User Manual for POSIFLEX models including: RT-6015-G2, RT-6016-G2, RT-6015Q-G2, RT-6016Q-G2, RT-6015-G2 Fanless Touch POS Terminal, Fanless Touch POS Terminal, Touch POS Terminal, POS Terminal, Terminal

UM RT-6xxx-G2 6xxxQ-G2 A0

PollyLin

[PDF] SOME IMPORTANT NOTESadpos.md › publicdownload

[PDF] SOME IMPORTANT NOTESadpos.adpos.ro › publicdownload


File Info : application/pdf, 20 Pages, 1.10MB

PDF preview unavailable. Download the PDF instead.

/home/adposro/adpos.md/image//pdf/UM RT-6xxx-G2 6xxxQ-G2 A0
RT-6015-G2/RT-6016-G2 RT-6015Q-G2/RT-6016Q-G2 Fanless Touch POS Terminal
User Manual
SOME IMPORTANT NOTES
FCC NOTES
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CE CLASS A WARNING
This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
AVERTISSEMENT CE CLASSE A
Cet équipement est conforme à la classe A de CISPR 32. Dans un environnement résidentiel, cet équipement peut provoquer des interférences radio.
WARRANTY LIMITS
Warranty will terminate automatically when the machine is opened by any person other than the authorized technicians. The user should consult his/her dealer for the problem happening. Warranty voids if the user does not follow the instructions in application of this merchandise. The manufacturer is by no means responsible for any damage or hazard caused by improper application.
LIMITES DE GARANTIE
La garantie prend fin automatiquement lorsque la machine est ouverte par une personne autre que les techniciens autorisés. L'utilisateur doit consulter son revendeur pour le problème qui se produit. La garantie s'annule si l'utilisateur ne suit pas les instructions d'application de cette marchandise. Le fabricant n'est en aucun cas responsable de tout dommage ou danger causé par une mauvaise application.
RT-6xxx-G2/6xxxQ-G2 Ver. A0
1

  SAFETY INSTRUCTIONS This equipment is not suitable for use in locations where children are likely to be present. CONSIGNES DE SÉCURITÉ Cet équipement ne convient pas à une utilisation dans des lieux pouvant accueillir des enfants.
WARNING Power cord shall be connected to a socket-outlet with earthing connection. ATTENTION Le cordon d'alimentation doit être connecté à une prise de courant avec mise à la terre. BATTERY WARNING Risk of explosion if battery is replaced by an incorrect type. Dispose of expended battery in accordance with local disposal regulations. AVERTISSEMENT DE BATTERIE Risque d'explosion si la batterie est remplacée par un type incorrect. Jetez la batterie usagée conformément aux réglementations locales en matière d'élimination.
 
Package Contents
 RT-6015-G2/RT-6015Q-G2 15" fanless touch terminal or RT-6016-G2/RT-6016Q-G2 15.6" fanless touch terminal................(x1)
 Power adapter....................................................................(x1)  Power cord......................................................................(x1)
2

Views of RT-6015-G2/RT-6016-G2
Front View
RT-6015-G2/ RT-6016-G2 P-Cap Touch Panel

15" RT-6015-G2 Rear View
Attachment Bay Stand Cover
Bottom View

15.6" RT-6016-G2 System Back Cover
Cable Exit

Screw for Fire-Resistant System Back Cover

Release Lever for System Back Cover 3

Left-Side View

Power Button Brightness Adjustment Button  Brightness Adjustment Button 

Views of RB-5000 UPS Base Stand (Option for RT-6xxx-G2 Model, NOT for RT-6xxxQ-G2 Model)

Top View

Bottom View

Rubber Foot

Battery Cable

Through Hole Screw Hole

BATT. DC OUT DC IN

When the AC power is turned off, the RT terminal will begin to be powered by the UPS battery and the RB-5000 will beep once every three seconds. At this time, back up the data on the terminal immediately and power off the RT terminal.

When the AC power is turned off, if the UPS battery is very low, the RB-5000 will beep once every second. At this moment, power off the RT terminal immediately.

