User Guide for fluidion models including: V1.5, V1.6.40, V1.6.41, V1.6.44, V1.6.45, ALERT One Handheld Microbiology Analyzer, ALERT One, Handheld Microbiology Analyzer, Microbiology Analyzer, Analyzer
Feb 11, 2025 — Download data Send datasets to serial port (use app to process). Set Threshold1 Adjust the risk thresholds. Date and Time Change device date and time.
ALERT One Handheld Microbiology Analyzer 22 www.fluidion.com Prepare vial and reagent Prepare sample and reagent (p.2) Mix thoroughly 1 Insert vial in the device Remove analyzer cap
File Info : application/pdf, 4 Pages, 486.03KB
DocumentDocumentALERT One Handheld Microbiology Analyzer V1.5 Need help ? Email support@fluidion.com www.fluidion.com 1 Quick Start Guide ALERT One Handheld Microbiology Analyzer Prepare vial and reagent 1 Prepare sample and reagent (p.2) Mix thoroughly Insert vial in the device 2 Remove analyzer cap Insert vial fully Replace analyzer cap 3 Power the analyzer Requirements: USB-C 5V DC, 15W Use supplied adapter or battery pack Battery must have trickle charge capability activated 4 Start the measurement Navigate to Measure menu Follow instructions below Menu Navigation Press Press & Hold (1s) Press & Long Hold (5s) Starting a Measurement X Scroll Up Scroll Down Cancel / Back OK / Validate Advanced Data Display* * While performing a measurement, or in the History menu Wait (2-14h) for measurement to end. Do not tilt ! E. Coli concentration per 100mL and corresponding risk level* Adjust water sample tem per atur e .. ... . - - - - - __ __ __ __ ___ ___ ___ ___ *Note: Risk thresholds are custom defined in the Settings Menu 22 www.fluidion.com Exploring Data History ALERT One Handheld Microbiology Analyzer Na vigate between mea sur emen ts using and Settings Menu Volume(ml): 50 Download data Send datasets to serial port (use app to process) Set Threshold1 Adjust the risk thresholds Date and Time Change device date and time Device Info Display serial number and firmware versions Clear Memory2 Delete all measurements from device memory Sound Toggle sound alerts On or Off Display T.C. Calib1 Volume (ml)1 Toggle display of Coliform results On or Off Select a specific calibration Set the water sample volume 1 Will affect future measurements 2 Will result in data loss Advanced Data Display: Long Press (5s) during measurement or in History Menu Fluorescence curve (E. coli signal) Absorbance curve (Coliform signal) Raw signals and algorithm version Available calibrations for use with ALERT One* · Not all may be present. New calibrations under constant development. 1.6.40 E.coli TC River - Plastic v2 (EV2024) Inquire with Fluidion for available upgrades. For freshwater (river, lake) 1.6.41 E.coli TC Seawater- Plastic v2 (EV2024) For seawater (ocean, brackish) 1.6.44 Enterococci River - Plastic (ENTRP-ALM2024) For freshwater (river, lake) 1.6.45 Enterococci Sea - Plastic (ENTSP-ALM2024) For seawater (ocean, brackish) www.fluidion.com 33 ALERT One Handheld Microbiology Analyzer Sample and Reagent Preparation* *Shown for single-use plastic vial. Glass vials currently not supported. Does not apply to Enterococci freshwater measurements inquire with Fluidion for protocol details Freshwater samples Seawater samples Add Add 50mL of bioreagent freshwater sample (to molded line) Add bioreagent Add 27mL of Add 9mL of sterile water seawater sample (to first line) (to second line) Sample and vial disposal procedure Dispose used vial as biological waste according to local regulations. If available, use appropriate biological waste collection services. Only when no biological waste collection service available, follow the vial disinfection procedure below: Add 1ml of concentrated liquid bleach to vial containing sample. Close, shake, wait 15 minutes. Pour content in sanitary drain. Dispose of singleuse plastic vials as trash, or, if available, recycle as polypropylene (PP) Important Safety Information: · Read the reagent Material's Safety Data Sheet (MSDS) before use. · Wear protective gloves when dealing with potentially contaminated samples. · Protect clothing from bleach projections to avoid staining. · Keep instrument and battery dry and protected from the elements · Ensure that reagent is within its validity period. · Do not leave device in direct sunlight. Max. ambient temperature: 37oC. · Do not tilt the device while performing a measurement. Alarm will sound. Product Warning The reagents used with this product cause rapid multiplication of E.coli and other potentially harmful biological substances. Used samples and reagents should never be disposed directly into the environment or drinking water sources. This product and all associated reagents and consumables should never be used or accessed by unsupervised children. 4 www.fluidion.com