User Guide for GENERAC models including: GENERAC, Standby Generators, Liquid-Cooled, Gaseous Engine, QT070, QT080, QT100, QT130, QT150
3 of 9 70 • 80 • 100 • 130 • 150 kW operating data GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both)
Stops unit. Power is removed. Control and charger still operate. Manual . ... Completely wireless and battery powered, Generac's wireless remote.
File Info : application/pdf, 9 Pages, 2.56MB
DocumentDocumentStandby Generators Standby Generators Standby Generators Liquid-Cooled Gaseous Engine 1 of 9 INCLUDES: · Two Line LCD Tri-Lingual Digital NexusTM Controller · Isochronous Electronic Governor · Sound Attenuated Enclosure Standby Power Rating Model QT070 (Aluminum - Bisque) - 70 kW 60 Hz Model QT080 (Aluminum - Bisque) - 80 kW 60 Hz Model QT100 (Aluminum - Bisque) - 100 kW 60 Hz Model QT130 (Aluminum - Bisque) - 130 kW 60 Hz Model QT150 (Aluminum - Bisque) - 150 kW 60 Hz · Closed Coolant Recovery System · Smart Battery Charger · UV/Ozone Resistant Hoses · ±1% Voltage Regulation · Natural Gas or LP Operation · 2 Year Limited Warranty · UL 2200 Listed *Built in the USA using domestic and foreign parts Meets EPA Emission Regulations 70, 100, 130 & 150 kW meet CA/MA emissions requirement with optional catalyst 80 kW not for sale in CA/MA FEATURES ¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. ¡ TEST CRITERIA: PROTOTYPE TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY ¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. ¡ SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ISO 9 0 0 1: 2008 Standby Generators 70 · 80 · 100 · 130 · 150 kW application & engineering data GENERATOR SPECIFICATIONS Type Rotor Insulation Class Stator Insulation Class 2 of 9 Telephone Interference Factor (TIF) Alternator Output Leads 1-Phase Alternator Output Leads 3-Phase Bearings Coupling Excitation System VOLTAGE REGULATION Type Sensing Regulation GOVERNOR SPECIFICATIONS Type Frequency Regulation Steady State Regulation Synchronous H H <50 4 wire 6 wire (70, 80 & 150 kW) or 12 wire (100 & 130 kW) Sealed Ball Flexible Disc (70, 80 & 150 kW) or Gear Drive (100 & 130 kW) Brushless Electronic Single Phase ± 1% Electronic Isochronous ± 0.25% ENGINE SPECIFICATIONS: 80 kW Make Model Cylinders Displacement (Liters) Bore (in/mm) Stroke (in/mm) Compression Ratio Intake Air System Lifter Type Generac V-Type 8 5.4 3.55/90.2 4.17/105.9 9:1 Naturally Aspirated Hydraulic ENGINE SPECIFICATIONS: 70, 100, 130 & 150 kW Make Generac Model V-Type Cylinders 10 Displacement (Liters) 6.8 Bore (in/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ELECTRICAL SYSTEM Battery Charge Alternator Static Battery Charger Recommended Battery (battery not included) System Voltage 12 Volt 30 Amp 2 Amp Group 24F, 525 CCA (70, 80 & 150 kW) or Group 27F, 700 CCA (100 & 130 kW) 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather protective enclosure Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. ENGINE LUBRICATION SYSTEM Oil Pump Type Oil Filter Type Crankcase Capacity (qt/l) ENGINE COOLING SYSTEM Type Water Pump Fan Speed (rpm) Fan Diameter (in/mm) Fan Mode FUEL SYSTEM Fuel Type Carburetor Secondary Fuel Regulator Fuel Shut Off Solenoid Operating Fuel Pressure Gear Full flow spin-on cartridge 5/4.7 (70, 100, 130 & 150 kW) or 6/5.7 (80 kW) Closed Belt driven 2300 - 70 kW 2174 - 80 kW 1670 - 100 kW 1950 - 130 kW 2200 - 150 kW 22/558.8 (70 kW) or 26/660.4 (80, 100, 130 & 150 kW) Pusher (70 kW) or Puller (80, 100, 130 & 150 kW) Natural gas, propane vapor Down Draft Standard Standard 11-14" water column/21-26 mm HG (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271) Standby Generators 70 · 80 · 100 · 130 · 150 kW GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG 120/240 V, 1Ø, 1.0 pf 67 120/208 V, 3Ø, 0.8 pf 70 QT070 120/240 V, 3Ø, 0.8 pf 70 277/480 V, 3Ø, 0.8 pf 70 120/240 V, 1Ø, 1.0 pf 77 120/208 V, 3Ø, 0.8 pf 80 QT080 120/240 V, 3Ø, 0.8 pf 80 277/480 V, 3Ø, 0.8 pf 80 120/240 V, 1Ø, 1.0 pf 100 120/208 V, 3Ø, 0.8 pf 100 QT100 120/240 V, 3Ø, 0.8 pf 100 277/480 V, 3Ø, 0.8 pf 100 120/240 V, 1Ø, 1.0 pf 130 120/208 V, 3Ø, 0.8 pf 130 QT130 120/240 V, 3Ø, 0.8 pf 130 277/480 