
Owner's Manual for TRIPP LITE models including: NGI-U08A Unmanaged Industrial Gigabit 10 100 1000 Ethernet Switch, NGI-U08A, Unmanaged Industrial Gigabit 10 100 1000 Ethernet Switch, 1000 Ethernet Switch, Ethernet Switch
TRIPP LITE NGI-U08A (01) PDF MANUAL - Manual-Hub.com
File Info : application/pdf, 20 Pages, 1,019.97KB
DocumentDocumentOwner's Manual
8-Port Unmanaged Industrial Gigabit 10/100/1000 Ethernet Switch with EIP QoS, DIN or
Wall-Mountable
Model: NGI-U08A
Este manual está disponible en español en la página de Tripp Lite: tripplite.com
Ce manuel est disponible en français sur le site Web de Tripp Lite : tripplite.com
- Tripp Lite : tripplite.com
Dieses Handbuch ist in deutscher Sprache auf der Tripp Lite-Website verfügbar: tripplite.com
WARRANTY REGISTRATION
Register your product today and be automatically entered to win an ISOBAR® surge protector in our monthly drawing!
tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA · tripplite.com/support Copyright © 2022 Tripp1Lite. All rights reserved.
https://manual-hub.com/
Package Contents
· NGI-U08A 10/100/1000 Ethernet Switch with EIP QoS · DIN Rail-Mounting Clip (Preinstalled) · Owner's Manual
Product Features
· 8 auto-negotiable 10/100/1000 Mbps RJ45 ports · Supports 10/100/1000Base-T, Full Duplex and auto MDI/MDI-X
crossover function · Simple plug-and-play installation and operation with no
configuration required · Rugged high-strength case · Industrial temperature switch models support operating
temperature range of -40°F to 167°F (-40°C to 75°C) · Easy-to-read LEDs indicate connection and activity status for
each port · Meets the following IEEE standards:
o IEEE 802.3 10Base-T o IEEE 802.3u 100Base-TX o IEEE 802.3 Auto Negotiation o IEEE 802.3x Flow Control o IEEE 802.1p Class of Service
2
https://manual-hub.com/
Product Features
· Supports MAC address auto-learning and auto-aging · EIP/QoS/Flow and Storm Control · Preinstalled durable rail clip mounts firmly to any standard
35 mm DIN rail
Optional Accessories
· N001-Series Cat5e 350 MHz Snagless UTP Cables · N002-Series Cat5e 350 MHz UTP Ethernet Cables · N200-Series Cat6 Gigabit Molded UTP Ethernet Cables · N201-Series Cat6 Gigabit Snagless Molded UTP Ethernet
Cables
3
https://manual-hub.com/
Product Overview
8-Port Unmanaged Industrial Gigabit 10/100/1000 Ethernet Switch with EIP QoS, DIN or Wall-Mountable
DIN Rail Grounding
Screw Power Input Terminal Block
DIP Switches
ALM RPS PWR
1000 Mbps
Top View Grounding Screw
LNK/ACT Front View
4
https://manual-hub.com/
DIN-Rail Mounting and Dismounting Instructions
ATTENTION: The NGI-U08A is an open-type device and shall be DIN-rail mounted or wall mounted (optional) in a cabinet or rack enclosure. The ambient temperature should not exceed 75°C
(167°F).
Mounting the Switch
Place the switch on the DIN rail from above using the built-in slot. Push the front of the switch toward the mounting surface until it snaps into place. You will hear a "click" to indicate it has successfully snapped into place.
Dismounting the Switch
Press the switch from the top, then pull out the lower edge of the switch to remove it from the DIN rail.
Push
Push
Click
Click
Mounting the Switch
Removing the Switch
5
https://manual-hub.com/
DIN-Rail Mounting and Dismounting Instructions
ATTENTION: A corrosion-free DIN mounting rail is advisable. When mounting the switch, be sure to allow enough space between devices to install the cabling and to ensure proper airflow.
Grounding the Switch
Grounding and wire routing help limit the effects of line noise caused by electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface, then connect the ground connection from the terminal block to the grounding surface prior to connecting devices. ATTENTION: This switch is intended for mounting on a wellgrounded surface, such as a metal panel.
6
https://manual-hub.com/
Wiring Requirements
WARNING: Safety measures should be taken before connecting the power cable. Turn off the power before connecting modules or wires. The correct power supply voltage is listed on the product label. Check the voltage of your power source to make sure you are using the correct voltage. DO NOT use a voltage greater than what is specified on the product label. Calculate the maximum possible current in each power wire and common wire. Confirm all electrical codes dictating the maximum current allowable for each wire size. If current exceeds the maximum rating, the wiring can overheat causing serious damage to your equipment. Please read and follow these guidelines: · Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point. Note: Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately. · You can use the type of signal transmitted through a wire to determine which wires should be kept separate. Wiring that shares similar electrical characteristics can be bundled together. · You should separate input wiring from output wiring. · Be advised that you should label the wiring to all devices in the system.
7
https://manual-hub.com/
Wiring Requirements Wiring Power Input
You can use "PWR" for Primary Power input and "RPS" for Redundant Power Input. Check the polarity while connecting. The top view of the Terminal Block is shown in the figure below:
PWR
RPS
ALM
Terminal Block CAUTION: · Use copper conductors only. · Wiring cable temperature should support at least 105°C
(221°F). · Tighten the wire to a torque value 0.5 N·m (4.5 in·lb). Note: The wire gauge for the terminal block should range between 12 and 24 AWG.
