Bestway Flowclear™ Filter Pump
OWNER'S MANUAL
Model Numbers: 58381/58383/58386
For support, visit: bestwaycorp.com/support
Visit the Bestway YouTube channel ▶️
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
Carefully read, understand, and follow all information in this user manual before installing and using the Filter Pump. These warnings, instructions, and safety guidelines address some common risks of water filtration systems, but they cannot cover all risks and dangers in all cases. Always use caution, common sense, and good judgment when enjoying any water activity. Retain this information for future use. If instructions are missing, search on the website www.bestwaycorp.com/support.
WARNING:
- Electric installations should follow national wiring rules.
- The pump is to be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
- The pump cannot be used while people are inside the pool.
- The supply cord cannot be replaced. If the cord is damaged, the appliance should be scrapped.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- If instructions are missed, please contact Bestway or search on the website: www.bestwaycorp.com
TECHNICAL SAFETY INSTRUCTIONS
- The appliance must be supplied by an earthed power source.
- Extension cords cannot be used.
- Do not bury the cord. Locate the cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.
- This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.
- Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of the pump.
- When working with electricity, turn the electrical power off at the circuit breaker and lock the breaker door. Failure to do so will result in increased risk of shock, injury, and possibly death.
- Do not remove the grounding prong or modify the plug in any way. Do not use adapter plugs. Consult a qualified electrician for any questions related to the validity of your plug's grounding. Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep the cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump.
- Read the instructions before using the appliance and installation/reassembly each time.
- Cleaning and user maintenance must be performed by an adult above 18 years old who is familiar with the risk of electric shock.
- It is necessary to have the plug accessible after installation of the pool.
Atmospheric conditions may affect the performance and life span of your filter pump. Unnecessary wear and tear may occur during periods of cold, heat, and exposure to sun. Whenever possible, shelter the pump from these conditions.
It is important to ensure the factory-equipped stopper plugs for the inlet and outlet ports replace the screens before removal or maintenance on the pump is attempted.
- Do not add chemicals in the filter pump.
- Do not plug or unplug the appliance if your hand is wet.
- Always unplug the appliance: on rainy days, before cleaning or other maintenance, and when leaving it unattended on holidays.
- When the appliance will not be used for a long time, such as in the winter, the pool set should be disassembled and stored indoors.
- This product is not intended for commercial use.
SAVE THESE INSTRUCTIONS
ATTACHING A BASE
IEC60335-2-41 TEST standard requires the filter pump to be vertically fixed on the ground or a base made of wood or concrete before use. The base should have two holes 9 mm in diameter, with a space of 127 mm between them for the 330GAL model. For the 530GAL model, the space should be 159 mm. For the 800GAL model, the space should be 166 mm. Attach the pump to the base using bolts and nuts. All base parts should weigh at least 18 kg to prevent the pump from accidentally falling.
Diagram Description: The diagram shows three different base configurations for the filter pump, indicating the required hole spacing (127mm, 159mm, 166mm) and the use of M8 bolts and nuts. Each base configuration requires a total weight of at least 18 kg.
SETUP
CHECK LIST
To check the parts included in the box, consult the part list inside this manual. Verify that the equipment components represent the model you intended to purchase. In case of any damaged or missing parts at the time of purchase, visit our website bestwaycorp.com/support.
CHOOSE THE CORRECT LOCATION
Place the Filter Pump on a solid and level ground, positioned on the same level as the base of the pool. If the Filter Pump is in an upper or lower position than the base of the pool, the performance and life span of the Filter Pump can be compromised. The pool and the Filter Pump should be positioned in an area with adequate drainage and easy access for maintenance operations. Never place the Filter Pump in an area that may accumulate water.
INSTALLATION
- For installation instructions, refer to the illustration steps in the manual. Drawings are for illustration purposes only and may not reflect the actual product.
- Bestway is not responsible for any damage caused to the Filter Pump due to mishandling or failure to follow these instructions.
- Ensure that the hydraulic connectors are not obstructed.
- Do not dry run the Filter Pump. Make sure both the pool's inlet and outlet valves are fully covered by water before operating the Filter Pump.
MAINTENANCE
- Make sure that the Filter Pump is unplugged before any maintenance.
- For maintenance instructions, refer to illustration steps in the manual. Drawings are for illustration purposes only and may not reflect the actual product.
- To optimize the Filter Pump performance and for sanitary reasons, it is suggested to replace the filter cartridge with a new one every two weeks.
STORAGE
- Remove all accessories. Ensure the Filter Pump, hoses, and debris screens are completely clean and dry before storage. If parts are not completely dry, mold may result.
- Before storage, remove and dispose of the filter cartridge.
- It is strongly recommended to disassemble the Filter Pump when the environment temperature is below 10°C / 50°F.
- Store the Filter Pump in a dry place with a moderate temperature between 10°C / 50°F and 38°C / 100°F.
WARRANTY TERMS
For information concerning warranty terms, visit our website at: www.bestwaycorp.com.
Parts Diagram
Component Breakdown:
- 1: Filter Housing Top
- 2: Filter Housing Bottom
- 3: Filter Cartridge
- 4: Filter Cartridge Seal
- 5: Pump Base
- 6: Pump Motor Housing
- 7: Filter Strainer
- 8: Hose Adapters
- 9: Hose Clamps
- 10: Inlet/Outlet Connectors
- 11: Power Cord
Assembly Steps:
The manual includes diagrams illustrating the assembly and installation process. These steps involve connecting hoses, attaching the pump to a base, and ensuring proper water flow.
Step 1: Connect the inlet and outlet hoses to the pool and the filter pump using the provided adapters and clamps. Ensure a secure fit.
Step 2: Attach the pump to a stable base as described in the 'Attaching a Base' section.
Step 3: Insert the filter cartridge into the housing. Ensure it is properly seated.
Step 4: Connect the power cord and plug in the pump. Ensure the pool water level is sufficient before operation.
Diagram Description: The diagrams show the assembly of the filter pump components, including the filter housing, cartridge, and motor. Subsequent diagrams illustrate the connection of hoses to the pool and pump, and the priming process which takes approximately 1 minute.