Instruction Manual for DALC NET models including: DLM1248-1CV, DLM1224-1CV, DLM Single Channel MultiINPUT Device, DLM1248-1CV Variant DLM Single Channel MultiINPUT Device
DLM1248-1CV
LED lighting controllers, LED dimmers and RGB dimmers - Digimax
Pag. DLM single channel MultiINPUT Device Manual Made in Italy Rev. 2022-02-05 3 / 7 DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) – Italy
File Info : application/pdf, 7 Pages, 631.06KB
DocumentDocumentDLM single channel MultiINPUT Device Manual Made in Italy Rev. 2022-02-05 Pag.1 / 7 FEATURES · FADER+DIMMER+DRIVER · DC Input: 12-24-48 Vdc or 12-24 Vdc · MULTI INPUT Analogic Automatic Detection of the Local command: - Normally Open push-button - Analog input 0-10V - Analog input 1-10V - Potentiometer 10KOhm · PUSH MENU' Possibility to set: - Minimum value of dimming - Fade In - Fade Out · Constant Voltage variant for Common Anode applications · Voltage outputs for R-L-C loads, DLM1248-1CV variant · Voltage outputs for R loads, DLM1224-1CV variant · Memory function · Adjusting the brightness of white light or monochromatic colour · Adjusting the brightness up to completed off · Soft start and soft stop · Sync function - Master/Slave · Optimized output curve · Typical efficiency > 95% · 100% Functional test 5 Years warranty For the whole and updated Device Manual refer to producer's website: http://www.dalcnet.com CONSTANT VOLTAGE VARIANTS Application: Dimmer CODE DLM1248-1CV Input voltage 12-48V DC Output Channels 1 x 6,5A 1 DLM1224-1CV 12-24V DC 1 x 10A 1 The LED dimmer is produced by default with: - Analogic Automatic Detection of local command set as N.O. Push Button - Dimming minimum level 1% Analogic Auto Detection N° 1 N.O. Push Button N° 1 analog signal 0-10V N° 1 analog signal 1-10V N° 1 Potentiometer 10K N° 1 N.O. Push Button N° 1 analog signal 0-10V N° 1 analog signal 1-10V N° 1 Potentiometer 10K PROTECTIONS OTP Over temperature protection1 OVP Over voltage protection2 UVP Under voltage protection2 RVP Reverse polarity protection2 IFP Input fuse protection2 SCP Short circuit protection OCP Open circuit protection CLP Current limit protection DLM1248-1CV DLM1224-1CV 1 Thermal Protection on the output channel in case of high temperature. The thermal intervention is detected by transistor. 2 Only control Logic protection. DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy Headquarters: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy VAT: IT04023100235 Tel. +39 0444 1836680 - www.dalcnet.com info@dalcnet.com DLM single channel MultiINPUT Device Manual Made in Italy Rev. 2022-02-05 Pag.2 / 7 REFERENCE STANDARDS EN 61347-1 Lamp controlgear - Part 1: General and safety requirements EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment EN 61547 Equipment for general lighting purposes - EMC immunity requirements IEC 60929-E.2.1 Control interface for controllable ballasts - control by d.c. voltage - functional specification ANSI E 1.3 Entertainment Technology - Lighting Control Systems - 0 to 10V Analog Control Specification TECHNICAL SPECIFICATIONS DLM1248-1CV Variant Constant voltage Supply voltage min: 10,8 Vdc .. max: 52,8 Vdc Output voltage = Vin Input current Output current Absorbed nominal power3 @12V max 6,5A 6,5A 3 78 W @24V 156 W @48V 312 W Power loss in standby mode Type of Load Thermal shutdown4 <500mW R L C 150°C Command supply current 0,5mA (per 1-10V) Command required current (max) 0,1mA (per 0-10V) D-PWM dimming frequency 300Hz D-PWM resolution D-PWM range Storage Temperature 16 bit 0,1 100% min: -40 max: +60 °C Ambient Temperature Wiring Wire preparation length Protection grade min: -10 max: +40 °C 2.5mm2 solid 2.5mm2 stranded 30/12 AWG 5.5 6.5 mm IP20 Casing material Plastic Packaging unit (pieces/unit) Single Carton Box 1 pz Mechanical dimensions 44 x 57 x 25 mm Package dimensions 56 x 68 x 35 mm Weight 40g DLM1224-1CV Variant Constant voltage min: 10,8 Vdc .. max: 26,4 Vdc = Vin max 10A 10A 3 120 W 240 W - <500mW R - 0,5mA (per 1-10V) 0,1mA (per 0-10V) 300Hz 16 bit 0,1 100% min: -40 max: +60 °C min: -10 max: +40 °C 1.5mm2 solid 1mm2 stranded 30/16 AWG 5 6 mm IP20 Plastic Carton Box 10pz 44 x 57 x 19 mm 164 x 117x 70 mm 306g 3 Maximum value, dependent on the ventilation conditions. This value is measured at 40°C, it is maximum ambient temperature. 