Installation Guide for nedap models including: Transit Ultimate Reader, Ultimate Reader, Reader
Nedap | ADI Global
File Info : application/pdf, 12 Pages, 4.31MB
DocumentDocumentMini Install Guide TRANSIT Ultimate Quick Install Sheet Out of the box, the reader is set to output Wiegand 26 with FC of 10 with Dipswitches 2, 6, and 7 "OFF". Can be changed at the reader level. Power Supply: Linear 24vdc 2-3 AMP Cabling: Shielded twisted 6 (18-22 Gauge) for communication wiring. A separate pair (14-18 Gauge) for the power supply. Wiring and Communication: Data Ground D0 (Green) D1 (White) GND above 0-1 0-2 0-3 Grounding: Access Control Panel Wiegand Communication Data 0 - Green Data 1 - White Ground - Black Auxiliary bridge wire needed for proper grounding Linear Power Supply 24VDC 2-3 Amp Main Power to Access Panel Continuity is created by landing a jumper between the 12v ground powering the access control panel to the 24v ground powering the reader. Additional Resources: portal.nedapidentification.com Orientation: Horizontally (normal application) the reader emits an 80-degree wide by 40-degree high oval beam. Vertically the reader emits a 40-degree wide by 80-degree high beam. This is recommended for multi-lane applications to prevent cross talk. Tag Enrollment: Out of box the reader is set to output W26 with the FC of 10. The orange circle is the 6-digit W35 or higher ID number. The blue circle is the 5-digit W26 ID number. Do not include the dash or number after the dash. Installation Height: Best practice is to mount the reader 4-6 ft above the highest tag placement and angle the reader down and across (45 degrees) the read lane. Tag Placement: Metalized content will block tag signals. Best practice is to utilize external mount tags for this occurrence. 8.5 - 10 ft. Window Button Window Button with switch Quick Shots: · OSDP Installation Pages 13-15 Install Guide Prox Booster Single and Dual ID, Smart Card, & End2End Heavy Duty Tag uPASS Target Quick Install Sheet Out of the box, the reader is set to maximum read range and to output Wiegand Protocol. See manual for additional communication options. Power Supply: Linear 24vdc 2-3 AMP Cabling: Shielded twisted 6 (18-22 Gauge) for communication wiring. A separate pair (14-18 Gauge) for the power supply. Wiring: Communication: Power: Grounding: Conn 5 Access Control Panel Wiegand Communication Data 0 - Green Data 1 - White Ground - Black Auxiliary bridge wire needed for proper grounding Linear Power Supply 24VDC 2-3 Amp Main Power to Access Panel Continuity is created by landing a jumper between the 12v ground powering the access control panel to the 24v ground powering the reader. Additional Resources: portal.nedapidentification.com Tag Enrollment: Stock Tags indicate their programming and facility code on the box within the description UHF W26 FC:020). Special Programmed Tags indicate their programming and facility code on the submitted order. You will be able to go in and enroll your tags with the information provided with your order. Stock Tag Preconfigured W26 with Facility Code Special Programmed Tags Special Order Installation Height: Best practice is to mount the reader 4-6 ft above the highest tag placement and angle the reader down and across (45 degrees) the read lane. Tag Placement: Metalized content will block tag signals. Best practice is to utilize external mount tags for this occurrence. 8.5 - 10 ft. Windshield Sticker Tag Hang Tag Exterior Sticker Tag Exterior Heavy-Duty Tag Quick Shots: · OSDP Installation Pages 13-15 Install Guide · UHF Windshield Tags and Exterior Tag Installation sheets (available on our Partner Portal for download.) uPASS Reach Quick Install Sheet Out of the box, the reader is set to maximum read range and to output Wiegand Protocol. See manual for additional communication options. Power Supply: Linear 24vdc 2-3 AMP Cabling: Shielded twisted 6 (18-22 Gauge) for communication wiring. A separate pair (14-18 Gauge) for the power supply. Wiring and Communication: D0 (Green) D1 (White) Data Ground OUT-2 OUT-3 GND DC+ (Red) DC- (Black) Grounding: Access Control Panel Wiegand Communication Data 0 - Green Data 1 - White Ground - Black Auxiliary bridge wire needed for proper grounding Linear Power Supply 24VDC 2-3 Amp Main Power to Access Panel Continuity is created by landing a jumper between the 12v ground powering the access control panel to the 24v ground powering the reader. Additional Resources: portal.nedapidentification.com Tag Enrollment: Stock Tags indicate their programming and facility code on the box within the description UHF W26 FC:020). Special Programmed Tags indicate their programming and facility code on the submitted order. You will be able to go in and enroll your tags with the information provided with your order. Stock Tag Preconfigured W26 with Facility Code Special Programmed Tags Special Order Installation Height: Best practice is to mount the reader 4-6 ft above the highest tag placement and angle the reader down and across (45 degrees) the read lane. Tag Placement: Metalized content will block tag signals. Best practice is to utilize external mount tags for this occurrence. 8.5 - 10 ft. Windshield Sticker Tag Hang Tag Exterior Sticker Tag Quick Shots: · Other communication wiring setups Pages 17 &18 of the Installation Guide. · OSDP Installation Pages 19-20 Installation Guide. · Dipswitch settings Pages 27-29 of the Installation Guide. Exterior Heavy-Duty Tag Want To Stand Out? What Are You Waiting For? · Brand Visibility · Personalized · Enhanced Security · Streamlined Operations · Professional Image · Improved Experience · Hang Tags · Sticker Tags Scan the QR Code to set up a training on how Customize Your Business helps you stand out, grow your business, and your visibility! Customization Made Easy Your Business, Your Logo, Your Narrative Login Upload Design ! WhatYou've Waiting For Revolutionize Your Business starting at the gate by creating customized Nedap RFID hangtags and sticker tags tailored with your narrative. Been LPR LUMO Quick Install Sheet The software is embedded in the camera. No additional license fees. See manual for additional wiring information. Power Supply: Linear 24vdc 2-3 AMP Cabling: Shielded twisted 6 (18-22 Gauge) for communication wiring. A separate pair (14-18 Gauge) for the power supply. Wiring: The LUMO comes with a wiring harness and network connection from the reader. Grounding: Access Control Panel Wiegand Communication Data 0 - White Data 1 - Brown Ground - Purple Auxiliary bridge wire (connect negative terminals) Power Supply 24VDC DC Power Ground Main Power to Access Panel 24v+ Red Power GND Black Relay Output 1 Relay Output 2 Data 0 White Data 1 Brown Data Ground Purple Continuity is created by landing a jumper between the 12v ground powering the access control panel to the 24v ground powering the reader. Additional Resources: portal.nedapidentification.com Connecting to the LUMO: Default address is 192.168.3.15. Default username is "admin" and the password is "secret". This will bring you to be able to set up and configure the reader using an easy-to-use web interface. More details are in the installation guide. Installation Height: Best practice is to mount the reader at license plate height (can be installed up to 14 ft high) and no greater angle than 25 degrees down a single lane. If the State does not require front plates the same applies but pointing towards the back plate. Max Angle 25 degrees Sweet Spot is 6.5-33ft from the reader Max Angle 25 degrees Scan the QR Code for additional resources.