
User Manual for WL4 models including: KPFRW-2TM Stand Alone Wifi Touch Keypad, KPFRW-2TM, Stand Alone Wifi Touch Keypad, Alone Wifi Touch Keypad, Wifi Touch Keypad, Touch Keypad, Keypad
Een WL4 KPFRW-2TM stand alone WiFi touch keypad, vingerafdruk en Mifare kaartlezer werkt met Tuya app geschikt voor buiten koop je bij WebStore4 met gratis bezorging in NL, BE en DE
Keypad Fingerprint Access Control User Manual Please read and understand this instruction completely before installation or operation - 1 - 1. Introduction This series'product is a new generation of multi-function standalone access control. It adopts new ARM core 32-bit microprocessor design, which is powerful, stable and reliable. It contains reader mode and standalone access control mode etc.. It's widely applied to different occasions, such as office, residential communities, villa, bank and prison etc.. 2. Features Read 125KHz EM Card and HID Card (Optional) Read 13.56MHz Mifare card and CPU card (Optional) Metal backlight keypad Contain reader mode, the transmission format could be adjusted by user. Support seven access ways Support admin add card and admin delete card 10,000 card/pin users and 600 fingerprint users. 3. Technical Specifications Operating Voltage: DC 12-24V Standby Current: 35mA Operating Current: 100mA Operating Temperature: -40~60 Operating Humidity: 0%~95% Access ways: Fingerprint, card, code, or multiple combination methods 4. Installation Remove the back cover from the keypad using the supplied special screw driver Drill 2 holes on the wall for the self-tapping screws and I hole for the cable Put the supplied rubber bungs to into the two holes Fix the back cover firmly on the wall with 2 self tapping screws Thread the cable through the cable hole Attach the keypad to the back cover. (See the figure below) - 2 - 5. Wiring No. Color 1 Green 2 White 3 Grey 4 Yellow 5 Brown 6 Red 7 Black 8 Blue 9 Purple 10 Orange Marks D0 D1 ALARM OPEN/ BEEP D_IN/ LED +12V GND NO COM NC Description Wiegand input (Wiegand output as reader mode) Wiegand input (Wiegand output as reader mode) Alarm signal MOS tube drain output end (optional) Exit button input end (Beeper input as reader mode) Door contact switch input (LED input as reader mode) (optional) Positive power supply or AC power supply end Negative power supply Relay NO end Relay COM end Relay NC end 6. Diagram 6.1 Common Power Supply Note: The door contact and alarm function are optional - 3 - 6.2 Special Power Supply Note: The door contact and alarm function are optional 6.3 Reader Mode - 4 - 7. Sound and Light Indication Operation Status Stand by Operation successful Operation failed Admin card enter programming Admin card exit programming Press digital key Press * key Press access code Read card under card plus code mode Read multi user cards Enter programming mode Enter setting status Unlocking Buzzer alarm Light indicator Red Green Red indicator flash slowly Red indicator flash slowly Red indicator flash slowly Red indicator flash slowly Orange Green Red indicator flash quickly Buzzer Beep-- Beep-Beep-Beep Beep-Beep Beep-- Beep Beep-- Alarm 8. Admin Menu 8.1 Standalone Mode Settings Device Management Enter programming Menu 00 01 Press * Admin code # 02 (Default admin code is "999999") 03 08 09 Operation steps Description Default value New admin code # new Change admin code admin code # 999999 Read card Set admin add card or admin / Input a fingerprint twice * add fingerprint Read card Set admin delete card or admin / Input a fingerprint twice * delete fingerprint 0# Reader mode 1# Standalone access control 1 mode 2# Relay toggle mode WIFI matching Optional Unlocking code # (4-6 digits) Public code - 5 - Add and Delete Users Enter Menu Operation steps programming 11 Press * Admin code # (Default admin 12 code is "999999") 13 Read card / Input a fingerprint twice... * Press 8 or 10 digits card number # ... * Press ID number # read card / Input a fingerprint twice ... * Press ID number # press 8 or 10 digits card number # ... * Press ID number # press code # ... * Read user card, input the first fingerprint twice, input the second fingerprint twice...* Press ID number # press 8 or 10 digits card number # input card quantity # Delete users Read card / Input a fingerprint once ... * 21 Press 8 or 10 digits card number #... * Press ID number # ... * 20 0000# Description Add card users or fingerprint users continuously Add card users by card number Add card users or fingerprint users by specific ID number Add card users by specific ID number and card number Add an independent user code by specific ID number Match fingerprints to a card (Maximum 2 fingerprints) Add conductive number card Delete card users by reading card / Delete fingerprint users by inputting fingerprint Delete card users by card number Delete users by ID number Delete ALL users Default value "..." means repeating the previous operation, Press * key to exit. "..." means repeating the previous operation, Press * key to exit. - 6 - Access Ways Enter programming Menu Press * Admin code # 31 (Default admin code is "999999") 32 Operation