Owner's Manual for POTTER models including: NCE-1000 Ethernet Networking Card, NCE-1000, Ethernet Networking Card, Networking Card
Potter NCE-1000 Ethernet Networking Card - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 4 Pages, 1.70MB
DocumentDocumentFeatures · Allows for Peer-to-Peer networking via Ethernet (CAT5) · Up to 200 panels can be networked together · Any RA-6500 remote annunciator can be set as a global annunciator · NCE-1000 and NCF-1000 are interoperable and both types can be used within a network · Allows for a single panel to act as the host communicator · Five year warranty included NCE-1000 Ethernet Networking Card S2930 Description The NCE-1000 is used to network the fire alarm panels using CAT5 Ethernet cable. It is fully supervised and is capable of Class B and Class A operation. The NCE-1000 may be mounted in either the control panel cabinet, the PSN-1000/E, the AE-2, AE-8 or AE-14. When wiring Class A or B, the connection between the FACP and the module shall be limited to 20 feet and enclosed in conduit or equivalently protected against mechanical injury. Each card is mounted to the exclusive Stacker Bracket for secure and accessible mounting. A maximum of 31 NCE-1000s can be installed per panel, with a maximum of 200 panels per network. Technical Specifications Standby Current 50 mA Alarm Current 50 mA Operating 32° to 120°F (0° to 49° C) Temperature Range Operating Humidity 10%-93% (non-condensing) Range Operating Voltage 24 VDC Range Max no. of NCE- 31 1000 Dimensions (WxHxD) 4" x 6" x 1 5/8" Max Wire Length 300 ft for Ethernet Cable Wire Gauge P-Link 12 AWG - 18 AWG Compatible Panels IPA/AFC Series Addressable PFC-4064 Conventional Potter Electric Signal Company, LLC · St. Louis, MO · Phone: 800-325-3936 · www.pottersignal.com 8830162 - REV A · 10/20 PAGE 1 OF 4 firealarmresources.com Installation The NCE-1000 is connected to the fire control panels using a 4-wire RS-485 connection and Ethernet cable that connects to panel's P-Comm port.. The connection is power limited and supervised. The NCE-1000 can be mounted in either the control panel cabinet, intelligent power supply, the AE-2, AE-8 or AE-14. Each card is mounted to the exclusive Stacker Bracket for secure and accessible mounting. The connection between the FACP and the module shall be limited to 20 feet. Fig 1 NCE-1000 Ethernet Networking Card Potter Electric Signal Company, LLC · St. Louis, MO · Phone: 800-325-3936 · www.pottersignal.com 8830162 - REV A · 10/20 PAGE 2 OF 4 firealarmresources.com Class B Wiring FACP PANEL 1 P-COMM P-Link - +A B FACP PANEL 2 P-COMM P-Link - +A B FACP PANEL 3 P-COMM P-Link - +A B NCE-1000 Ethernet Networking Card NCE-1000 DIP SW S3 S1 = OFF S2 = OFF S3 = OFF S4 = OFF S3 - DIP SW S2 S1 = ON S2 = OFF S2 + Port 1 Port 2 Port 3 Port 4 A P-Link B Ground fault detection for cable segment ENABLED on Port 3 of Panel 1. Ground fault detection DISABLED on Port 3 of Panel 2. NCE-1000 DIP SW S3 S1 = ON S2 = ON S3 = OFF S4 = OFF - S3 DIP SW S2 S1 = OFF S2 = ON S2 + Port 1 Port 2 Port 3 Port 4 A P-Link B NCE-1000 DIP SW S3 S1 = OFF S2 = OFF S3 = OFF S4 = OFF - S3 DIP SW S2 S1 = OFF S2 = OFF S2 + Port 1 Port 2 Port 3 Port 4 A P-Link B Ground fault detection for cable segment ENABLED on Port 4 of Panel 2. Ground fault detection DISABLED on Port 3 of Panel 3. Potter Electric Signal Company, LLC · St. Louis, MO · Phone: 800-325-3936 · www.pottersignal.com 8830162 - REV A · 10/20 PAGE 3 OF 4 firealarmresources.com NCE-1000 Ethernet Networking Card Class A Wiring with Return FACP PANEL 1 P-COMM P-Link - +A B NCE-1000 DIP SW S3 S1 = OFF S2 = OFF S3 = ON S4 = OFF S3 - DIP SW S2 S1 = ON S2 = OFF S2 + Port 1 Port 2 Port 3 Port 4 A P-Link B FACP PANEL 2 P-COMM P-Link - +A B Ground fault detection for cable segment ENABLED on Port 3 of Panel 1. Ground fault detection DISABLED on Port 3 of Panel 2. NCE-1000 DIP SW S3 S1 = ON S2 = ON S3 = OFF S4 = OFF - S3 DIP SW S2 S1 = OFF S2 = ON S2 + Port 1 Port 2 Port 3 Port 4 A P-Link B Ground fault detection for cable segment ENABLED on Port 4 of Panel 3. Ground fault detection DISABLED on Port 4 of Panel 1. FACP PANEL 3 P-COMM P-Link - +A B Ground fault detection for cable segment ENABLED on Port 4 of Panel 2. Ground fault detection DISABLED on Port 3 of Panel 3. NCE-1000 DIP SW S3 S1 = OFF S2 = OFF S3 = ON S4 = OFF - S3 DIP SW S2 S1 = OFF S2 = ON S2 + Port 1 Port 2 Port 3 Port 4 A P-Link B Ordering Information Model Description NCE-1000 Network Card-Ethernet Stock No. 3992788 Note: For additional wiring diagrams and schematics, please reference the Potter 8830161 Peer to Peer Networking Guide. Potter Electric Signal Company, LLC · St. Louis, MO · Phone: 800-325-3936 · www.pottersignal.com 8830162 - REV A · 10/20 PAGE 4 OF 4 firealarmresources.com