V, 3Ø, 0.8 pf 130 120/240 V, 1Ø, 1.0 pf 144 120/208 V, 3Ø, 0.8 pf 150 QT150 120/240 V, 3Ø, 0.8 pf 150 277/480 V, 3Ø, 0.8 pf 150 Amp LPG 292 243 211 105 333 278 241 120 417 347 301 150 542 451 391 195 625 520 451 225 kW Nat. Gas 64 67 67 67 77 80 80 80 89 94 94 94 117 122 122 122 136 142 142 142 operating data Amp Nat. Gas CB Size (Both) 267 300 232 300 201 250 101 125 3 of 9 333 400 278 300 240 300 120 150 371 450 326 400 283 350 141 175 488 600 423 500 367 450 183 225 567 700 493 600 427 500 214 250 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION QT070 QT080 QT100 QT130 QT150 120/240 V, 1Ø 120/208 V, 3Ø 120/240 V, 3Ø 277/480 V, 3Ø 120/240 V, 1Ø 120/208 V, 3Ø 120/240 V, 3Ø 277/480 V, 3Ø 120/240 V, 1Ø 120/208 V, 3Ø 120/240 V, 3Ø 277/480 V, 3Ø 120/240 V, 1Ø 120/208 V, 3Ø 120/240 V, 3Ø 277/480 V, 3Ø 120/240 V, 1Ø 120/208 V, 3Ø 120/240 V, 3Ø 277/480 V, 3Ø Voltage Dip @ < .4 pf 15% 30% 129 356 194 471 168 408 83 201 174 435 186 466 161 404 70 175 150 413 186 452 161 392 107 261 236 648 364 885 315 767 161 390 486 1214 534 1334 463 1156 250 624 Note: Fuel pipe must be sized for full load. For Btu content, multiply gal/hr x 90950 (LP) or ft3/hr x 1000 (NG). QT070 QT080 QT100 QT130 QT150 Exercise cycle 25% of rated load 50% of rated load 75% of rated load 100% of rated load Exercise cycle 25% of rated load 50% of rated load 75% of rated load 100% of rated load Exercise cycle 25% of rated load 50% of rated load 75% of rated load 100% of rated load Exercise cycle 25% of rated load 50% of rated load 75% of rated load 100% of rated load Exercise cycle 25% of rated load 50% of rated load 75% of rated load 100% of rated load Natural Gas (ft³/hr) (m³/hr) 110 3.1 260 7.4 500 14.2 696 19.8 1020 29 95 2.7 549.5 15.6 784.4 22.2 1024.8 29.0 1252.2 35.5 130 3.7 371 10.5 713 20.3 991 28.2 1260 35.8 135 3.8 482 13.7 927 26.3 1292 36.7 1786 50.8 155 4.4 556 15.8 1070 30.4 1491 42.4 2061 58.6 For megajoule content, multiply l/hr x 25.35 (LP) or m³/hr x 37.26 (NG). Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. (gal/hr) 1.2 2.85 5.46 7.62 11.17 1.4 3.46 6.62 9.24 12.78 1.4 4.1 7.9 11 13.9 1.4 5.3 10.3 14.3 19.8 1.7 6.09 11.72 16.33 22.57 Propane (l/hr) 4.6 10.8 20.8 29.1 42.6 5.51 13.11 25.1 34.96 48.38 5.4 15.5 29.8 41.5 52.6 5.7 20 38.7 54 74.6 6.5 23.2 44.7 62.3 86.1 (ft3/hr) 44 104 200 280 411 53 126 241 336 465 52 149 287 400 507 55 193 373 520 719 63 224 431 600 830 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. Standby Generators 70 · 80 · 100 · 130 · 150 kW operating data ENGINE COOLING Air flow (inlet air including alternator and combustion air in ft³/min) System coolant capacity (gal/liters) 4 of 9 Heat rejection to coolant (BTU/hr) Maximum operation air temperature on radiator (°C/°F) Maximum ambient temperature (°C/°F) 70 kW 5200/147.2 4.5/17 287,000/302.8 80 kW 5300/150.1 4/15.1 316,000/333.4 100 kW 5500/155.7 4.5/17 342,000/360.8 60/150 50/140 130 kW 6450/182.6 4.5/17 496,000/523.3 150 kW 7800/220.9 4.5/17 568,000/599.3 COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm) 205/5.8 143/4 262/7.4 336/9.5 410/11.6 SOUND EMISSIONS Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 64 65 68 69 66 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 72 74 72 75 79 *Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) Exhaust temperature at muffler outlet (°C/°F) 557/15.8 477/890 720/20.4 796/1465 888/25.1 516/960 1119/31.7 521/970 1535/43.5 593/1100 ENGINE PARAMETERS Rated Synchronous rpm 1800 3600 2300 2970 3600 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration ...........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (70,100,130 & 150).................................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (80 kW) ................................................................................................ 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES 2-Line Plain Text LCD Display ........................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto ..............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser Off...