To get more detailed information of RB-5000, please contact the service team of Posiflex or download the RB-5000 user manual from Posiflex Global Website: (https://download.posiflex.com/englobal/Download/index/manualUinstall_guide/pos-terminal/RT-6015-G2).
4

Views of RT-6015Q-G2/RT-6016Q-G2

Front View

Camera (Optional)

P-Cap Touch Panel

LED indicator 15" RT-6015Q-G2

LED indicator 15.6" RT-6016Q-G2

Rear View

Thumbscrew for VESA Mount Bracket

Attachment Bay

System Back Cover
Pole Mount Screw Hole

Bottom View

Screw Hole

Release Lever for System Back Cover 5

Right-Side View

Power Button Brightness Adjustment Button  Brightness Adjustment Button 

View of I/O Interface of RT-6xxx-G2/6xxxQ-G2 RT-6015-G2/RT-6016-G2
Bottom Side View

USB 3.0 Ports

DB9 COM Port

CR Port

LAN Port

RJ50 COM Ports

Mini DisplayPort

RT-6015Q-G2/RT-6016Q-G2 Bottom Side View

USB 2.0 Ports

DC IN Power Connector

DB9 COM Port

CR Port

USB 3.0 Ports LAN Port

RJ50 COM Ports

Mini DisplayPort

24V PoweredUSB Port

DC IN Power Connector

6

Left Side View
USB 2.0 Port
Positioning your POS for a Perfect Viewing Angle
Steady the base with one hand, and then tilt the screen in the direction shown by the arrow in the figure. Please do NOT press on the LCD panel while setting up the tilt angle.
Installing Power Adapter and Cables for RT-6xxx-G2
The following provides instructions required to install your cables. 1. Lay the terminal with its rear facing
towards you and tilt the screen all the way down.
7

2. Remove the system back cover. 2.1 If the system back cover is fire-resistant, first locate the screw as indicated in the figure, and then remove it.
Screw for Fire-Resistant System Back Cover
2.2 Hold down the release lever at the bottom of the system back cover and then pulling the cover outwards.

3. To remove the stand cover from the base, grab the top side of the

cover, (1) lift the stand cover up gently, (2) pull it at a 45 degree

angle, and then (3) slide it in the horizontal direction shown by the

arrow.

1

2

3
4. Connect the connector of the power adapter to the DC-IN power jack. If necessary, properly insert other cables into the correct port.

8

5. Neatly arrange the cables. Locate the cable holder inside the base as shown in the figure. Push down the lever to release if from the hook, pass the cable through cable holder, and then press down the lever again to lock it onto the hook.
Cable holder
6. Make sure the cord can be held into place and passed through the cable exit after sliding back the stand cover.
7. 7.1 Place back the sytem back cover. Make sure it is well locked into place with a click sound.
7.2 For the fire-resistant system back cover, please insert another screw into the screw hole indicated in the figure, and secure it.
Screw for Fire-Resistant System Back Cover
8. Make sure the cable could be pulled out of the cable exit from the bottom of the base.
9

Installing Power Adapter and Cables for RT-6xxxQ-G2
1. There are two thumbscrews on the VESA mount bracket. Loosen the two thumbscrews.
2. Open the VESA mount bracket, and make the bracket separate from the two metal sticks.
10

3. Connect the connector of the power adapter to the DC-IN power jack. If necessary, properly insert other cables into the correct port.
4. Close the VESA mount bracket, and then fasten the two thumbscrews.
Cable connectors like the connector of LAN cable have to be gently inserted until a click sound is given. It is recommended that the I/O ports, such as COM (DB9) port and VGA port, should be fastened with connector thumb screws after the I/O cable connectors are completely connected. And please make sure that each connector has to be connected to the right peripheral device in the right way. CAUTION: On doing insertion or extraction of a cable connector, please always hold the connector head itself instead of pulling the cable wire. Doing this could damage the cables, which is considered as an artificial damage and is not covered by the warranty. The means of power cord should be connected to a socket-outlet with earthing connection. ATTENTION: Lors de l'insertion ou de l'extraction d'un connecteur de câble, veuillez toujours tenir la tête du connecteur elle-même au lieu de tirer le fil du câble. Cela pourrait endommager les câbles, ce qui est considéré comme un dommage artificiel et n'est pas couvert par la garantie. Le cordon d'alimentation doit être connecté à une prise de courant avec mise à la terre.
Installing Optional Upgrade Kits and Peripherals
RT-6xxx-G2/6xxxQ-G2 is an expandable model which allows you to upgrade its own capacity by additionally installing multiple peripheral devices, such as magnetic stripe reader (MSR), fingerprint or iButton sensors, and 2nd rearmount POS monitor, according to your preference. The following will give you brief instructions on how to expand on your current POS system with these optional upgrade kits. Before proceeding with the installation of peripherals, please make sure the POS system is completely shut down to prevent damage.
11

