User Guide for SHURE models including: AD610, ShowLink, Access Point, AD610 ShowLink Access Point
AD610 ShowLink Access Point Print and web guide for AD610 ShowLink Access Point Version: 4.0 (2021-G)
1. READ these instructions. 2. KEEP these instructions. 3. HEED all warnings. 4. FOLLOW all instructions. 5. DO NOT use this apparatus near water. 6. CLEAN ONLY with dry cloth View
User Guides
File Info : application/pdf, 15 Pages, 618.85KB
DocumentDocumentAD610 ShowLink® Access Point Print and web guide for AD610 ShowLink Access Point Version: 4.1 (2022-A) Table of Contents AD610 ShowLink® Access Point AD610 ShowLink Access Point Features ShowLink Access Point Overview Furnished Accessories Optional Accessories ShowLink Basics ShowLink Channels and 2.4 GHz Spectrum Coverage Area Device Capacity Device Control 2.4 GHz Channel Agility to Avoid Interference ShowLink Icon Power Power Over Ethernet External Power Supply (Optional) Shure Incorporated Networking 7 3 Reset Option 7 3 3 Positioning the Access Point 7 3 Network Mode 9 5 Control and Configure the Access Point with Wireless Workbench 9 5 Setting Power Levels 10 5 Contact Customer Support 10 5 6 Specifications 10 6 Certifications 12 6 6 IMPORTANT SAFETY INSTRUCTIONS 13 6 Important Product Information 14 6 LICENSING INFORMATION 15 6 Information to the user 15 7 2/15 Shure Incorporated AD610 ShowLink® Access Point AD610 ShowLink Access Point The AD610 ShowLink access point enables real-time remote control of all ShowLink-enabled AxientTM devices, including both digital and analog models. The access point allows comprehensive management of device parameters from the receiver or Wireless Workbench® using 2.4 GHz wireless network communication. All parameter changes occur without interruption to the performer. Multiple access points can extend the operational range or increase the number of devices supported on the ShowLink net work. The access point also features true diversity antenna inputs. Features · Real-time wireless remote control of up to 24 devices per ShowLink access point · New RF design and true diversity antenna scheme for improved link performance · Easy device authentication--Recognizes linked devices upon IR sync · Automatic hand-offs between multiple access points extend operating range · Automated channel selection--Independently scans 2.4 GHz frequency range and determines best channel for use · Automatic frequency agility--Moves a ShowLink network to the best available 2.4 GHz channel in the event of signal degradation · Wireless Workbench software supports networked control of all device functions and provides a ShowLink plot for viewing 2.4 GHz signal levels · Receives power via Power over Ethernet (PoE) network connection or from an external power supply · Versatile mounting options--Fits microphone stand adapters and has builtin ¼"20 and M6 x 1.0 threading for installation · Backwards compatible with Axient analog transmitters and receiver 3/15 ShowLink Access Point Overview Shure Incorporated ShowLink 2.4 GHz detachable antennas For 2.4 GHz signals ShowLink Data Status LED (blue) ON Steady: Linked, no data transmission Flashing: Transmitting data. Rate of flashing indicates level of activity Power Status LED (green/amber/red) Steady Green: Power ON, power source = PoE Steady Amber: Power ON, power source = external power supply Red Flashing: Response to remote ID flash command Ethernet Status LED (green) ON Steady: Ethernet connected, no traffic ON Flashing: Ethernet connected, flashing corresponds to volume of data traffic ¼"-20 threaded mounting point Use to wall-mount the access point 4/15 External power supply connector Connection point for external power supply Reset button Press to restore factory settings Ethernet port For network connection and Class 1 PoE Scanning antenna for channel agility Scans the 2.4 GHz spectrum for the best frequency M6 x 1.0 threaded mounting point Use to mount access point to safety cable Shure Incorporated Furnished Accessories Note: Model availability depends on region. See your local Shure dealer or distributor for details. WA371 31A1856 95A15104 PS43 Optional Accessories Directional 2.4 GHz patch antenna AXT644 (available depending on regional regulations) ShowLink Basics ShowLink Channels and 2.4 GHz Spectrum ShowLink channels that enable remote control of Axient devices operate in the 2.40 to 2.484 GHz portion of the RF spectrum in accordance with the IEEE 802.15.4 protocol. Devices that share the 2.4 GHz spectrum, including Wi-Fi, are manufactured to efficiently share