User Manual for WL4 models including: KPFRW-2TM Stand Alone Wifi Touch Keypad, KPFRW-2TM, Stand Alone Wifi Touch Keypad, Alone Wifi Touch Keypad, Wifi Touch Keypad, Touch Keypad, Keypad

2015年产品规划会议纪要

admin

Manual WL4 KPFRW-2TM

Een WL4 KPFRW-2TM stand alone WiFi touch keypad, vingerafdruk en Mifare kaartlezer werkt met Tuya app geschikt voor buiten koop je bij WebStore4 met gratis bezorging in NL, BE en DE

Keypad Fingerprint Access Control User Manual

Manual-WL4-KPFRW-2T
Keypad Fingerprint Access Control User Manual
Please read and understand this instruction completely before installation or operation
- 1 -

1. Introduction
This series'product is a new generation of multi-function standalone access control. It adopts new ARM core 32-bit microprocessor design, which is powerful, stable and reliable. It contains reader mode and standalone access control mode etc.. It's widely applied to different occasions, such as office, residential communities, villa, bank and prison etc..
2. Features
 Read 125KHz EM Card and HID Card (Optional)  Read 13.56MHz Mifare card and CPU card (Optional)  Metal backlight keypad  Contain reader mode, the transmission format could be adjusted by user.  Support seven access ways  Support admin add card and admin delete card  10,000 card/pin users and 600 fingerprint users.
3. Technical Specifications
 Operating Voltage: DC 12-24V  Standby Current: 35mA  Operating Current: 100mA  Operating Temperature: -40~60  Operating Humidity: 0%~95%  Access ways: Fingerprint, card, code, or multiple combination methods
4. Installation
 Remove the back cover from the keypad using the supplied special screw driver  Drill 2 holes on the wall for the self-tapping screws and I hole for the cable  Put the supplied rubber bungs to into the two holes  Fix the back cover firmly on the wall with 2 self tapping screws  Thread the cable through the cable hole  Attach the keypad to the back cover. (See the figure below)
- 2 -

5. Wiring

No. Color
1 Green 2 White 3 Grey 4 Yellow 5 Brown 6 Red 7 Black 8 Blue 9 Purple 10 Orange

Marks
D0 D1 ALARM OPEN/ BEEP D_IN/ LED +12V GND NO COM NC

Description
Wiegand input (Wiegand output as reader mode) Wiegand input (Wiegand output as reader mode) Alarm signal MOS tube drain output end (optional) Exit button input end (Beeper input as reader mode) Door contact switch input (LED input as reader mode) (optional) Positive power supply or AC power supply end Negative power supply Relay NO end Relay COM end Relay NC end

6. Diagram
6.1 Common Power Supply

Note: The door contact and alarm function are optional
- 3 -

6.2 Special Power Supply
Note: The door contact and alarm function are optional
6.3 Reader Mode
- 4 -

7. Sound and Light Indication
Operation Status
Stand by Operation successful Operation failed Admin card enter programming Admin card exit programming Press digital key Press * key Press access code Read card under card plus code mode Read multi user cards Enter programming mode Enter setting status Unlocking Buzzer alarm

Light indicator
Red Green
Red indicator flash slowly Red indicator flash slowly Red indicator flash slowly Red indicator flash slowly Orange Green Red indicator flash quickly

Buzzer
Beep-- Beep-Beep-Beep Beep-Beep Beep-- Beep Beep--
Alarm

8. Admin Menu

8.1 Standalone Mode Settings

Device Management

Enter programming

Menu

00

01 Press * Admin code

#

02

(Default admin code

is "999999")

03

08 09

Operation steps

Description

Default value

New admin code # new Change admin code
admin code #

999999

Read card

Set admin add card or admin

/ Input a fingerprint twice * add fingerprint

Read card

Set admin delete card or admin

/ Input a fingerprint twice * delete fingerprint

0#

Reader mode

1#

Standalone access control 1 mode

2#

Relay toggle mode

WIFI matching

Optional

Unlocking code # (4-6 digits) Public code

- 5 -

Add and Delete Users

Enter Menu Operation steps
programming

11

Press * Admin

code # (Default admin 12

code

is

"999999") 13

Read card / Input a fingerprint twice... * Press 8 or 10 digits card
number # ... * Press ID number # read
card / Input a fingerprint twice ... * Press ID number # press 8 or 10 digits card number # ... * Press ID number # press code # ... * Read user card, input the first fingerprint twice, input the second fingerprint twice...* Press ID number # press 8 or 10 digits card number # input card quantity #

Delete users

Read card / Input a fingerprint once ... *

21

Press 8 or 10 digits card

number #... *

Press ID number # ... *

20

0000#

Description
Add card users or fingerprint users continuously Add card users by card number
Add card users or fingerprint users by specific ID number
Add card users by specific ID number and card number Add an independent user code by specific ID number
Match fingerprints to a card (Maximum 2 fingerprints)
Add conductive number card
Delete card users by reading card / Delete fingerprint users by inputting fingerprint
Delete card users by card number
Delete users by ID number Delete ALL users

Default value
"..." means repeating the previous operation, Press * key to exit.
"..." means repeating the previous operation, Press * key to exit.