 Installing Side Mount Upgrade Kits Located at left side on the back of your system unit, side mount compartment is mainly used for installation of side-mounted equipment, such as magnetic stripe reader. For detailed installation instructions, please refer to the user manual specific to the device which you intend to mount onto the terminal.
 Installing Rear-Mount POS Monitor RT-series POS terminal also allows you to additionally install rear-mount POS monitor to expand its functionality. Regarding the stepby-step instructions which aim to help you mount it onto your POS system, Please refer to the user manual specific to the device you intend to install.
 Installing PoweredUSB or USB Hub for RT-6xxx-G2
Please go through the below steps to complete the installation of PoweredUSB or USB hub. 1. After tilting the screen all the way down, remove the system back
cover. 1.1 If the system back cover is fire-resistant, first locate the screw as indicated in the figure, and then remove it.
Screw for Fire-Resistant System Back Cover
1.2 Hold down the release lever at the bottom of the system back cover and then pulling the cover outwards
12

2. To remove the stand cover from the base, grab the top side of the cover, (1) lift the stand cover up gently, (2) pull it at a 45 degree angle, and then (3) slide it in the horizontal direction shown by the arrow.

1

2

3
3. Align the two screw bolts at the bottom of PoweredUSB or USB hub with rail slots in the base.

4. Push PoweredUSB or USB hub in the direction shown by the arrow to lock it into place.
To remove the PoweredUSB or USB hub from the rail slots, press down the hubs first and then push it outwards.

13

5. Install power adaptor extension cable, USB cable, and power adaptor for PoweredUSB hub.
5.1 Insert one end of the provided power adaptor extension cable to DC Input port of PoweredUSB hub and another end to DC-in power jack of the terminal.
5.2 Insert mini-USB connector of the USB cable to PoweredUSB hub and another end to USB3.0 port of the terminal.
5.3 Connect the connector of the power adapter to DC Output port of PoweredUSB hub, and the other end to the electrical outlet.
6. To Install USB cable for USB hub, Plug Type-A connector of USB cable to USB Port of USB hub and the other end of USB cable to USB3.0 port of the POS terminal.
7. Neatly arrange your cable and then slide back the stand cover.
8. . 8.1 Place back the sytem back cover. Make sure it is well locked into place with a click sound
14

8.2 For the fire-resistant system back cover, please insert another screw into the screw hole indicated in the figure, and secure it.
Screw for Fire-Resistant System Back Cover

Status LED Indicator
LED status indicator, which is located at the bottom edge of the LCD panel, is mainly responsible for notifying users of the current system status by emitting various LED signals. In the chart provided below, it describes all the possible LED status as a quick reference.

15" 6015-G2/6015Q-G2 LED Status
Off Green Blue

Description System power OFF System standby System power ON

15.6" RT-6016-G2/6016Q-G2

LED Status

Description

Off

System power OFF

Orange

System standby

Blue

System power ON

Powering ON/OFF RT-6xxx-G2/6xxxQ-G2
Power ON RT-6xxx-G2/6xxxQ-G2 Press down the power button to power on the POS.

Power Button

Power OFF RT-6xxx-G2/6xxxQ-G2 In most cases, press the power button of the POS to power the system off. If the terminal fails to turn off the machine for unknown reasons, please be advised to hold the power button more than 10 seconds to force a shutdown of the system.

15

Installing an Operating System
You are highly advised not to install an operating system on RT-6xxxG2/6xxxQ-G2 without professional instructions. Improper installation could lead to system malfunction or failure. Please contact with your dealers about the issues of operating system installation.

