Instruction Manual for PCE Instruments models including: PCE-DM 3, PCE-DM 3 Digital Multimeter, PCE-DM 3, Digital Multimeter, Multimeter

打印

PCE-DM 3

5 апр. 2025 г. — When using this instrument, the user must follow all standard safety procedures regarding: 1.Safety regulations to prevent electric shock. 2.To ensure your ...


File Info : application/pdf, 17 Pages, 853.55KB

PDF preview unavailable. Download the PDF instead.

man-digital-multimeter-pce-dm-3-en
PCE-DM 3
Digital Multimeter
Instruction Manual

CATALOG
1. Introduction 2.Safety Instructions 3.Instrument Description 4.Operation Instructions 5.Technical Indicators 6.Instrument Maintenance 7.Production Information

Notice to user
Please read this instruction manual and operation instructions carefully,Follow the instructions in the manual,In order to make the detector function fully. Please keep this manual. Dont use this equipment in a flammable and explosive environment. Replaced used batteries and discarded instruments cannot be disposed of with household waste.Please handle according to relevant national or local laws. When there are any quality problems with the instrument or questions about
using the instrument.You can contact PCE Instruments online customer service.
1.Introduction
This product is a handheld large-screen digital display smart multimeter. It has the advantages of fast measurement data, large-screen LCD dual display, lighting, and easy reading by users. It has functions such as overload protection and battery undervoltage indication. Whether it is used by professionals, factories, schools, hobbyists or families, it is a rational think of the multi-function instrument. It belongs to secondary pollution, and the overvoltage standard is CAT III 1000V.
2.Safety Instructions
When using this instrument, the user must follow all standard safety procedures regarding: 1.Safety regulations to prevent electric shock 2.To ensure your personal safety, please use the test pen provided with the meter. To ensure your personal safety, use the test pens provided with the meter. Before use, check and make sure they are in good condition.
14

1.Safety Precautions
Use the meter near the equipment with large electromagnetic interference, the reading of the meter will be unstable, and even may produce larger errors. Do not use when the appearance of the meter or test leads is damaged. If the instrument is not used correctly, the safety function provided by the instrument may be invalid.  Extreme care must be taken when working around exposed conductors or busses. It is forbidden to use this instrument near explosive gas, steam or dust. The correct input terminal, function and range must be used for measurement. The input value must not exceed the input limit value specified in each range to prevent damage to the instrument. When the meter is connected to the line under test, do not touch the unused input terminals. When the measured voltage exceeds the rms value of 60V DC or 30V AC, be careful to prevent electric shock. When measuring with a test pen, place your finger behind the protective ring of the test pen. Before changing the range, make sure that the test pen has left the circuit under test. For all DC functions, in order to avoid the risk of electric shock due to possible incorrect readings, please use the AC function first to confirm whether there is any AC voltage. Then, select a DC voltage range that is equal to or greater than the AC voltage. Before performing resistance measurement or continuity test, the power supply of the circuit under test must be cut off, and all high-voltage capacitors in the circuit under test must be discharged. Do not measure resistance or conduct continuity tests on live circuits. Do not put it in an explosive and flammable place when not in use. When repairing TV sets or measuring power conversion circuits, be careful of high-amplitude voltage pulses in the circuit under test to avoid damage to the meter.
15

This product uses 3.7V/1000mA lithium battery for power supply, and the battery must be correctly installed in the battery box of the instrument. When the battery undervoltage symbol appears, please charge it in time. A low battery can cause the meter to read incorrectly, which could result in electric shock or personal injury. In the measurement category, the voltage measurement should not exceed 1000V. The case of the instrument (or part of the case | do not use the instrument when it is removed).
2. Safety Maintenance Habits
When opening the case of the instrument or removing the battery cover, the test pen should be pulled out first. When repairing the instrument, be sure to use the designated replacement parts. Before turning on the instrument, you must disconnect all related power sources, and you must also ensure that you do not have static electricity to prevent damage to the components of the instrument. The calibration and maintenance of the instrument can only be returned to the factory for maintenance. When opening the case of the meter, it must be noted that some capacitors in the meter still hold dangerous voltages even after the meter is powered off. If any abnormality is observed in the instrument, the instrument should be stopped immediately and sent for repair. And make sure that it cannot be used until it passes the inspection. When not in use for a long time, and avoid storing in places with high temperature and high humidity.
3. Input protection measures
When performing voltage measurement, the maximum input voltage that can withstand is DC voltage 1000V or AC Voltage 1000V. Can withstand no more than 250V AC voltage or equivalent effective value voltage.
16