- 6 -

Access Ways

Enter programming

Menu

Press * Admin code # 31 (Default admin code is "999999")
32

Operation steps
0# 1# 2# 3# 4# 5# 6# 7#
1#
2-10 #

Description

Default value

Forbidden opening door

Entry by code only

Entry by card only

Entry by card+ code/fingerprint + code

4

Entry by card, fingerprint or code

Entry by fingerprint only

Entry by fingerprint + card

Entry by multi-fingerprint / multi-card
Set door open by 1 user card/user fingerprint
1 Set door open by 2-10 user cards/user fingerprints

Advanced Settings Enter programming

Menu
41 42

Operation steps
(0-300) #
0 # (1-99) # 0#

Press * Admin code # 61 (Default admin code is "999999")
62
63
64

1#
2#
0# 1# 0# 1# (2-99) # 0# 1#

Description

Default value

Door opening time range: 0-300S 0 equals to 50mS

5

Alarming time sets 0S, means no alarm 0
Alarming time range: 1-99 min

Normal working mode

The external alarm and built-in buzzer will

work if wrong operations are over 5 times. 0

The device will be locked out for 10 min if

wrong operations are over 5 times.

Disable light indicator 1
Enable light indicator

Disable the keypad backlight

Enable the keypad backlight

1

Time of keypad backlight: 2-99 sec

Disable buzzer 1
Enable buzzer

- 7 -

8.2 Reader Mode Settings
Enter programming Menu
00 01 02 Press * Admin code # (Default admin code is 03 "999999")
11
21
20 42 51 52 Press * Admin code # (Default admin code is 53 "999999") 62

Operation steps Description

Default value

New admin code # new admin code #

Change admin code

999999

Read card / Input a Set admin add card or admin add

fingerprint twice *

fingerprint

Read card / Input a Set admin delete card or admin

fingerprint twice *

delete fingerprint

0#

Reader mode

1#

Standalone access control mode

1

2#

Relay toggle mode

Input a fingerprint twice, ... *

Add fingerprint users continuously

Press ID number # Input a fingerprint twice ... * Input a fingerprint once ... * Input the 2nd fingerprint ... *
Press ID number # ... *

Add fingerprint users by specific ID number
Delete fingerprint users continuously
Delete users by the specific ID number

"..." means repeating the previous operation, Press * key to exit.

0000#

Delete ALL users

0# (1-99)#

Alarming time sets 0S, means no

alarm

0

Alarming time range: 1-99 min

(0-255)# (26-58)#

Set device number

0

Wiegand output26-58 bits

26

0#

Keypad transmission format 4 bits

1#

Keypad transmission format 8 bits 0

2#

Virtual card number output

0#

Disable light indicator

1

1#

Enable light indicator

0# 63
1# (2-99)# 0# 64 1#

Disable the keypad backlight 1
Enable the keypad backlight Time of keypad backlight: 2-99 sec Disable buzzer
1 Enable buzzer

- 8 -

9. Admin Card Operation
9.1 Add Card
Read admin add card , Read the 1st user card Read the 2nd user card ...,Read admin add card Note: The add card is used to add card users continuously and quickly. When you read the admin add card at the first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it means you have entered into add user programming, when you read the admin add card at the second time, you will hear long "BEEP" sound once and the indicator light turns red, it means you have exited the add user programming.
9.2 Delete Card
Read admin delete card , Read the 1st user card Read the 2nd user card ... , Read admin delete card Note: The delete card is used to delete card users continuously and quickly. When you read the admin delete card at the first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it means you have entered into delete user programming, when you read the admin delete card at the second time, you will hear long "BEEP" sound once, the indicator light turns red, it means you have exited the delete user programming.
10. User Operation
10.1 Change the User Code
Change the user code by card Press * Read card Old code # New code # New code # Note: The default code "1234" of matching card can't open the door unless revising other codes.
Change the user code by fingerprint Press * Input fingerprint Old code # New code # New code # Note: The default code "1234" of matching fingerprint can't open the door unless revising other codes.
Change the user code by ID number Press * ID number # Old code # New code # New code # Note: ID number has to be known from admin before changing the code, user code can't be default code "1234".
11 Other Operation
11.1 Remove Alarm
Read admin card or Read valid user card or Input valid fingerprint or Press admin code # NoteWhen the alarm is activated, user can remove the alarm by reading a valid card or Input valid fingerprint or pressing valid admin code .
- 9 -

11.2 Reset to Factory Default
Users can reset to the factory default when the admin code is forgotten, or the default settings have been modified, operation as below: Method 1: Power off, power on, press the # key when the indicator light turn orange, hearing beep sound twice, release the # key , the admin code has been reset to 999999, factory default settings is successful. Method 2: Power off, press the exit button continuously, power on, hearing beep sound twice, the admin code has been reset to 999999, factory default settings are successful. Note: Registered user data won't be deleted when reset to factory default.
- 10


Microsoft Word 2019