EcoDim ECO-DIM.06 Z-Wave Plug-in Dimmer
Specifications
- Input Voltage: 220-240 V
- Frequency: 50Hz
- Maximum Wattage: 100W
- Minimum Wattage: 0W
- Dimming Technology: Phase cut-off (Trailing Edge R,C)
- Dimmable LED Lamps: 0-100W
- Bulbs with Electronic Transformers: 5-150VA
- Halogen and Incandescent Bulbs: 5-150VA
Installation
- Plug the socket dimmer into the wall socket.
- Insert the plug of the lamp into the dimmer's socket.
- Press the dimmer button on the dimmer unit.
- Turn the dimmer knob to adjust the lamp brightness.
Key Features
- ✔️ Compatible with any Z-Wave or Z-Wave plus controller.
- ✔️ Power Consumption meter.
- ✔️ Voice support (Amazon Alexa & Google Assistant / Homey).
- ✔️ Supports Repeater Role, Firmware OTA, and SmartStart.
- ✔️ Suitable for 0-100W LED.
- ✔️ Suitable for all well-known brands of cover frames.
- ✔️ Optimal dimming and light stability.
- ✔️ MIN light adjustment options.
- ✔️ Suitable for 90% of all LEDs.
- ✔️ Soft start system.
- ✔️ Noiseless dimming.
Operation
MIN Brightness Adjustment
To ensure optimal performance, adjust the minimum brightness level. When the light is on at the previously set minimum level, turn the potentiometer counter-clockwise to decrease or clockwise to increase the minimum brightness to your preference. Avoid flickering.
Factory Reset
To reset the device to factory settings, press and hold the reset button for 5 seconds. The indicator light will turn red for 10 seconds, indicating the reset is complete. This procedure should only be used if the primary controller is inoperable. All configurations will be removed.
Inclusion to a Z-Wave Network
- Remove the device from any previous Z-Wave network if it was already added.
- From your Z-Wave Controller interface, choose to add a lighting device and enter pairing mode.
- Double-press the reset button.
- The indicator light will start blinking blue and will stay solid for 10 seconds upon successful pairing. (Timeout: 15 minutes)
Exclusion from a Z-Wave Network
Method 1: Use your Z-Wave hub interface to delete or reset the device as instructed by the hub manufacturer.
Method 2: Remove from the device directly:
- Press the reset button for 5 seconds.
- The indicator light will start blinking purple and will stay solid for 10 seconds when removal is completed. (Timeout: 3 minutes)
Z-Wave Technical Details
Security and Non-Security Features
The dimmer functions identically as a security and non-security device. When included in an S0 or S2 Z-Wave network, it supports S0/S2 unauthenticated and authenticated classes, along with supported Command Classes (CCs).
Command Classes
| Network Type | Included Non-Secure Network Command Classes | Included Secure Network Command Classes | Security Supported Report Command Classes |
|---|---|---|---|
| Non-secure | COMMAND_CLASS_ZWAVEPLUS_INFO_V2, COMMAND_CLASS_VERSION_V2, COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2, COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1, COMMAND_CLASS_ASSOCIATION_V2, COMMAND_CLASS_POWERLEVEL_V1, COMMAND_CLASS_SWITCH_MULTILEVEL_V2, COMMAND_CLASS_CONFIGURATION_V1, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4, COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1, COMMAND_CLASS_SECURITY_2_V1, COMMAND_CLASS_SECURITY_V1, COMMAND_CLASS_TRANSPORT_SERVICE_V2, COMMAND_CLASS_SUPERVISION_V1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2, COMMAND_CLASS_TRANSPORT_SERVICE_V2, COMMAND_CLASS_SECURITY_2_V1, COMMAND_CLASS_SECURITY_V1, COMMAND_CLASS_SUPERVISION_V1 | COMMAND_CLASS_VERSION_V2, COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2, COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1, COMMAND_CLASS_ASSOCIATION_V2, COMMAND_CLASS_POWERLEVEL_V1, COMMAND_CLASS_SWITCH_MULTILEVEL_V2, COMMAND_CLASS_CONFIGURATION_V1, COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4, COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 |
Z-Wave Plus Info Command Report
| Parameter | Value |
|---|---|
| Z-Wave Plus Version | V1 |
| Role Type | ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON |
| Node Type | ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE |
| Installer Icon Type | ICON_TYPE_GENERIC_LIGHT_DIMMER_SWITCH |
| User Icon Type | ICON_TYPE_GENERIC_LIGHT_DIMMER_SWITCH |
Association Command
The dimmer supports 1 association group:
- Group 1: Device Reset Locally, Switch Multilevel Report (sent when dimmer state changes).
Basic Command
Basic Command Class (CC) maps to Multilevel CC. Basic Set values correspond to Multilevel Switch Set values (e.g., 255 maps to 255, 0 maps to 0, 1-99 maps to 1-99). Basic Get/Report maps to Multilevel Switch Get/Report.
Configuration Parameters
The dimmer offers advanced configuration settings accessible via the main controller's interface. Key parameters include:
- Parameter 0x02 (State After Power Restored): Configures the switch's state after power failure (0=Off, 1=On, 2=Return to previous level).
- Parameter 0x01 (Notification when Load status change): Enables notifications to associated devices (Group Lifeline) when the dimmer load status changes (0=Disabled, 1=Send Switch Multilevel Report, 2=Send report only when status not changed by Z-Wave command).
Z-Wave SmartStart and QR Code
DSK (Device Specific Key)
The DSK is a unique identifier for the device. It can be obtained by scanning the QR code on the device or packaging with an Android phone. The DSK is used for SmartStart inclusion.
Quick Response Code (QR Code)
The QR code contains the first 16 bytes of the ECDH Public Key and other information. The term "DSK" in this document refers to the Full DSK, or combinations involving the DSK and QR Code/Pin Code.
SmartStart Inclusion
Smart Start products can be added to a Z-Wave network by scanning the Z-Wave QR code with a controller that supports SmartStart recording. Once the DSK is added to the controller's SmartStart function list and the dimmer is powered on, it will automatically join the network within 10 minutes.
Supported Hubs/Platforms
The dimmer is suitable for most Z-Wave hubs and apps, including:
- ✔️ Fibaro
- ✔️ SmartThings
- ✔️ Vera
- ✔️ Google Home
- ✔️ Amazon Alexa
- ✔️ Wink
- ✔️ Homee
- ✔️ Futurehome
- ✔️ Homey
Refer to your hub's manual for specific instructions.
Important Notes
Please note:
- For indoor use only.
- Input voltage must be 220-240V.
- The dimmer is voltage-free when unplugged.
- Do not cover the dimmer when in use.