the spectrum and cause minimal interference. Both ShowLink and Wi-Fi use "listen before talk" technology to transmit short message packets only when needed to conserve bandwidth. Available spectrum, low interference, and global availability make the 2.4 GHz spectrum an ideal choice for hosting ShowLink channels. Within the 2.4 GHz spectrum, 16 channels are available for ShowLink communication. To ensure reliable communication, the access point contains an internal scanning radio that analyzes the 2.4 GHz spectrum hundreds of times per second. If interfer ence is detected, the access point uses channel agility to automatically switch to a clear channel within the spectrum. All de 5/15 Shure Incorporated vices associated with the access point will continue to communicate uninterrupted on the new ShowLink channel. If ShowLink goes offline for any reason, audio transmission will not be interrupted. Coverage Area The coverage area of the access point is approximately the same as the range of the linked device. Use the ShowLink Test feature in the receiver menu to map the boundaries of the coverage area. Multiple access points can be used to increase the coverage area or to expand coverage to multiple rooms. ShowLink Test - ADX5D ShowLink Test - AD4D or AD4Q Device Capacity A single access point supports up to 24 ShowLink-enabled Axient devices, including both Axient and Axient Digital models. Any ShowLink-enabled device within range of an active access point with available capacity will be automatically controlled by that access point. When multiple access points are used to increase device capacity or coverage area, device control is automati cally divided between each access point. All changes in control between access points occur seamlessly and automatically, without requiring user intervention. Device Control An access point with available capacity will automatically control linked devices that are within the coverage area. Multiple ac cess points automatically selfmanage to divide device control and maintain coverage. Transitions between access point con trol do not affect the transmission of the audio channel. 2.4 GHz Channel Agility to Avoid Interference When interference is present from Wi-Fi or other devices sharing the spectrum, built-in channel agility automatically switches the access point and all controlled transmitters to a clear channel. Channel agility is able to avoid interference from most de vices that operate in the 2.4 GHz spectrum, such as Wi-Fi or cell phones. ShowLink Icon The ShowLink icon appears on the home screens of a linked transmitter and receiver to indicate that the transmitter is within range of an access point making remote control possible. If a device is beyond the range of the access point, or if the receiver is offline, the icon will disappear, indicating a loss of ShowLink control. Power The access point is powered through Power Over Ethernet (PoE)enabled network ports. If PoE is not available, use an exter nal power supply. Power Over Ethernet The Shure Ethernet switch and Axient rack components offer network ports with Power over Ethernet (PoE). The network port powers the access point as long as the host component is powered on. 1. Insert a Cat 5 Ethernet cable into the Ethernet port located on the body of the access point. 2. The Ethernet PoE connection supplies power for the access point. 6/15 External Power Supply (Optional) If Power over Ethernet (PoE) is not available, power the access point using an external power supply. 1. Connect the power supply to the external power supply jack. 2. Tighten the locking ring to secure the plug. 3. Plug the power supply AC line cord into an AC power source. 4. Connect a Cat 5 Ethernet cable to the access point to provide a network connection. Shure Incorporated Networking Networking the access point using a DHCP-enabled router automatically assigns an IP address, simplifying network setup. The network connection allows the access point to share data with networked components and enables wireless control of the de vices. To manually assign an IP address to the access point, use Wireless Workbench. Reset Option Pressing the reset button located on the bottom of the housing restores the access point to the following settings: · IP Address Mode = DHCP · Channel Agility = Enabled · Device ID = AD610 · Device Association Tables will be cleared 7/15 Shure Incorporated Positioning the Access Point · Provide a clear line of sight between the access point and devices. Mount the access point on a microphone