3.Instrument Description

12

11

3

5

7

6

8

9

10

1 Charging port (5V-1A) 2 Charging indicator
(red light for charging, green light for full) 3 On/Off Button

4 flashlight

9 black test pen input

5 LCD Monitor

10 red test pen input

6 NCV and LIVE buttons 11 NCV sensing area

7 SEL button

8 Data hold and flashlight buttons

17

Button description

Button

Function Description power button Function switch button Data hold button and flashlight NCV function and Firewire function buttons

4.Operation Instructions

æRegular operation

Reading Hold Mode keeps the current reading on the display. The reading hold

mode can be exited by changing the measurement function gear or pressing the

key again. To enter and exit reading hold mode:

1. Short press the"

"key,the reading will be held and the symbol will be

displayed on the LCD HOLD display at the same time.

2. Short press the "

" key again to restore the meter to the normal measure-

ment state.3. Long press "

" to turn on the flashlight, and then long press

to turn off the flashlight.

3. Press the "

" key to perform NCV measurement. Press the "

" key

again to enter the live wire (LIVE) measurement.

18

çAutomatic measurement
Note
Do not measure any voltage higher than 1000V DC/1000V AC to prevent electric shock or damage to the instrument. Do not apply more than 1000V DC voltage/1000V AC voltage between the common terminal and the ground to avoid electric shock or damage to the instrument.
In automatic mode, AC and DC voltage, resistance and continuity can be automatically measured. 1. After power on, it will automatically switch to "AUTO" automatic measurement mode. 2. Connect the black test lead and the red test lead to the COM input jack and the INPUT input jack respectively. 3. Use the test pen to measure the voltage value, resistance value and short-circuit point of the circuit to be tested at both ends. (parallel to the circuit under test) 4. At this time, the liquid crystal display will display the corresponding measured voltage value and resistance value at the same time. When measuring DC voltage, the display will show the voltage polarity connected to the red test lead at the same time. If the measured resistance value is less than 50, the buzzer will issue an alarm sound.
Notice
When the measured DC voltage is less than 0.75V and the AC voltage is less than 0.75V, the displayed resistance value may appear, because the minimum measurement voltage value of this product is 0.75V, and the minimum AC voltage is 0.75V.
1. When measuring low resistance, in order to measure accurately, please first short-circuit the two test leads to read the short-circuit resistance value of the test leads, and subtract the resistance value after measuring the measured resistance.
19

2. In the 10M range, it will take a few seconds for the reading to stabilize. This is normal for high resistance measurements. 3. When the meter is open circuit or the resistance value of the measured object is too large, the display will display "OL", indicating that the measured value exceeds the range

èNCV test

Press the key ,place the top of the meter close to the conductor, if the meter

detects AC voltage, the meter will The signal strength of , when the sensed

voltage is low , the screen signal will display low:

, medium:

,

high:

, and at the same time the buzzer emits alarm sounds of

different frequencies.

Notice
Even without indication, voltage may still be present. Do not rely on non-contact voltage detectors to determine lead Whether there is voltage on the line. Probing operations may vary by socket design, insulation thickness and type, etc. influence of factors. When the input terminal of the meter enters the voltage, the buzzer will also sound due to the existence of the induced voltage. sound. Interference sources in the external environment (such as flashlights, etc.) may falsely trigger the non-contact voltage detection.

20

éFirewire test

Press

press the button twice, the screen displays LIVE, insert the red test

pen into the INPUT end, and the red pen into the power socket, the meter

displays LIVE, which is the live wire.

êDiode measurement

1. After power on, it will automatically switch to the "AUTO" automatic measure-

ment mode, and then press the SEL key to switch to the "

" diode

measurement mode.

2. Connect the black test lead and the red test lead to the COM input jack and the

INPUT input jack respectively.

3. Connect the black test lead and the red test lead to both ends of the object to

be tested.