4 Thermal Protection on the output channel in case of high temperature. The thermal intervention is detected by transistor. DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy Headquarters: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy VAT: IT04023100235 Tel. +39 0444 1836680 - www.dalcnet.com info@dalcnet.com DLM single channel MultiINPUT Device Manual Made in Italy Rev. 2022-02-05 Pag.3 / 7 INSTALLATION To set the product, follow the instruction on the picture below: 1) connect the power supply (12-24 Vdc or 12-48 Vdc depending on the dimmer model) to terminal blocks "DC IN" of the device. 2) connect the LOCAL COMMAND to the terminal blocks "INPUT" of the device. 3) connect the LED in the output terminal blocks "OUT" of the device. DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy Headquarters: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy VAT: IT04023100235 Tel. +39 0444 1836680 - www.dalcnet.com info@dalcnet.com DLM single channel MultiINPUT Device Manual PUSH DIMMER FEATURE The intensity and the status change (ON/OFF) are controlled by the N.O. push button. Button Click Double Click Long pressure (>1s) from OFF Long pressure (>1s) from ON 15 Click in 5 second-time Intensity On/Off Maximum intensity Turn ON at 1% (Nightly Time), then dimmer up/down Dimmer up/down Enter in to PUSH MENU' Made in Italy Rev. 2022-02-05 Pag.4 / 7 0-10V & 1-10V & POTENTIOMETER FEATURE The intensity is controlled by input voltage variation. Button 0-10V 1-10V Potentiometer 10K Function Dimmer: 0-1V=0% Intensity 10V=100% PUSH MENU' FUNCTION AVAILABLE MINIMUM VALUE OF DIMMING POWER-ON RAMP (FADE IN) POWER-OFF RAMP (FADE OUT) ACCESS TO MENU' When you turn-on the LED dimmer, the output is set at 100% and the minimum of dimming is at 1 %. To access the device menu, click the push button 15 times in 5 seconds time. When the Load flashes, you are in "MENU' 1". · MENU' 1 MINIMUM VALUE OF DIMMING Every single click makes it changing the minimum value of dimming There are six level of minimum: 0,1%, 1%, 5%, 10%, 20%, 30% and 100% After setting the minimum value of dimming press long to confirm. A double flashing confirms the storage and you can go to "MENU' 2" Note: if you set the minimum level to 100%, once the settings is confirmed, the device automatically exits the MENU'. · MENU' 2 POWER-ON RAMP (FADE IN) Every single click makes it changing the power-on ramp There are five levels of power-on ramp (FADE IN): Instantaneous, 1 second, 2 seconds, 3 seconds, 6 seconds. After setting the FADE IN press a long to confirm. Three flashes confirm the storage and you can go to "MENU' 3" · MENU' 3 POWER-OFF RAMP (FADE OUT) Every single click makes it changing the power-off ramp There are five levels of power-off ramp (FADE OUT): Instantaneous, 1 second, 2 seconds, 3 seconds, 6 seconds. After setting the FADE OUT press long to confirm. Three quick flashes confirm the storage and you go out from the "DEVICE MENU'" When you are out of the Menu', the Lamp which is connected to the LED Dimmer turns on at the minimum level of dimming previously set. DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy Headquarters: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy VAT: IT04023100235 Tel. +39 0444 1836680 - www.dalcnet.com info@dalcnet.com LOCAL COMMAND DLM single channel MultiINPUT Device Manual Made in Italy Rev. 2022-02-05 Pag.5 / 7 AUTOMATIC DETECTION OF THE TYPE OF LOCAL COMMAND At the first switch the device is set by default to automatic recognition of push button N.O. Command. AUTOMATIC DETECTION OF THE 0/1-10V & POTENTIOMETER COMMAND The automatic recognition of analog signal 0/1-10V or potentiometer starts as a 0/1-10V value between 3V and 7V is sent out or setting the potentiometer with a value included from 30% and 70%. COMMAND 0-10V COMMAND 1-10V POTENTIOMETER AUTOMATIC DETECTION OF THE N.O. PUSH BUTTON COMMAND The N.O. push button s identified automatically after 5 clicks in rapid sequence. In mode N.O. push button, function memory is always active. PUSH BUTTON