Instruction Manual for JIREH models including: CKA008 ODI Single Probe, CKA008, ODI Single Probe, Single Probe
File Info : application/pdf, 2 Pages, 362.34KB
DocumentDocument6 SPARE PARTS 1 5 4 2 3 9 6 7 8 BOM ID Part # Description 1 CKA008-X-Y Base ODI - Single Probe (see Encoder Connector Type) (alternate cable lengths) 2 CKS012 Adjustable Clamp Arm 3 CK0018 Clamp Arm, 70 mm (2.8 in) (alternate arm lengths available) 4 CKS020 ODI Encoder Mount, with Clamp Arm: 70 mm (2.8 in) 5 CKS007-X-Y Encoder Brick Replacement (see Encoder Con. Type) (alternate cable lengths) 6 CKS016 Rubber Encoder Wheel 7 MD307-010 FHMS, M2.5x0.45 X 10mm SST PHILLIPS 8 CKS011-X-Y ODI Spring-Loaded Encoder (see Encoder Con. Type) (alternate cable lengths) 9 CK0064 Heat Treated Stainless Steel Encoder Wheel 6.1. Encoder Connector Type Connector Type B C E F Company/Instrument Olympus OmniScan MX Zetec Topaz Olympus Focus LT Zetec Z-Scan Eddyfi Ectane 2 Olympus OmniScan SX/MX2/X3 M2M MANTIS/GEKKO LEMO TD (Technology Design) Connector Type G U Company/Instrument Sonotron Isonic 25xx Sonatest Veo / Prisma V Pragma PAUT AD Sonatest Veo / Prisma - Single Axis 53158 Range Road 224, Ardrossan, Alberta, Canada, T8E 2K4 | info@jireh.com | 780.922.4534 jireh.com ODI CK0045 Rev 05.6 Modular Encoder 1 SPECIFICATIONS 1.1. Intended Use The ODI is a clamp-on mini encoder. It is designed to provide encoded linear position of probes in manual scanning operations. 1.2. Performance Specifications Wedge Width: Encoder Resolution: 0 - 55 mm (2.16 in) 16.00 counts/mm (406.4 counts/inch) Environmental Sealing: Watertight (submersible), Contact JIREH for details 1.3. Operating Environment The ODI is designed for use in an industrial environment that is between -20°C (-4°F) and 50°C (122°F). 2 PREPARATION FOR USE 2.1. Probe Attachment Fig. 1 - Loosen slider knob, move clamp arm 2.2. Encoder Setup Fig. 2 - Tighten slider knob Fig. 3 - Tighten clamping knob Fig. 4 - Release pivot knob Fig. 5 - Lower encoder wheel to surface Fig. 6 - Tighten pivot knob 2.3. Alternate Encoder Position Fig. 7 - Unscrew pivot knob and remove encoder Fig. 8 - Tighten pivot knob and follow steps 2.2. 3 OPERATION Hold the wedge flat against the scanning surface and scan straight in the desired direction, ensuring that the encoder wheel is in contact with the scanning surface and is rotating in the direction of the scan. 4 MAINTENANCE Wipe the scanner clean as required. Do not soak or submerge the scanner in a cleaner or solvent of any kind. 5 TROUBLESHOOTING Problem Encoder not incrementing Possible Cause Solution Encoder wheel, not in contact Rotate the pivot joint until the wheel is in with scanning surface. contact with the scanning surface and the spring joint is slightly depressed (see 2.2) Encoder wheel is not running Unscrew the pivot knob separating the in the desired scanning encoder. Place the encoder in an alternate direction. encoder position (see 2.3). Encoder connector is not correctly connected to a scanning device. Check the scanning device's instructions on properly connecting an encoder.