Instruction Manual for PQL models including: 90408, 9040X LED Super Hybrid T8, 90408 9040X LED Super Hybrid T8

Installation Instruction

NovaLux 4-ft 18W LED T8 Tube, Hybrid, 2200 lm, 120V-270V, 5000K (NovaLux 90408) | HomElectrical.com


File Info : application/pdf, 6 Pages, 393.35KB

PDF preview unavailable. Download the PDF instead.

PQL-90408-Install 0
LED SUPER HYBRID T8·9040X
INSTALL INSTRUCTIONS
PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the instructions before you install and use the linear tube(s).
GENERAL: ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODE (N.E.C.) STANDARDS. IF YOU ARE UNFAMILIAR WITH PROPER ELECTRICAL WIRING CONNECTIONS OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN. REMOVE THE TRIM FROM THE BOX AND MAKE SURE THAT NO PARTS ARE MISSING. WARNING - Risk of fire or electric shock. LED linear tube installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING - Risk of fire or electric shock. Install these tubes only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING - Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors. THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. RETROFIT KIT INCLUDES; TUBE, OPERATION INSTRUCTION AND LABELS FOR SINGLE-ENDED OR DOUBLE-ENDED APPLICATION. SAFETY INFORMATION · Check the lamp before installation, if there is any damage caused during transportation, do not install. · Maintenance should be carried out by technical personnel only. · Do not stare and the light source with bare eyes or long periods of time, do not shine into others eyes. · Do not place objects on the lamp. · Keep lamp away from flames or high temperature objects. · Risk of electrical shock - Only replace with same type of LED tube. · If the glass lamp tube is broken, the lamp must be disposed of immediately. · Suitable for damp locations. · Not for use with dimmers. MAINTENANCE NOTES · Disconnect lamp from power supply before and maintenance. · Clean luminaire with dry cloth. · Do not clean the lamp with corrosive chemicals. OPERATIONAL MODES Mode I: Direct replacement, Plug & GoTM, compatible with most instant start electronic ballasts, see ballast compatibility list. Mode II: Direct wire, bypass, directly connects to the main: 120-277V · 50/60Hz, single or double ended.

L AC INPUT N

Single Ended (Use non-shunted sockets)

AC INPUT

L

N

Double Ended (Use shunted sockets)

!
WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

PREMIUM QUALITY LIGHTING®· www.PQLighting.com
© P.Q.L., Inc. · 2285 Ward Avenue · Simi Valley, CA 93065 · 800-323-8107

Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.

LED SUPER HYBRID T8·9040X
INSTALL INSTRUCTIONS
DIRECT REPLACEMENT (Plug & GoTM) INSTRUCTIONS · Mode I
SAFETY PRECAUTIONS · WARNING - Risk of Shock: Disconnect power before installation. · WARNING - Risk of Fire: Use only in place of fluorescent lamps specified on label. · LED T8 lamp for use only with products described and installed in accordance with product specifications. LED T8 lamp to be operated with qualified T8
fluorescent electronic ballast; check ballast compatibility list before installation. · This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical
navigation or communication equipment operating between 0.45-30MHz. · Do not install this lamp in a pre-heat luminaire. · This lamp only operates on electronic ballasts. If the lamp does not light when the luminaire us energized, remove lamp from luminaire and contact lamp
manufacturer or qualified electrician. · CAUTION - Risk of Fire: If the lamp or luminaire exhibits undesirable operation (buzzing, flickering, etc.) Immediately turn off power, remove lamp from
luminaire and contact manufacturer. · Suitable for damp locations. · Not for emergency lighting. · Not for use with dimmers. Suggestion for Direct Replacement Mode: Please use jumpered or shunted sockets, because this lamp can only be compatible with instant start electronic ballasts, and the bi-pin on lamp base are not electrically connected internally.
INSTALLATION 1. Make sure power is OFF. 2. Remove lens or diffuser (if applicable). 3. Remove existing fluorescent lamps from the luminaire. 4. Bring LED lamp to luminaire and insert lamp pins into luminaire lampholders. 5. Rotate LED lamp until lamp locks in place. Ensure that the LED lamp front points
away from the back of the luminaire. 6. Note: Install one LED T8 replacement lamp for each fluorescent lamp removed. 7. Place lens or diffuser back in place (if applicable). 8. Power On.

INSTANT START BALLAST WIRING DIAGRAM

· TWO LAMP BALLAST WIRING · CORRECT

WHITE

BLUE

BLACK

BALLAST

BLUE

RED

WHITE

BLUE

BLACK

BALLAST

BLUE

RED

LINE

LAMP

CAP

· TWO LAMP BALLAST WIRING · INCORRECT

WHITE

BLUE

BLACK

BALLAST

BLUE

RED

LINE

LAMP

LAMP

WHITE

RED

BLACK

BALLAST

BLUE

BLUE

LINE

LAMP

PREMIUM QUALITY LIGHTING®· www.PQLighting.com
© P.Q.L., Inc. · 2285 Ward Avenue · Simi Valley, CA 93065 · 800-323-8107

LINE

LAMP

CAP

Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.