N.O. DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy Headquarters: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy VAT: IT04023100235 Tel. +39 0444 1836680 - www.dalcnet.com info@dalcnet.com DLM single channel MultiINPUT Device Manual Made in Italy Rev. 2022-02-05 Pag.6 / 7 SYNC INSTALLATION SYNC FUNCTION WITH SINGLE POWER SUPPLY It is possible to connect multiple device of the family DLM-1CV among them in mode Master/Slave Connect the local command desired to the device used as Master. Connect master "TX" signal to the "RX" entrances of slave. Example of Master/Slave: SYNC FUNCTION WITH ONE POWER SUPPLY FOR DIMMER In the case multiple power supplies are used to power "master" dimmer and "slave" dimmers, connect all the "COM" inputs of the LedDimmer to each other. NOTE FOR MASTER/SLAVE INSTALLATION 1) Using one power supply every single dimmer, first power on the Master unit and after that give power to the Slave. 2) When doing maintenance on the installation take care of shutting down power to the Slave units first and then to the Master. 3) When power to the Master unit is missing, the Slave set up automatically to the default ex-factory settings (power on 100%) or to the settings previously saved. DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy Headquarters: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy VAT: IT04023100235 Tel. +39 0444 1836680 - www.dalcnet.com info@dalcnet.com DLM single channel MultiINPUT Device Manual Made in Italy Rev. 2022-02-05 Pag.7 / 7 TECHNICAL NOTE Installation: · Installation and maintenance must be performed only by qualified personnel in compliance with current regulations. · The product must be installed inside an electrical panel protected against overvoltages. · The product must be installed in a vertical or horizontal position with the cover / label upwards or vertically; Other positions are not permitted. It is not permitted to bottom-up position (with the cover / label down). · Keep separated the circuits at 230V (LV) and the circuits not SELV from circuits to low voltage (SELV) and from any connection with this product. It is absolutely forbidden to connect, for any reason whatsoever, directly or indirectly, the 230V mains voltage to the bus or to other parts of the circuit. Power supply: · For the power supply use only a SELV power supplies with limited current, short circuit protection and the power must be dimensioned correctly. In case of using power supply with ground terminals, all points of the protective earth (PE = Protection Earth) must be connected to a valid and certified protection earth. · The connection cables between the power source "low voltage" and the product must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Use double insulated cables. · Dimension the power supply for the load connected to the device. If the power supply is oversized compared with the maximum absorbed current, insert a protection against over-current between the power supply and the device. Command: · The length of the connection cables between the local commands (N.O. Push button, 0-10V, 1-10V, Potentiometer or other) and the product must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Use double insulated shielded and twisted cables. · The length and type of the connection cables at the BUS SYNC must be less than 3m and they should be isolated from every wiring or parts at voltage not SELV. It is suggested to use double insulated shielded and twisted cables. · All the product and the control signal connect at the bus and at the local command (N.O. Push button, 0-10V, 1-10V, Potentiometer or other) must be SELV (the devices connected must be SELV or supply a SELV signal) Outputs: · The length of the connection cables between the product and the LED module must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Is preferable to use shielded and twisted cables. MECHANICAL DIMENSION DLM1224-1CV DLM1248-1CV | | | | | | | | | | | | | | DALCNET S.r.l, Registered office: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy Headquarters: Via Lago di Garda, 22 - 36077 Altavilla Vicentina (VI) Italy VAT: IT04023100235 Tel. +39 0444 1836680 - www.dalcnet.com info@dalcnet.com