will automatically reconnect upon startup without requiring manual intervention via the mobile phone. The mobile phone can remotely check the device's status (e.g., measuring, sleeping, or powered off).
10-3. Reconnect WiFi
If the WiFi password changes or a different WiFi network is to be used, reset the WiFi connection in the settings page and use the mobile phone's APP to reconnect. The reconnection process is the same as the first connection.
10-4. WiFi Function
Once connected to WiFi, the device can be linked to and remotely monitored by the mobile phone's APP. In monitor measuring mode, the device will not auto power off but will auto sleep, continuously uploading data to the server. The device can be awakened by the mobile phone's APP, a key press, or the noise sensor.
10-5. Product Service
- Maintenance or service not covered by this manual must be performed by qualified professionals.
- All replacement parts must be specified parts.
- Refer to the instrument for any changes in the operating manual; no prior notice will be given.
Attention & Safety Warnings
- Please do not use the device in environments with heavy dust to avoid particles entering the meter.
- To ensure accuracy, avoid using the device in heavy fog weather.
- Do not use the device in explosive environments.
- Always operate the device in accordance with this operating manual and do not attempt to disassemble the instrument.
11-Attached
11-1. Air Quality Standard
Chart 1.1 PM2.5 Concentration and Corresponding Index Color Table
Color | Green | Yellow | Orange | Red | Purple | Deep Purple |
---|---|---|---|---|---|---|
Concentration | 0~35 µg/m³ | 35~75 µg/m³ | 75~150 µg/m³ | 150~200 µg/m³ | 200~250 µg/m³ | >250 µg/m³ |
Air Quality | Good | Normal | Mild Polluted | Middle Polluted | Heavy Polluted | Serious Polluted |
Chart 1.2 PM10 Concentration and Corresponding Index Color Table
Color | Green | Yellow | Orange | Red | Purple | Deep Purple |
---|---|---|---|---|---|---|
Concentration | 0~75 µg/m³ | 75~150 µg/m³ | 150~300 µg/m³ | 300~400 µg/m³ | 400~500 µg/m³ | >500 µg/m³ |
Air Quality | Good | Normal | Mild Polluted | Middle Polluted | Heavy Polluted | Serious Polluted |
Chart 1.3 PM10, CO2, HCHO, TVOC Concentration and Corresponding Index Color Table
Parameter | Green | Orange | Red |
---|---|---|---|
CO₂ Concentration | 0~800ppm | 800~1500ppm | 1500~9999ppm |
HCHO Concentration | 0~0.05mg/m³ | 0.05~0.1mg/m³ | 0.1~5.00mg/m³ |
TVOC Concentration | 0~0.6mg/m³ | 0.6~1.8mg/m³ | 1.8~9.99mg/m³ |
Air Quality | Good | Normal | Bad |
CE [disposal symbol] Rev.170211