Instruction Manual for JIREH models including: CKA008 ODI Single Probe, CKA008, ODI Single Probe, Single Probe

JIREH Industries


File Info : application/pdf, 2 Pages, 362.34KB

PDF preview unavailable. Download the PDF instead.

CK0045-ODI User Manual GsRwk4r
6 SPARE PARTS

1

5

4

2 3
9

6
7 8

BOM ID Part #

Description

1 CKA008-X-Y Base ODI - Single Probe (see Encoder Connector Type) (alternate cable lengths)

2 CKS012

Adjustable Clamp Arm

3 CK0018

Clamp Arm, 70 mm (2.8 in) (alternate arm lengths available)

4 CKS020

ODI Encoder Mount, with Clamp Arm: 70 mm (2.8 in)

5 CKS007-X-Y Encoder Brick Replacement (see Encoder Con. Type) (alternate cable lengths)

6 CKS016

Rubber Encoder Wheel

7 MD307-010 FHMS, M2.5x0.45 X 10mm SST PHILLIPS

8 CKS011-X-Y ODI Spring-Loaded Encoder (see Encoder Con. Type) (alternate cable lengths)

9 CK0064

Heat Treated Stainless Steel Encoder Wheel

6.1. Encoder Connector Type

Connector Type B C
E F

Company/Instrument
Olympus OmniScan MX Zetec Topaz Olympus Focus LT Zetec Z-Scan Eddyfi Ectane 2 Olympus OmniScan SX/MX2/X3 M2M MANTIS/GEKKO LEMO TD (Technology Design)

Connector Type G
U

Company/Instrument Sonotron Isonic 25xx Sonatest Veo / Prisma

V

Pragma PAUT

AD

Sonatest Veo / Prisma - Single Axis

53158 Range Road 224, Ardrossan, Alberta, Canada, T8E 2K4 | info@jireh.com | 780.922.4534 jireh.com

ODI
CK0045 Rev 05.6 Modular Encoder

1 SPECIFICATIONS

1.1. Intended Use
The ODI is a clamp-on mini encoder. It is designed to provide encoded linear position of probes in manual scanning operations.

1.2. Performance Specifications

Wedge Width: Encoder Resolution:

0 - 55 mm (2.16 in) 16.00 counts/mm (406.4 counts/inch)

Environmental Sealing:

Watertight (submersible), Contact JIREH for details

1.3. Operating Environment
The ODI is designed for use in an industrial environment that is between -20°C (-4°F) and 50°C (122°F).
2 PREPARATION FOR USE

2.1. Probe Attachment

Fig. 1 - Loosen slider knob, move clamp arm
2.2. Encoder Setup

Fig. 2 - Tighten slider knob

Fig. 3 - Tighten clamping knob

Fig. 4 - Release pivot knob

Fig. 5 - Lower encoder wheel to surface

Fig. 6 - Tighten pivot knob

2.3. Alternate Encoder Position

Fig. 7 - Unscrew pivot knob and remove encoder

Fig. 8 - Tighten pivot knob and follow steps 2.2.

3 OPERATION
Hold the wedge flat against the scanning surface and scan straight in the desired direction, ensuring that the encoder wheel is in contact with the scanning surface and is rotating in the direction of the scan.

4 MAINTENANCE
Wipe the scanner clean as required. Do not soak or submerge the scanner in a cleaner or solvent of any kind.

5 TROUBLESHOOTING

Problem
Encoder not incrementing

Possible Cause

Solution

Encoder wheel, not in contact Rotate the pivot joint until the wheel is in

with scanning surface.

contact with the scanning surface and the

spring joint is slightly depressed (see 2.2)

Encoder wheel is not running Unscrew the pivot knob separating the

in the desired scanning

encoder. Place the encoder in an alternate

direction.

encoder position (see 2.3).

Encoder connector is not correctly connected to a scanning device.

Check the scanning device's instructions on properly connecting an encoder.



References