DocumentDocumentNuvair LP-LP 12 Nitrox Generator QuickStart Guide SKU 7068 Series Rev. 04.2025 Quick Start Guide Compressor Operation STEP 1: Pre-Start Inspection Check the following before starting: · Air intakes are on and connected · Pumps and motor have oil and are full · Gas tank is full · Filters are in place · Battery is connected STEP 2: Starting the Compressor · If using an R-15 pump with head unloaders, set head unloader toggle to horizontal (unloaded) · When cold, pull the choke out before turning the key · For the first 1015 seconds: o Keep choke on o Keep pump unloaded · Then: o Slowly push the choke in o Flip the unloader valve toggle to begin building pressure STEP 3: Analyzer Setup & Warm-Up · Turn on analyzers and calibrate to 20.9% · Use the regulator (turn clockwise) to build pressure to 80100 psi · Heater thermostat will activate--warm up for 2030 minutes · Adjust regulator to reach desired gas mix % STEP 4: Shutting Down · Flip up unloader valve toggle to unload and cool down (1520 seconds) · Turn the key off · Turn off analyzers Nuvair Page 2 www.Nuvair.com