4. If the measured object is a diode, the red and black test leads should be

placed on the positive and negative ends of the diode respectively, and the

meter will display the positive bias value of the tested diode. If the polarity of the

test leads is reversed or the test points are connected if the polarity of the tubes

is reversed, the meter will display "OL". In the circuit, a normal diode should

produce a forward voltage drop of 0.5V to 0.8V; but the reading of the reverse

bias voltage will depend on the change in the resistance value of the other

channels between the two test leads.

ëCapacitance measurement
1. After power on, it will automatically switch to the "AUTO" automatic measurement mode, and then press the SEL button to switch to the capacitance measurement mode. 2. Connect the black test lead and the red test lead to the COM input jack and the INPUT input jack respectively. 3. Use a test pen to measure the capacitance value of the capacitor to be measured at both ends and read the measured value from the LCD.

21

Note
When measuring large capacitances, it will take some time for the reading to stabilize. When measuring polarized capacitors, pay attention to the corresponding polarity to avoid damage to the meter.
ìFrequency measurement
1. After power on, it will automatically switch to the "AUTO" automatic measurement mode, and then press the SEL key to switch to the frequency Hz measurement mode. 2.Connect the black test lead and the red test lead to the COM input jack and the INPUT input jack respectively. 3. Use both ends of the test pen to read the measured value from the LCD display.
í Temperature measurement
1. After power on, it will automatically switch to the "AUTO" automatic measurement mode, and then press the SEL key to switch the measurement mode. 2. Connect the black input terminal of the thermocouple and the red test lead to the COM input jack and the INPUT input jack respectively. Fahrenheit is displayed along with the temperature value. 3. The LCD display reads the measured value.
If there is an inductive impedance in the line, there will be fluctuations affecting the test value or the test data is inaccurate. It is necessary to disconnect the test, and the correct test data will be obtained.
22

5.Technical Indicators

æComprehensive indicators

1000V CAT. III pollution degree: 2

Altitude < 2000 m

Working environment temperature and humidity: 0-40  (<80% RH, not

considered when <10 ).

Storage environment temperature and humidity: -10-60  (<70% RH,

remove the battery).

Temperature coefficient: 0.1 accuracy/°C (<18°C or >28°C).

Maximum allowable voltage between measuring terminal and earth: 1000V

DC or 1000V AC RMS

 Conversion rate: about 3 times / second

Display: LCD display with a maximum of 9999 counts, which is automatically

displayed according to the measurement function

unit symbol.

Overrange indication: LCD will display "OL"

Battery low voltage indication: When the battery voltage is lower than the

normal working voltage,"

"will be displayed.

Indication of input polarity: "-" is displayed automatically.

Power supply: rechargeable lithium battery (3.7V/1000mA) Note: The device

is not available in the power-on state, and the display

"----", at this time, unplug the charger and automatically switch to the normal

measurement mode.

Dimensions: 143mm*75mm*19mm

Weight: about 130g (including battery)

çAccuracy index
Accuracy: soil (reading + word), the warranty period is one year from the date of delivery. Baseline conditions: ambient temperature 18°C to 28°C, relative humidity not greater than 80%.
23

2.1 DC voltage

Range (excluding maximum value)

Resolution

0-10V 10-100V 100-1000V 1000V

0.001V 0.01V 0.1V
1V

Accuracy
±0.8% reading + 3 digits ±0.8% reading + 3 digits ±0.8% reading + 3 digits ±1.2% reading + 3 digits

Maximum input voltage: 1000V DC RMS Minimum measurement voltage: 0.75VDC Press the SEL button to switch the auto range mode in the smart mode

2.2 AC voltage
Range (excluding maximum value) 0-10V
10-100V 100-1000V 1000V

Resolution 0.001V 0.01V 0.1V 1V

Accuracy ±0.8% reading + 3 digits ±0.8% reading + 3 digits ±0.8% reading + 3 digits ±1.2% reading + 3 digits

Maximum input voltage: 1000V DC RMS Minimum measurement voltage: 0.75VDC Frequency response: 50HZ-1KHZ true RMS Press the SEL button to switch the auto range mode in the smart mode

24

2.3 Resistance

Range (excluding maximum value)

Resolution

0-1000

0.1

1k-100k

0.01k

100k-1000k 1M-100M

0.1k 0.01M

Overload protection250V DC/AC

2.4 Beep on and off

Accuracy ±0.8% reading + 3 digits ±0.8% reading + 3 digits ±0.8% reading + 3 digits ±1.2% reading + 3 digits