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds ............................................................................................................................................................ Standard Engine Start Sequence..................................................................................................................... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up..................................................................................................................................................................................................................... 5 sec Engine Cool-Down ..................................................................................................................................................................................................................1 min Starter Lock-out ................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger ........................................................................................................................................................................................................ Standard Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................ Standard Automatic Low Oil Pressure Shutdown ............................................................................................................................................................................... Standard Overspeed Shutdown .............................................................................................................................................................................................. Standard, 72 Hz High Temperature Shutdown............................................................................................................................................................................................... Standard Overcrank Protection .......................................................................................................................................................................................................... Standard Safety Fused...................................................................................................................................................................................................................... Standard Failure to Transfer Protection.............................................................................................................................................................................................. Standard Low Battery Protection........................................................................................................................................................................................................ Standard 50 Event Run Log............................................................................................................................................................................................................... Standard Future Set Capable Exerciser.............................................................................................................................................................................................. Standard Incorrect Wiring Protection................................................................................................................................................................................................. Standard Internal Fault Protection ..................................................................................................................................................................................................... Standard Common External Fault Capability...................................................................................................................................................................................... Standard Governor Failure Protection................................................................................................................................................................................................ Standard Standby Generators 70 · 80 · 100 · 130 · 150 kW available accessories Model # G006463-4 G006478-0 G005632-1 - 70, 80 & 150 kW G005633-0 - 100 & 130 kW G005620-0 - 70, 100 & 130 kW G006204-0 - 80 kW G005667-0 - 150 kW Product Mobile LinkTM Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness 5 of 9 Adapter Kit required. Available in the U.S. only. Harness Adapter Kit The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile LinkTM. Cold Weather Kit If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. Extreme Cold Weather Recommended where the temperature regularly falls below 32 °F (0 °C) Kit for extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. G005703-0 G005660-0 - 70, 100, 130, and 150 kW G006915-0 - 80 kW G006664-0 G006665-0 G006873-0 G007005-0 G006510-0 Paint Kit If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Scheduled Maintenance Kit The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators. Completely wireless and battery powered, Generac's wireless remote Local Wireless Monitor monitor provides you with instant status information without ever leaving the house. Wireless Remote Extension Harness Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater. Smart Management Module (50 Amps) Wi-Fi LP Fuel Level Monitor E-Stop Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system. The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. E-stop allows for immediate fuel shutoff and generator shutdown in the event of anemergency. Standby Generators 70 · 80 · 100 · 130 · 150 kW Drawing #0H7452-D 6 of 9 (IF EQUIPPED) interconnections 70 kW installation layout Drawing #0F6287-E 7 of 9 DIMENSIONS: MM [INCH] Standby Generators 80 kW Drawing #0L3178-B 8 of 9 Standby Generators RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) BATTERY 12V GROUP 26 NEGATIVE GROUND P/N: 058208 A_1 1422 [56] CENTER OF GRAVITY SEE NOTE 5 AIR INTAKE (BOTH SIDES) REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP LOW VOLTAGE AREA ONLY 91 TOP VIEW [3.6] 206 [8.1] 872 [34.3] SERVICE ITEM OIL FILL CAP OIL DIP STICK OIL FILTER OIL DRAIN HOSE RADIATOR DRAIN HOSE AIR CLEANER ELEMENT SPARK PLUGS MUFFLER FAN BELT BATTERY 5.4L LEFT DOOR LEFT DOOR LEFT DOOR RIGHT DOOR LEFT DOOR EITHER DOOR EITHER DOOR SEE NOTE 12 EITHER DOOR RIGHT DOOR REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. STUB-UP AREA SEE NOTE 4 128 [5.0] 86 [3.4] EXHAUST MUFFLERS & FAN BELT ENCLOSED WITHIN SEE NOTE 12 CONTROL PANEL BATTERY CHARGER IS ENCLOSED WITHIN. NOTES: 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1241 (49") WIDE 3228 (127") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. INSIDE STUB-UP AREA FOR AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (.5 AMP MAX) CONNECTION AND ACCESS TO TRANSFER SWITCH CONTROL WIRES. REMOVE FRONT COVER FOR ACCESS. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 24 INCHES H2O. 8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 9. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 10. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 12. REMOVE EITHER LEFT OR RIGHT HAND SIDE PANEL TO ACCESS EXHAUST MUFFLERS AND FAN BELT. 13. FIELD CUT HOLE IS ONLY REQUIRED FOR MOUNTING OF GENERATOR ON AN EXISTING PAD. VISE ACTION LATCH, ONE PER DOOR, TWO LIFT-OFF DOORS PER SIDE OF GENERATOR. RADIATOR/ EXHAUST DISCHARGE AIR 68 [2.7] 47 [1.8] A A 1521 [59.9] OVERALL HEIGHT 1777 [70.0] 51 [2.0] 2832 [111.5] LEFT SIDE VIEW FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING STUB-UP AREA FIELD CUT FOR OUTSIDE CONDUIT CONNECTION ONLY SEE NOTE 13 LIFTING PROVISION (4 PLACES) SEE NOTES 5, 8 AND CENTER OF GRAVITY DIMENSIONS. 935 [36.8] REAR VIEW WEIGHT DATA ENGINE/KW ENCLOSURE MATERIAL WEIGHT GENSET ONLY KG [LBS] WEIGHT SHIPPING SKID KG [LBS] SHIPPING WEIGHT KG [LBS] 5.4L/80KW AL 925 [2035] 79 [175] 1004 [2210] DIMENSIONS: MM [INCH] A A RIGHT SIDE VIEW installation layout Standby Generators 100 · 130 · 150 kW installation layout Drawing #0H4105-B 9 of 9 DIMENSIONS: MM [INCH] Generac Power Systems, Inc. · S45 W29290 HWY. 59, Waukesha, WI 53189 · generac.com ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0199370SBY-M 05/31/17Adobe InDesign CC 2017 (Windows) Adobe PDF Library 15.0