LED SUPER HYBRID T8·9040X
INSTALL INSTRUCTIONS

DIRECT REPLACEMENT (Plug & GoTM) INSTRUCTIONS · Mode I

INSTANT START BALLAST WIRING DIAGRAM

· THREE LAMP BALLAST WIRING · CORRECT

WHITE BLACK

BLUE

BLUE

BALLAST

BLUE

RED

WHITE

BLUE BLUE

BLACK

BALLAST

BLUE

RED

LINE

LAMP

LAMP

CAP

· THREE LAMP BALLAST WIRING · INCORRECT

WHITE BLACK

RED

BLUE

BALLAST

BLUE

BLUE

LINE

LAMP

LAMP

LAMP

WHITE

BLUE BLUE

BLACK

BALLAST

BLUE

RED

LINE
WHITE BLACK

LAMP
CAP CAP

BLUE

BLUE

BALLAST

BLUE

RED

LINE

LAMP

WHITE

BLUE BLUE

BLACK

BALLAST

BLUE

RED

LINE

LAMP

CAP

LINE

LAMP

LAMP

DIRECT WIRE (Bypass) INSTRUCTIONS · Mode II

! WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

SAFETY PRECAUTIONS · Product should be installed by a qualified electrician · Switch off power supply before commencing work, make sure correct connection before powering back on. · This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation. · Suitable for damp locations. · Suitable for use with 5W Emergency Battery Backup - #90405 (Sold Separately). · Not for use with dimmers. · The units covered by this report were intended to retrofit surface mount, Type IC or non-IC recessed mount listed fluorescent luminaires that use
maximum 4 straight tubular lamps, the minimum lamp compartment dimensions are below:

MINIMUM COMPARTMENT OF LUMINAIRE 47.8" L x 23.8" W x 3" H

LAMP QUANTITY 4

CAUTION: "This luminaire has been modified to operate LED lamps. Do not attempt to install or operate fluorescent lamps in this luminaire," shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including re-lamping.

PREMIUM QUALITY LIGHTING®· www.PQLighting.com
© P.Q.L., Inc. · 2285 Ward Avenue · Simi Valley, CA 93065 · 800-323-8107

Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.

LED SUPER HYBRID T8·9040X
INSTALL INSTRUCTIONS

DIRECT WIRE (Bypass) INSTRUCTIONS · Mode II

! WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

SINGLE ENDED - The below ballast wiring represents typical configuration. The actual ballast wiring varies according to the ballast model. The socket should be non-shunted.

RETROFIT LUMINAIRE WITH ONE LAMP

INSTANT START

Electronic Ballast
Fluorescent Lamp

PROGRAM START OR RAPID START
INSTANT START
PROGRAM START OR RAPID START

Electronic Ballast
Fluorescent Lamp
RETROFIT LUMINAIRE WITH TWO LAMPS
Electronic Ballast
Fluorescent Lamp Fluorescent Lamp
Electronic Ballast
Fluorescent Lamp Fluorescent Lamp

LED Lamp
LED Lamp LED Lamp

RETROFIT LUMINAIRE WITH THREE LAMPS

INSTANT START

Electronic Ballast
Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp

PROGRAM START OR RAPID START

Electronic Ballast
Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp

PREMIUM QUALITY LIGHTING®· www.PQLighting.com
© P.Q.L., Inc. · 2285 Ward Avenue · Simi Valley, CA 93065 · 800-323-8107

LED Lamp LED Lamp LED Lamp
Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.

LED SUPER HYBRID T8·9040X
INSTALL INSTRUCTIONS

SINGLE ENDED WIRING INSTRUCTIONS

! WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING. RETROFIT LUMINAIRE WITH FOUR LAMPS

INSTANT START
PROGRAM START OR RAPID START

Electronic Ballast
Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp
Electronic Ballast
Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp

LED Lamp LED Lamp LED Lamp LED Lamp

DIRECT WIRE (Bypass) INSTRUCTIONS · Mode II DOUBLE ENDED - The below ballast wiring represents typical configuration. The actual ballast wiring varies according to the ballast model. It is not a
requirement to change the sockets (if in good condition) to operate double ended tubes, regardless of the socket type but, shunted or jumped sockets will provide the best connection. Please make sure one side of the fixture is connected to Live (L) and the other side to Neutral (N).
RETROFIT LUMINAIRE WITH ONE LAMP

INSTANT START

Electronic Ballast
Fluorescent Lamp

LED Lamp

PROGRAM START OR RAPID START
INSTANT START

Electronic Ballast
Fluorescent Lamp
RETROFIT LUMINAIRE WITH TWO LAMPS
Electronic Ballast
Fluorescent Lamp Fluorescent Lamp

LED Lamp
LED Lamp LED Lamp

PREMIUM QUALITY LIGHTING®· www.PQLighting.com
© P.Q.L., Inc. · 2285 Ward Avenue · Simi Valley, CA 93065 · 800-323-8107

Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.

LED SUPER HYBRID T8·9040X
INSTALL INSTRUCTIONS

DOUBLE ENDED WIRING INSTRUCTIONS

! WARNING - Disconnect power or circuit breaker before installing or servicing.

RETROFIT LUMINAIRE WITH TWO LAMPS (cont'd)

PROGRAM START OR RAPID START

Electronic Ballast
Fluorescent Lamp Fluorescent Lamp

LED Lamp LED Lamp

RETROFIT LUMINAIRE WITH THREE LAMPS

INSTANT START
PROGRAM START OR RAPID START

Electronic Ballast

Electronic Ballast

Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp

Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp
RETROFIT LUMINAIRE WITH FOUR LAMPS

LED Lamp LED Lamp LED Lamp
LED Lamp LED Lamp LED Lamp

INSTANT START

Electronic Ballast
Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp

LED Lamp LED Lamp LED Lamp LED Lamp

PROGRAM START OR RAPID START

Electronic Ballast
Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp Fluorescent Lamp

PREMIUM QUALITY LIGHTING®· www.PQLighting.com
© P.Q.L., Inc. · 2285 Ward Avenue · Simi Valley, CA 93065 · 800-323-8107

LED Lamp LED Lamp LED Lamp LED Lamp
Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.



References

PDFium PDFium