Function Range Resolution Test Conditions

100

0.1

Resistance not

greater than 50 Open circuit

Built-in buzzer

voltage About 0.4V

sounds continuously

Overload protection250V DC/AC

2.5 Temperature measurement

Range -20-0 1-400 401-1000 -4-32 33.8-752 753.8-1832

Resolution 1 1 1 1 1 1

Accuracy ±5.0% reading + 4 digits ±1.0% reading + 3 digits ±2.0% reading + 5 digits ±5.0% reading + 8 digits ±1.0% reading + 6 digits ±2.0% reading + 10 digits

25

2.6 Capacitance
Range (excluding maximum value) 0-10nF 10-100nF 100-1000nF 1-10F
10-100F 100-1000F
1m-10mF

Resolution 0.001nF 0.01nF 0.1nF 0.001F 0.01F 0.1F 0.001mF

Accuracy ±(4.5% reading + 5digits)

Overload protection250V DC/AC
2.7 Frequency

Range (excluding maximum value)
0-10Hz

Resolution 0.001Hz

10-100Hz

0.01Hz

100-1000Hz 1k-10kHz

0.1Hz 0.001kHz

10k-100kHz

0.01kHz

100k-1000kHz

0.1kHz

Accuracy ±(0.1% reading + 3digits)

1000kHz

1kHz

Input Sensitivity: 1.5V RMS Overload Protection: 250V DC or AC Peak(no more than 10 seconds) frequency measurement
26

2.8 Diodes

Function

Resolution 0.001V

Test Conditions
Forward DC current: about 1mA Open circuit voltage: about 3.2V monitor display diode Approximate value of forward voltage drop

Overload protection250V DC/AC

6.Instrument Maintenance
Regularly clean the meter case with a damp cloth and a small amount of detergent, do not use abrasives or chemical solvents. Dirty or wet input jacks may affect readings. To clean input jacks:
1. Turn off the meter and unplug all test leads from the input jacks. 2. Remove all dirt from the jack. 3. Use a new cotton ball dipped in detergent or lubricant to clean each socket, the lubricant can prevent and moisture related jack contamination.
7.Production Information
See p 28.

27

PCE Instruments contact information

Germany

France

Spain

PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.

Im Langel 26

23, rue de Strasbourg

Calle Mula, 8

D-59872 Meschede

67250 Soultz-Sous-Forets

02500 Tobarra (Albacete)

Deutschland

France

España

Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548

Fax: +49 (0) 2903 976 99 29 Fax: +33 (0) 972 3537 18

Fax: +34 967 543 542

info@pce-instruments.com info@pce-france.fr

info@pce-iberica.es

www.pce-instruments.com/ www.pce-instruments.com/

www.pce-instruments.com/

deutsch

french

espanol

United Kingdom Italy

Turkey

PCE Instruments UK Ltd Trafford House Chester Rd, Old Trafford Manchester M32 0RS United Kingdom Tel: +44 (0) 161 464902 0 Fax: +44 (0) 161 464902 9 info@pce-instruments.co.uk www.pce-instruments.com/ english

PCE Italia s.r.l.

PCE Teknik Cihazlari Ltd.ti.

Via Pesciatina 878 / B-Interno 6 Halkali Merkez Mah.

55010 Loc. Gragnano

Pehlivan Sok. No.6/C

Capannori (Lucca)

34303 Küçükçekmece -

Italia

stanbul

Telefono: +39 0583 975 114 Türkiye

Fax: +39 0583 974 824

Tel: 0212 471 11 47

info@pce-italia.it

Faks: 0212 705 53 93

www.pce-instruments.com/ info@pce-cihazlari.com.tr

italiano

www.pce-instruments.com/

turkish

The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 info@pcebenelux.nl www.pce-instruments.com/ dutch

United States of America

Denmark

PCE Americas Inc.

PCE Instruments Denmark ApS

1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40

Jupiter / Palm Beach

7400 Herning

33458 FL

Denmark

USA

Tel.: +45 70 30 53 08

Tel: +1 (561) 320-9162

kontakt@pce-instruments.com

Fax: +1 (561) 320-9176

www.pce-instruments.com/

info@pce-americas.com

dansk

www.pce-instruments.com/us

28



References

Adobe Illustrator 24.0 (Windows) Adobe PDF library 15.00