Driver Download
If your POS terminal is shipped without OS pre-installed, please download the relevant driver that you need from the Posiflex website (https://download.posiflex.com/en-global/Download/index/driver/posterminal/RT-6015-G2).

Performing System Recovery
For RT-6xxx-G2/6xxxQ-G2 model with preloaded operating systems, Recovery DVD which includes useful utilities will be provided in the package to assist you in efficiently restoring or repairing your damaged system. However, you are not encouraged to recover your system without the help of system integrators. Please be advised to contact your service center for further assistance with system recovery.

Operation Environment

To prevent RT-6xxx-G2/6xxxQ-G2 from overheating, it is suggested to

position your terminal in a well-ventilated working environment. In doing so,

please be advised to keep the POS terminal at least 25mm away from other

devices to ensure the machine is properly cooled down and functioning

normally.
Specifications

RT-6015-G2

RT-6015Q-G2

RT-6016-G2

RT-6016Q-G2

CPU

Intel Tiger Lake Core i3 (default) /i5/i7 CPU

System Memory 2 x DDR4 SO-DIMM

Storage Device 2 x M.2 2280

OS Support

Windows 10 IoT

vPro

Supported by Intel Tiger Lake Core i5/i7 CPU

TPM

Yes, TPM2.0 (Intel PTT)

RAID

Yes

Power Supply

12V/60W,

12V/150W

can be upgraded to

150W while adopting

PoweredUSB module

in the base

16

LCD Panel
Touch Sensor Serial Port USB Port
PoweredUSB LAN Port Display Port
CR Port Audio Port Extension Slot Mechanical
Dimension (W x V x D in mm)
Environmental Requirements Regulation Rules Attachment RA-101 RA-103
RA-104 RA-301
LM/TM-4010 LM/TM-4011 LM/TM-4015 RT-460

15" 1024x768 TFT LCD with LED backlight

15.6" 1920x1080 TFT LCD with LED backlight

P-CAP touch

3 ports, DB9 x 1+ RJ-50 x 2

5 ports, USB3.0 x 2 + 3 ports, USB3.0 x 2 +

USB2.0 x 3 (2 on I/O USB2.0 x 1 (on left side)

plate, 1 on left side)

N/A

24V PoweredUSB x 1

10/100/1000 Mb x 1  eDP connector (internal header, support 15"

and 15.6" LCD panel)  VGA + USB + 12V (internal header,

supporting 2nd monitor)  1 x Mini DP port (on I/O plate)

1 port, controlling 2 CR

1 x Internal 2W speaker

1 x M.2 2230 slot for WiFi/BT module

With base stand

No base, intended for wall

mount/pole mount
RT-6015-G2: 368 x 325 x 207 RT-6015Q-G2: 368 x 292 x 46.6 RT-6016-G2: 402 x 297 x 207 RT-6016Q-G2: 402 x 251 x 41.2

Operating 0°C  40°C , 20%RH - 90%RH

Storage-20°C  70°C, 10%RH - 90%RH

FCC/CE

Slim MSR attachment for RT series iButton (or RFID) with one USB port attachment for RT series 2D scanner attachment for RT series 3-in-1 MSR + Fingerprint Sensor + 2D scanner attachment for RT series 9.7" 2nd display for RT series terminal 10.1" 2nd display for RT series terminal 15" 2nd display for RT series terminal PoweredUSB module to support 12Vand 24V Powered USB ports

17

(installed in base stand, NOT for RT-6xxxQ-G2)

RT-560 RB-5000

USB port replicator ( USB2.0 x 4, installed in base stand, NOT for RT-6xxxQ-G2)
UPS battery stand (NOT for RT-6xxxQ-G2)

Outline Dimension

RT-6015-G2

RT-6016-G2

18

RT-6015Q-G2
RT-6016Q-G2 19

 The product information and specifications are subject to change without prior notice. To get the detailed information on the RT-6xxx-G2/6xxxQ-G2, please check this model from Posiflex Global Website.
20



References

Microsoft Word 2016 Microsoft Word 2016