steps 0# 1# 2# 3# 4# 5# 6# 7# 1# 2-10 # Description Default value Forbidden opening door Entry by code only Entry by card only Entry by card+ code/fingerprint + code 4 Entry by card, fingerprint or code Entry by fingerprint only Entry by fingerprint + card Entry by multi-fingerprint / multi-card Set door open by 1 user card/user fingerprint 1 Set door open by 2-10 user cards/user fingerprints Advanced Settings Enter programming Menu 41 42 Operation steps (0-300) # 0 # (1-99) # 0# Press * Admin code # 61 (Default admin code is "999999") 62 63 64 1# 2# 0# 1# 0# 1# (2-99) # 0# 1# Description Default value Door opening time range: 0-300S 0 equals to 50mS 5 Alarming time sets 0S, means no alarm 0 Alarming time range: 1-99 min Normal working mode The external alarm and built-in buzzer will work if wrong operations are over 5 times. 0 The device will be locked out for 10 min if wrong operations are over 5 times. Disable light indicator 1 Enable light indicator Disable the keypad backlight Enable the keypad backlight 1 Time of keypad backlight: 2-99 sec Disable buzzer 1 Enable buzzer - 7 - 8.2 Reader Mode Settings Enter programming Menu 00 01 02 Press * Admin code # (Default admin code is 03 "999999") 11 21 20 42 51 52 Press * Admin code # (Default admin code is 53 "999999") 62 Operation steps Description Default value New admin code # new admin code # Change admin code 999999 Read card / Input a Set admin add card or admin add fingerprint twice * fingerprint Read card / Input a Set admin delete card or admin fingerprint twice * delete fingerprint 0# Reader mode 1# Standalone access control mode 1 2# Relay toggle mode Input a fingerprint twice, ... * Add fingerprint users continuously Press ID number # Input a fingerprint twice ... * Input a fingerprint once ... * Input the 2nd fingerprint ... * Press ID number # ... * Add fingerprint users by specific ID number Delete fingerprint users continuously Delete users by the specific ID number "..." means repeating the previous operation, Press * key to exit. 0000# Delete ALL users 0# (1-99)# Alarming time sets 0S, means no alarm 0 Alarming time range: 1-99 min (0-255)# (26-58)# Set device number 0 Wiegand output26-58 bits 26 0# Keypad transmission format 4 bits 1# Keypad transmission format 8 bits 0 2# Virtual card number output 0# Disable light indicator 1 1# Enable light indicator 0# 63 1# (2-99)# 0# 64 1# Disable the keypad backlight 1 Enable the keypad backlight Time of keypad backlight: 2-99 sec Disable buzzer 1 Enable buzzer - 8 - 9. Admin Card Operation 9.1 Add Card Read admin add card , Read the 1st user card Read the 2nd user card ...,Read admin add card Note: The add card is used to add card users continuously and quickly. When you read the admin add card at the first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it means you have entered into add user programming, when you read the admin add card at the second time, you will hear long "BEEP" sound once and the indicator light turns red, it means you have exited the add user programming. 9.2 Delete Card Read admin delete card , Read the 1st user card Read the 2nd user card ... , Read admin delete card Note: The delete card is used to delete card users continuously and quickly. When you read the admin delete card at the first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it means you have entered into delete user programming, when you read the admin delete card at the second time, you will hear long "BEEP" sound once, the indicator light turns red, it means you have exited the delete user programming. 10. User Operation 10.1 Change the User Code Change the user code by card Press * Read card Old code # New code # New code # Note: The default code "1234" of matching card can't open the door unless revising other codes. Change the user code by fingerprint Press * Input fingerprint Old code # New code # New code # Note: The default code "1234" of matching fingerprint can't open the door unless revising other codes. Change the user code by ID number Press * ID number # Old code # New code # New code # Note: ID number has to be known from admin before changing the code, user code can't be default code "1234". 11 Other Operation 11.1 Remove Alarm Read admin card or Read valid user card or Input valid fingerprint or Press admin code # NoteWhen the alarm is activated, user can remove the alarm by reading a valid card or Input valid fingerprint or pressing valid admin code . - 9 - 11.2 Reset to Factory Default Users can reset to the factory default when the admin code is forgotten, or the default settings have been modified, operation as below: Method 1: Power off, power on, press the # key when the indicator light turn orange, hearing beep sound twice, release the # key , the admin code has been reset to 999999, factory default settings is successful. Method 2: Power off, press the exit button continuously, power on, hearing beep sound twice, the admin code has been reset to 999999, factory default settings are successful. Note: Registered user data won't be deleted when reset to factory default. - 10Microsoft Word 2019