8
https://manual-hub.com/
Wiring Requirements
To insert power wire and connect the specified voltage and maximum electric current to the power terminal block, follow these steps: · Use a flat-head screwdriver to loosen the wire-clamp screws. · Insert the negative/positive DC wires into the PWR-/PWR+
terminals, respectively. · Tighten the wire-clamp screws to prevent the wires from
loosening. ATTENTION: Use a power supply from 12~48VDC, 0.5A maximum. The device power shall be supplied by LPS circuit.
9
https://manual-hub.com/
Wiring Requirements
Wiring the Relay Contact (ALM)
The switch has one set of relay alarm output. This relay contact uses two contacts of the terminal block on the switch top panel. The two contacts of the 6-pin terminal block connector are used to detect user-configured events. The two wires attached to the fault contacts form an open circuit when a user-configured event is triggered. If a user-configured event does not occur, the fault circuit remains closed.
PWR RPS ALM
Load
External Power
Relay rating: 24V, 1A
10
https://manual-hub.com/
Cabling
Connect one end of an RJ45 Ethernet cable (see Optional Accessories) into the switch's RJ45 Ethernet port. Connect the other end to a network device. Cat5e cable or above is recommended. · Ports 1-8 of the switch support Gigabit Ethernet (10/100/1000
Mbp speeds) · All ports support auto-negotiation and auto MDI/MDI-X to
eliminate the need for crossover cabling.
DIP Switch Settings
PWR RPS P1
ON OFF ON OFF ON OFF
Primary power alarm reporting is enabled Primary power alarm reporting is disabled Redundant power alarm reporting is enabled Redundant power alarm reporting is disabled Port 1 link alarm reporting is enabled Port 1 link alarm reporting is disabled
11
https://manual-hub.com/
Cabling
ON P2
OFF ON P3 OFF ON P4 OFF ON P5 OFF ON P6 OFF ON P7 OFF ON P8 OFF
Port 2 link alarm reporting is enabled Port 2 link alarm reporting is disabled Port 3 link alarm reporting is enabled Port 3 link alarm reporting is disabled Port 4 link alarm reporting is enabled Port 4 link alarm reporting is disabled Port 5 link alarm reporting is enabled Port 5 link alarm reporting is disabled Port 6 link alarm reporting is enabled Port 6 link alarm reporting is disabled Port 7 link alarm reporting is enabled Port 7 link alarm reporting is disabled Port 8 link alarm reporting is enabled Port 8 link alarm reporting is disabled
12
https://manual-hub.com/
LED Indicators
PWR (Green) RPS (Green)
Illuminated Off Illuminated Off
ALM (Red)
Illuminated
Off
1000 (Green) 1-8 RJ45 Ports
Illuminated Off
Illuminated LNK/ACT (Green)
1-8
Blinking
RJ45 Ports Off
Primary power on Primary power off or failure Redundant power on Redundant power off or failure Alarm triggered for abnormal power or port link down status Normal operation or DIP switch off Link speed at 1000 Mbps Link speed at 10/100 Mbps Port link up Activity (receiving or transmitting data) Port disconnected or link failed
13
https://manual-hub.com/
Specifications
Power Input Voltage Connection Reverse Polarity Protection Power Consumption (System Only) Grounding Screw Interface RJ45
LED
Alarm Relay Output
Dual-power inputs 12-48VDC/0.5A 6-pin terminal block Present
5W
Present
8 x 10/100/1000Base-T, auto-negotiation, auto-MDI/MDI-X, Full/Half Duplex and Flow Control PWR (Green): Power RPS (Green): Power by terminal block RPS ALM (Red): Power and RPS fails and RJ45 port link down 1000 (Green): Port 1~8 1000 Mbps Ethernet speed at 100 Mbps LNK/ACT (Green): Port 1~8 data transmitting/receiving 1 alarm relay output for power loss and port link down
14
https://manual-hub.com/
Specifications
Environmental Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude
-40°C to 75°C (-40°F to 167°F) -40°C to 85°C (-40°F to 185°F) 5 to 95% (Non-Condensing) 5 to 95% (Non-Condensing) 2000 m
Regulatory Approvals EMI/EMC
FCC Part 15 EN 55011 / BS EN 55011 EN 61000-6-4 / BS EN 61000-6-4 EN IEC 61000-6-2 / BS EN 61000-6-2 EN 55032 / BS EN 55032 EN 55024
ATTENTION: If the switch is used in a manner not specified here, the protection provided by the switch may be impaired.
15
https://manual-hub.com/
Warranty and Product Registration
3-Year Limited Warranty Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for a period of three (3) years from the date of initial purchase. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, at its sole discretion. THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction.) WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application.
Product Registration Visit tripplite.com/warranty today to register your new Tripp Lite product. You'll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product!* *No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
16
https://manual-hub.com/
Warranty and Product Registration
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic equipment from Tripp Lite, they are entitled to: · Send old equipment for recycling on a one-for-one, like-for-like basis
(this varies depending on the country) · Send the new equipment back for recycling when this ultimately
becomes waste
FCC Notice, Class B This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications to this equipment not expressly approved by Tripp Lite could void the user's authority to operate this equipment.
17
https://manual-hub.com/
Warranty and Product Registration
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos and illustrations may differ slightly from actual products.
18
https://manual-hub.com/
19
https://manual-hub.com/
1111 W. 35th Street, Chicago, IL 60609 USA · tripplite.com/support
20
22-10-200-9346C9_RevA
https://manual-hub.com/