stand or wall to elevate above obstructions. · Position the antennas vertically for optimal performance. The swivel joint on each antenna allows a wide range of position ing to maintain a vertical alignment. · If possible, move access point farther from other 2.4 GHz devices. · This product is intended to be mounted with a ¼"-20 threaded insert and installed by a qualified person with suitable mounting means as appropriate for wall surface chosen. Microphone Stand Mount Horizontal Mount 8/15 Shure Incorporated Wall Mount Network Mode Set a host ID on the AD610 to connect to an ADX5D portable receiver in network mode. An AD610 with a host ID set grants ac cess to ADX5Ds with a matching client ID. 1. Update your AD610 to the latest firmware and download the latest version of Wireless Workbench. 2. Connect the access point to your network using a Class 1 Power over Ethernet (PoE) port. 3. Right-click the device in Wireless Workbench and open the device properties. 4. Set a ShowLink network host ID (e.g. A.B.C.D). Repeat this process for any other AD610s you have on the network that you want to act as a gateway for an ADX5D. Then, set the client ID on your ADX5D. Control and Configure the Access Point with Wireless Workbench Using Wireless Workbench, you can do the following for your AD610. · Edit device ID · View connected devices · View device capacity · Disable channel agility for troubleshooting · Set IP address mode: DHCP or manual · Set IP address: Edit in manual address mode · View and set subnet mask · View MAC address 9/15 Tip: The text color of the device ID for each transmitter in the Connected list indicates link quality: · Green = Excellent · Yellow = Good · Red = Marginal Hovering the cursor over the Device ID displays link quality ranked from 5 to 1. Shure Incorporated Setting Power Levels To adjust the power level, use Wireless Workbench. In locations with many competing 2.4 GHz sources, operating at a higher power level improves ShowLink performance and may extend range. · Normal (default) = Operates at 8 dBm · High = Operates at 18 dBm 1. Open the Properties panel for the access point in Wireless Workbench. 2. Click the Settings arrow, and select Network. 3. Choose a power level and click Apply. Note: · Always check regional regulations before operating in the high power setting. · Due to regulations, Channel 26 can only operate in the normal power setting. Contact Customer Support Didn't find what you need? Contact our customer support to get help. Specifications General Antenna Type 2 Omnidirectional 2.4 GHz Capacity 24 Axient ShowLink devices (AXT or ADX models) Mounting Type WA371 Mic Clip or 1/4-20 thread mount Operating Temperature Range -18°C (0°F) to 60°C (140°F) Storage Temperature Range -29°C (-20°F) to 74°C (165°F) 10/15 Shure Incorporated Dimensions 190 mm x 102 mm x 47 mm (7.48 in. x 4 in. x 1.85 in.) H x W x D, without antennas Weight 464 g (16.3 oz.), without antennas Housing Extruded Aluminum Power Requirements Power over Ethernet (PoE) Class 1 External Power Supply (if PoE is unavailable) Ingress Protection Rating IPX3 36 to 57 V DC/V AC 15 V DC (600 mA), double insulated ShowLink Network Type IEEE 802.15.4 Frequency Range 2.40 to 2.4835 GHz (16 channels) RF Output Power 10 dBm ERP / 20 dBm ERP (dependent on applicable country regulations) Working Range Under typical conditions Line of Sight, outdoors for a single system 150 m ( 500 ft) 500 m ( 1600 ft) Note: Actual range depends on RF signal absorption, reflection and interference.Note: Actual range depends on RF signal ab sorption, reflection and interference. Antenna Connection Connectors 2 SMA (Shell=Ground, Center=Signal) Impedance 50 11/15 Scanning Radio Scanner RF Sensitivity 106 dBm, typical (integrated antenna) Networking Network Interface Ethernet 10/100 Mbps Network Addressing Capability DHCP or Manual IP address (configurable using Wireless Workbench) Shure Incorporated Certifications Meets essential requirements of the following European Directives: · WEEE Directive 2012/19/EU, as amended by 2008/34/EC · RoHS Directive EU 2015/863 Note: Please follow your regional recycling scheme for batteries and electronic waste This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking. CE Notice: Hereby, Shure Incorporated declares that this product with CE Marking has been determined to be in compliance with European Union requirements. The full text of the EU declaration of conformity is available at the following site: https:// www.shure.com/en-EU/support/declarations-of-conformity. Authorized European representative: Shure Europe GmbH Department: Global Compliance Jakob-Dieffenbacher-Str. 12 75031 Eppingen, Germany Phone: +49-7262-92 49 0 Fax: +49-7262-92 49 11 4 Email: EMEAsupport@shure.de Meets requirements of the following standards: EN 300 328 EN 301 489 Parts 1 and 17 IEC60950 Certified under FCC Part 15. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device contains licenceexempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Develop ment Canada's licenceexempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. 12/15 Shure Incorporated L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Certified by ISED in Canada under RSS-247. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, hav ing a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. FCC ID: DD4AD610. IC: 616A-AD610. Canada Warning for Wireless This device operates on a noprotection, nointerference basis. Should the user seek to obtain protection from other radio ser vices operating in the same TV bands, a radio licence is required. For further details, consult Innovation, Science and Econom ic Development Canada's document Client Procedures Circular CPC2128, Voluntary Licensing of LicenceExempt LowPow er Radio Apparatus in the TV Bands. Ce dispositif fonctionne selon un régime de nonbrouillage et de nonprotection. Si l'utilisateur devait chercher à obtenir une certaine protection contre d'autres services radio fonctionnant dans les mêmes bandes de télévision, une licence radio serait requise. Pour en savoir plus, veuillez consulter la Circulaire des procédures concernant les clients CPC2128, Délivrance de licences sur une base volontaire pour les appareils radio de faible puissance exempts de licence et exploités dans les bandes de télévision d'Innovation, Sciences et Développement économique Canada. Transmitters must be installed to provide a minimum separation distance of 20 cm from all persons. Note: EMC conformance testing is based on the use of supplied and recommended cable types. The use of other cable types may degrade EMC perfor mance. IMPORTANT SAFETY INSTRUCTIONS 1. READ these instructions. 2. KEEP these instructions. 3. HEED all warnings. 4. FOLLOW all instructions. 5. DO NOT use this apparatus near water. 6. CLEAN ONLY with dry cloth. 7. DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance with the manufacturer's instructions. 8. DO NOT install near any heat sources such as open flames, radiators, heat registers, stoves, or other apparatus (in cluding amplifiers) that produce heat. Do not place any open flame sources on the product. 13/15 Shure Incorporated 9. DO NOT defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replace ment of the obsolete outlet. 10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. ONLY USE attachments/accessories specified by the manufacturer. 12. USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. UNPLUG this apparatus during lightning storms or when unused for long periods of time. 14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus. 16. The MAINS plug or an appliance coupler shall remain readily operable. 17. The airborne noise of the Apparatus does not exceed 70dB (A). 18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connec tion. 19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 20. Do not attempt to modify this product. Doing so could result in personal injury and/or product failure. 21. Operate this product within its specified operating temperature range. Explanation of Symbols Caution: risk of electric shock Caution: risk of danger (See note.) Direct current Alternating current On (Supply) Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION Stand-by Equipment should not be disposed of in the normal waste stream WARNING: Voltages in this equipment are hazardous to life. No userserviceable parts inside. Refer all servicing to qualified service personnel. The safety cer tifications do not apply when the operating voltage is changed from the factory setting. 14/15 Shure Incorporated Important Product Information LICENSING INFORMATION Licensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user's responsibility, and licensability de pends on the user's classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies. Information to the user This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa tion. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and the receiver. · Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. 1. 2. 3. Shure http://www.shure.co.jp 2.4GHz DS 40m 2,400MHz 2,483.5MHz 15/15